TÜV NORD Hochfrequenztechnik GmbH & Co. KG
Waltherstraße 49-51, 51059, Köln, Germany
Visit website- Accredited standards
- 35
- DAKKS certificates
- 4
- Site in our directory
- 1
What this lab is accredited for
Our reading of the DAKKS scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 35 standard numbers and the 26 official names we hold. When no standard matches, it searches the method text of every scope line.
IEC 61000 series11
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 61000-4-13Electromagnetic compatibility (EMC) - Part 4-13: Testing and measurement techniques - Harmonics and interharmonics including mains signalling at a.c. power port, low frequency immunity tests
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments
IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
IEC8
IEC 60065
IEC 60950-1Information technology equipment - Safety - Part 1: General requirements
IEC 61010-1Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
IEC 61547Equipment for general lighting purposes - EMC immunity requirements
IEC 62311Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz to 300 GHz)
IEC 62368-1Audio/video, information and communication technology equipment - Part 1: Safety requirements
IEC 62369-1
IEC 62479Assessment of the compliance of low power electronic and electrical equipment with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz)
CISPR5
CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission
CISPR 14-2Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard
CISPR 22Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement
CISPR 24Information technology equipment - Immunity characteristics - Limits and methods of measurement
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements
EN4
EN 50083-2
EN 50130-4Alarm systems - Part 4: Electromagnetic compatibility - Product family standard: Immunity requirements for components of fire, intruder, hold up, CCTV, access control and social alarm systems
EN 50293
EN 50364
IEC 61326 series3
IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
IEC 61326-2-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-1: Particular requirements - Test configurations, operational conditions and performance criteria for sensitive test and measurement equipment for EMC unprotected applications
IEC 61326-2-2Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-2: Particular requirements - Test configurations, operational conditions and performance criteria for portable testing, measuring and monitoring equipment used in low-voltage distribution systems
Other standards4
ANSI C63.10
ANSI C63.26
DIN 61010
RSS-170
DIN EN 61000-3-3: 2014-03; DIN EN 61326-1: 2013-07; DIN EN 61326-2-1: 2013-08; DIN EN 61326-2-2: 2013-08; DIN EN 61547: 2010-03
DIN EN 61000-4-2: 2009-12; DIN EN 61000-4-3: 2011-04; DIN EN 61000-4-4: 2013-04; DIN EN 61000-4-5: 2015-03; EN 61000-4-2
DIN EN 61000-4-6: 2014-08; DIN EN 61000 4-8 : 2010-11; DIN EN 61000-4-11: 2005-02; DIN EN 61000-4-13: 2010-04; DIN EN 61000-6-1: 2007-10
DIN EN 61000-6-3: 2011-09; DIN EN 61000-6-4: 2011-09; DIN EN 50083-2:2012; DIN EN 50130-4: 2012-02; DIN EN 50293:2013
DIN EN 60950 -1: 2014-08 Einrichtungen der Informationstechnik - Sicherheit - Teil 1; DIN EN 60065:2015 -11; isolierter Wickeldrähte ohne Zwischenlage nach Anhang U SEB DIN EN 60065:2015 -11; EN 60950
DIN EN 62368 -1: 2016-05; DIN 61010; VDE 0868-1; EN 61010-; EN 62368
DIN EN 50364:2010 -11; DIN EN 62311:2008 -09; DIN EN 62369 -1 :2010 - 03 Er mittlun g der Ex po sit io n vo n Per son en gegenüber elektromagnetischen Feldern im Frequenzbereich 0 GHz bis 300 GHz durch Geräte mit kurzer Reichweite für verschiedene Anwendungen - Teil 1; DIN EN 62479:2011 -09
DIN EN IEC 62368 -1: 2021 -05; VDE 0868-1; IEC 62368; IEC 62368-
DIN EN 55014-1: 2012-05; DIN EN 55014-2: 2014-01; DINEN 55015: 2014-03; DIN EN 55022: 2011-12; DIN EN 55024: 2011-09 Einrichtungen der Informationstechnik - Störfestigkeitseigenschaften-Grenzwerte und Mess-verfahren EMV DIN EN 55032: 2012-12
ANSI C63.4 -2014; ANSI C63.4a-2017; FCC MP -5-(February 1986 ); ANSI C63.10 -2013; ANSI C63.10-2020; KDB Publication 789033; KDB Publication 987594; FCC KDB Publication 905462 D02 U-NII DFS Compliance Procedures New Rules v02 (April 8, 2016); ANSI/TIA -603 -E-2016; ANSI/TIA-102.CAAA-E-2016; ANSI C63.26-2015; KDB Publication 971168
ANSI/TIA -603 -E-2016; ANSI/TIA-102.CAAA-E-2016; ANSI C63.26-2015; KDB Publication 653005
RSS -139; RSS -140; RSS -141; RSS -142; RSS-170; RSS -181; RSS -194; RSS -195
Read from the scope as published by DAKKS. Register refreshed 2026-11-20.
Scope as published by DAKKS
42 lines
ISO/IEC 17025
ActiveD-PL-12053-01-00
ISO/IEC 17025
ActiveD-PL-12053-01-01
ISO/IEC 17025
ActiveD-PL-12053-01-02
ISO/IEC 17025
ActiveD-PL-12053-01-03
Location
Labs with overlapping accredited scope in Germany
- PHOENIX TESTLABBlomberg · ~176 kmDAKKSShares 4 accredited test methodsANSI C63.10-2020ANSI C63.26-2015EN 61000-4-2
- AKUVIB Engineering and TestingBochum · ~55 kmDAKKSShares 3 accredited test methodsEN 61000-4-2EN ISO 9001DIN
- IBL-LabSt. Ingbert · ~190 kmDAKKSShares 3 accredited test methodsANSI C63.10-2020ANSI C63.26-2015EN ISO 9001
- eco-INSTITUT GermanyKöln · ~5 kmDAKKSShares 2 accredited test methodsEN ISO 9001DIN
- TÜV Rheinland Industrie Service GmbH Prüflaboratorium für Ex-SchutzKöln · ~8 kmDAKKSShares 2 accredited test methodsEN ISO 9001DIN
Accreditation data refreshed from the DAKKS register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.