Autoliv AAM

Brigham Facility, Metrology Laboratory, 250 American Way, 84302, Brigham City, UT, United States

Visit website
A2LA 403.15ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
3
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 3 scope lines.

A2LA certificate 403.15 · 3 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017-to 11 in
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 403.15) 07/23/2025 Page 2 of 2 II. Dimensional Testing/Calibration4 Parameter/Equipment Range CMC2, 3 (±) Comments Length – 3D X – Axis Y – Axis Z – Axis Up to 24 in Up to 38 in Up to 22 in (200 + 4L) µin CMM: Mitutoyo Crysta Apex S 7106 III. Mechanical Parameter/Equipment Range CMC2, 5 (±) Comments Torque – Tools/Wrenches (4 to 50) lbf·in (30 to 400) lbf·in (80 to 1000) lbf·in (20 to 250) lbf·ft (50 to 600) lbf·ft 1 % 1 % 1 % 1.2 % 1.2 % Torque system CDI – 600 TL w/ transducers, CDI 2000-400-02 and 2000-12-02 ____________________________________________ 1 This laboratory does not offer commercial calibration services. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches. 4 This laboratory meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program for the types of dimensional tests listed above and is considered equivalent to that of a calibration. 5 In the statement of CMC, percentages are percentage of reading, unless otherwise indicated. 6 This scope meets A2LA’s P112 Flexible Scope Policy.
3ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Brigham Facility, Metrology Laboratory, 250 American Way, Brigham City, UT, 84302, US