Aptiv (China) Technology Company
118 De Lin Road, Wai Gao Qiao Pilot Free Trade Zone, Shanghai, 200131, People's Republic of China, Shanghai, China
- Accredited standards
- 15
- A2LA certificates
- 2
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 15 standard numbers and the 15 official names we hold. When no standard matches, it searches the method text of every scope line.
IEC 60068 series4
IEC 60068-2-1Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 60068-2-6Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
IEC 60068-2-27Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
IEC 60068-2-64Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance
ISO 11452 series4
ISO 11452-2Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 2: Absorber-lined shielded enclosure
ISO 11452-4Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 4: Harness excitation methods
ISO 11452-8Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 8: Immunity to magnetic fields
ISO 11452-9Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 9: Portable transmitters
ISO 16750 series4
ISO 16750-2Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 2: Electrical loads
ISO 16750-3Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 3: Mechanical loads
ISO 16750-4Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 4: Climatic loads
ISO 16750-5Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 5: Chemical loadsSome materials
Limits written next to it
Fluids Compatibility ISO 16750-5 (only DD, DC, CC)
ISO3
ISO 7637-2Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only
ISO 7637-3Road vehicles - Electrical disturbances from conduction and coupling - Part 3: Electrical transient transmission by capacitive and inductive coupling via lines other than supply lines
ISO 10605Road vehicles - Test methods for electrical disturbances from electrostatic discharge
ISO/IEC 17025: 2017; ISO 16750-4 Sections 5; ISO 16750-4 Section 5; IEC 17025; IEC 60068-2-1
ISO 16750-3 Section 4; ISO 16750-5; IEC 60068-2-6; IEC 60068-2-64; IEC 60068-2-27
CISPR 25 (2002, 2008); CISPR 25 (2016, 2021); GMW3097 (2015, 2019, 2022); ISO 7637-2 (2004, 2011); ISO 7637-3 (2007, 2016); ISO 11452-4 (2005, 2011); ISO 11452-4 (2020); ISO 10605 (2001, 2008, 2023); ISO 10605 (AMD 1 2014); ISO 11452-2 (2004, 2019)
ISO 11452-8 (2007, 2015); GMW3097 (2015, 2019, 2022), Section 3.4.5; ISO 11452-9 (2012, 2021); GMW3097 (2015, 2019, 2022), Section 3.4.4; ISO 16750-2 (2012) Sections 4.2 to 4.12; ISO 16750-2 (2023) Sections 4.2 to 4.12; GMW3172 (2015); GMW3172 (2018); GMW3172 Section 8.2.1; GMW3172 Section 8.2.2; GMW3172 Section 8.2.3; GMW3172 Section 8.2.4; GMW3172 Section 9.2.1; GMW3172 Section 9.2.2; GMW3172 Section 9.2.3; GMW3172 Section 9.2.4; GMW3172 Section 9.2.5; GMW3172 Section 9.2.6; GMW3172 Section 9.2.7; GMW3172 Section 9.2.8; GMW3172 Section 9.2.9; GMW3172 Section 9.2.10; GMW3172 Section 9.2.11; GMW3172 Section 9.2.12; GMW3172 Section 9.2.13; GMW3172 Section 9.2.14; GMW3172 Section 9.2.15; GMW3172 Section 9.2.16; GMW3172 Section 9.2.17; GMW3172 Section 9.2.18; GMW3172 Section 9.2.19
Read from the A2LA scope documents we downloaded on 2025-12-02 and 2026-10-27. Register refreshed 2026-11-06.
Scope as published by A2LA
6 lines
ISO/IEC 17025
Active3719.01
The scope document we hold says it is valid until 2027-01-31.
Accredited scope, certificate 3719.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | CISPR 25 (2002, 2008); CISPR 25 (2016, 2021); GMW3097 (2015, 2019, 2022); ISO 7637-2 (2004, 2011); ISO 7637-3 (2007, 2016); ISO 11452-4 (2005, 2011); ISO 11452-4 (2020); ISO 10605 (2001, 2008, 2023); ISO 10605 (AMD 1 2014); ISO 11452-2 (2004, 2019) | automotive components | - |
| 2 | ISO 11452-8 (2007, 2015); GMW3097 (2015, 2019, 2022), Section 3.4.5; ISO 11452-9 (2012, 2021); GMW3097 (2015, 2019, 2022), Section 3.4.4; ISO 16750-2 (2012) Sections 4.2 to 4.12; ISO 16750-2 (2023) Sections 4.2 to 4.12; GMW3172 (2015); GMW3172 (2018); GMW3172 Section 8.2.1; GMW3172 Section 8.2.2; GMW3172 Section 8.2.3; GMW3172 Section 8.2.4; GMW3172 Section 9.2.1; GMW3172 Section 9.2.2; GMW3172 Section 9.2.3; GMW3172 Section 9.2.4; GMW3172 Section 9.2.5; GMW3172 Section 9.2.6; GMW3172 Section 9.2.7; GMW3172 Section 9.2.8; GMW3172 Section 9.2.9; GMW3172 Section 9.2.10; GMW3172 Section 9.2.11; GMW3172 Section 9.2.12; GMW3172 Section 9.2.13; GMW3172 Section 9.2.14; GMW3172 Section 9.2.15; GMW3172 Section 9.2.16; GMW3172 Section 9.2.17; GMW3172 Section 9.2.18; GMW3172 Section 9.2.19 | - | - |
| 3 | ISO/IEC 17025:2017 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
ISO/IEC 17025
Active3719.02
The scope document we hold says it is valid until 2027-01-31.
Accredited scope, certificate 3719.02
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025: 2017; ISO 16750-4 Sections 5; ISO 16750-4 Section 5; IEC 17025; IEC 60068-2-1 | Air | - |
| 2 | ISO 16750-3 Section 4; ISO 16750-5; IEC 60068-2-6; IEC 60068-2-64; IEC 60068-2-27 | - | - |
| 3 | ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Labs with overlapping accredited scope in China
- DEKRA IST Reliability ServicesJiangsu Province, People’s Republic of ChinaA2LAShares 2 accredited test methodsIEC 60068-2-1IEC 60068-2-6
- DEKRA Testing and Certification (Shanghai)ShanghaiA2LAShares 1 accredited test methodIEC 60068-2-1
- SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen BranchShenzhen, GuangdongA2LAShares 1 accredited test methodIEC 60068-2-1
- TUV Rheinland (Suzhou) Co.,Taicang City, JiangsuA2LAShares 1 accredited test methodIEC 60068-2-1
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.