Registers refreshed 2026-11-08.See refresh dates
United States

Cross Technologies, Inc - LYNCHBURG

171 Vista Centre Drive, 24551, Forest, VA, United States

Visit website
A2LA 1741.25ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
13
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 13 scope lines.

A2LA certificate 1741.25 · 13 lines

LineMethodMatrixRange
1-Gage block
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.25) 11/03/2025 Page 1 of 12 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 CROSS TECHNOLOGIES, INC DBA CROSS 171 Vista Centre Drive Forest, VA 24551 Connie Foster Phone: 800 327 7727 CALIBRATION Valid To: November 30, 2027 Certificate Number: 1741.25 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 5: I. Chemical Parameter/Equipment Range CMC2 (±) Comments pH Meters3 4 pH 7 pH 10 pH 0.024 pH units 0.024 pH units 0.024 pH units Standard pH solutions Conductivity Meters3 10 μS/cm 100 µS/cm 1000 µS/cm 10000 µS/cm 0.63 μS/cm 2.2 µS/cm 5.2 µS/cm 46 µS/cm Standard conductivity solutions II. Dimensional Parameter/Equipment Range CMC2, 4 (±) Comments Pin Gage3 – Class Z & ZZ Up to 1 in 41 µin Micrometer Calipers3 Up to 40 in (6.9 + 2.8L) µin + 0.6R Gage blocks
to 1 in
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.25) 11/03/2025 Page 2 of 12 Parameter/Equipment Range CMC2, 4 (±) Comments Micrometers3 – Outside Up to 40 in (6.9 + 2.8L) µin + 0.6R Gage blocks Linear Indicators3 – Dial & Test Up to 4 in (6.7 + 3L) µin + 0.6R Gage blocks Thickness/Snap Gages3 Up to 4 in (6.9 + 2.8L) µin + 0.6R Gage blocks Height Gages3 Up to 48 in (6.1 + 2.6L) µin + 0.6R Gage blocks, surface plate Steel Rules3 Up to 72 in (4.8 + 9.2L) μin + 0.6R Gage blocks Tape Measures3 Up to 25 ft (4.8 + 9.2L) μin + 0.6R Gage blocks Angle Indicators & Protractors 3 0.25°, 0.5°, 1°, 2°, 3°, 4°, 5°, 10°,15° 20°, 25, 30°, 45°, 60°, 90° Up to 60° 0.03° 0.03° Angle block set Sine bar Feeler Gages3 Up to 1 in 41 µin Digital micrometer
to 40 in
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.25) 11/03/2025 Page 3 of 12 III. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 7,9 (±) Comments DC Voltage – Measure3 (0 to 100) mV (0.1 to 1.0) V (1 to 10) V (10 to 100) V (100 to 1000) V Up to 6 kV 63 µV/V + 3.5 µV 49 µV/V + 7 µV 43 µV/V + 50 µV 55 µV/V + 600 µV 55 µV/V + 10 mV 1.2 % Keysight 34461A Fluke 80K-6 & DMM DC Voltage – Generate3 (0 to 330) mV 330 mV to 3.3 V (3.3 to 33) V (33 to 330) V (100 to 1020) V 25 µV/V + 1 µV 14 µV/V + 2 µV 15 µV/V + 15 µV 22 µV/V + 150 µV 22 µV/V + 1.5 mV Fluke 5522A DC Current – Measure3 (1 to 10) mA (10 to 100) mA (0.1 to 1.0) A (1 to 50) A 0.098 % 0.067 % 0.014 % + 0.1 mA 0.25 % Keysight 34461A Empro shunt w/ HP DMM DC Current – Generate3 (0 to 330) µA (0 to 3.3) mA (0 to 33) mA (0 to 330) mA (0 to 1.1) A (1.1 to 3) A (0 to 11) A (11 to 21) A 0.018 % + 0.02 µA 0.012 % + 0.05 µA 0.013 % + 0.25 µA 0.015 % + 2.5 µA 0.025 % + 40 µA 0.046 % + 40 µA 0.06 % + 500 µA 0.12 % + 750 µA Fluke 5522A Resistance – Measure3 (0 to 100) Ω (0.1 to 1) kΩ (1 to 10) kΩ (10 to 100) kΩ (0.1 to 1) MΩ (1 to 10) MΩ (10 to 100) MΩ 0.013 % + 4 mΩ 0.012 % + 10 mΩ 0.013 % + 100 mΩ 0.013 % + 1Ω 0.013 % + 10Ω 0.05 % + 100Ω 0.96 % + 10 kΩ Keysight 34461A
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.25) 11/03/2025 Page 4 of 12 Parameter/Equipment Range CMC2, 7,9 (±) Comments Resistance – Generate3 (0 to 11) Ω (11 to 33) Ω (33 to 110) Ω 110 Ω to 1.1 kΩ (1.1 to 11) kΩ (11 to 110) kΩ 110 kΩ to 1.1 MΩ (1.1 to 3.3) MΩ (3.3 to 11) MΩ (11 to 33) MΩ (33 to 110) MΩ (110 to 330) MΩ (330 to 1100) MΩ 49 μΩ/Ω + 0.001 Ω 51 μΩ/Ω + 0.0015 Ω 34 μΩ/Ω + 0.0014 Ω 34 μΩ/Ω + 0.002 Ω 34 μΩ/Ω + 0.02 Ω 34 μΩ/Ω + 0.2 Ω 39 μΩ/Ω + 2 Ω 73 μΩ/Ω + 30 Ω 0.014 % + 50 Ω 0.03 % + 2.5 kΩ 0.06 % + 3 kΩ 0.36 % + 100 kΩ 1.8 % + 500 kΩ Fluke 5522A Parameter/Equipment Range CMC2, 7,9 (±) Comments Capacitance – Generate3 (220 to 399.9) pF (0.4 to 1.0999) nF (1.1 to 3.2999) nF (3.3 to 10.9999) nF (11 to 109.999) nF (110 to 329.999) nF (0.33 to 1.099 99) µF (1.1 to 3.29999) µF (3.3 to 10.9999) µF (11 to 32.9999) µF (33 to 109.999) µF (110 to 329.999) µF (0.33 to 1.099 99) mF (1.1 to 3.299 99) mF (3.3 to 10.9999) mF (11 to 32.9999) mF (33 to 110) mF (10 to 10 000) Hz (10 to 10 000) Hz (10 to 3000) Hz (10 to 1000) Hz (10 to 1000) Hz (10 to 1000) Hz (10 to 600) Hz (10 to 300) Hz (10 to 150) Hz (10 to 120) Hz (10 to 80) Hz (0 to 50) Hz (0 to 20) Hz (0 to 6) Hz (0 to 2) Hz (0 to 0.6) Hz (0 to 0.2) Hz 0.88 % + 10 pF 0.6 % + 0.01 nF 0.6 % + 0.01 nF 0.31 % + 0.1 nF 0.31 % + 0.1 nF 0.31 % + 0.3 nF 0.31 % + 1 nF 0.31 % + 3 nF 0.31 % + 10 nF 0.49 % + 30 nF 0.55 % + 100 nF 0.55 % + 300 nF 0.55 % + 1 µF 0.55 % + 3 µF 0.56 % + 10 µF 0.91 % + 30 µF 1.4 % + 100 µF Fluke 5522A AC Voltage – Measure3 (0 to 10) mV (10 to 100) mV 10 Hz to 20) kHz (20 to 50) kHz (50 to 100) kHz 10 Hz to 20) kHz (20 to 50) kHz (50 to 100) kHz 0.034 % + 1.1 µV 0.041 % + 1.1 µV 0.042 % + 1.1 µV 0.01 % + 0.5 µV 0.014 % + 0.4 µV 0.024 % + 1 µV Keysight 34461A
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.25) 11/03/2025 Page 5 of 12 Parameter/Range Frequency CMC2, 7,9 (±) Comments AC Voltage – Measure3 (cont) (0.1 to 1) V (1 to 10) V (10 to 100) V (100 to 750) V (1 to 6) kV 10 Hz to 20) kHz (20 to 50) kHz (50 to 100) kHz 10 Hz to 20) kHz (20 to 50) kHz (50 to 100) kHz 10 Hz to 20) kHz (20 to 50) kHz (50 to 100) kHz 10 Hz to 20) kHz (20 to 50) kHz (50 to 100) kHz (50 to 60) Hz 0.008 % + 5 µV 0.013 % + 5 µV 1.1 % + 1 mV 0.22 % + 3 mV 1.1 % + 10 mV 0.016 % + 0.5mV 0.017 % + 0.5mV 0.027 % + 1 mV 0.061 % + 5 mV 0.38 % + 50 mV 1.2 % + 0.5 V 0.15 % + 0.6 V 1.6 % Keysight 34461A Fluke 80K-6 w/DMM AC Voltage – Generate3 (1 to 33) mV (33 to 330) mV 330 mV to 3.3 V (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz 0.11 % + 6 µV 0.024 % + 6 µV 0.029 % + 6 µV 0.13 % + 6 µV 0.43 % + 12 µV 0.97 % + 50 µV 0.04 % + 8 µV 0.018 % + 8 µV 0.02 % + 8 µV 0.043 % + 8 µV 0.097 % + 32 µV 0.25 % + 70 µV 0.04 % + 50 µV 0.019 % + 60 µV 0.023 % + 60 µV 0.036 % + 50 µV 0.085 % + 130 µV 0.29 % + 600 µV Fluke 5522A
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.25) 11/03/2025 Page 6 of 12 Parameter/Range Frequency CMC2, 7,9 (±) Comments AC Voltage – Generate3 (cont) (3.3 to 33) V (33 to 330) V (330 to 1020) V (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 10 kHz 0.04 % + 650 µV 0.019 % + 600 µV 0.029 % + 600 µV 0.043 % + 600 µV 0.11 % + 1.6 mV 0.024 % + 2 mV 0.025 % + 6 mV 0.03 % + 6 mV 0.038 % + 6 mV 0.25 % + 50 mV 0.037 % + 10 mV Fluke 5522A AC Current – Measure3 (0 to 0.1) mA (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A (1 to 3.0) A (3.0 to 10) A 3 Hz to 5 kHz (5 to 10) kHz 3 Hz to 5 kHz (5 to 10) kHz 3 Hz to 5 kHz (5 to 10) kHz 3 Hz to 5 kHz (5 to 10) kHz 3 Hz to 5 kHz (5 to 10) kHz 3 Hz to 5 kHz (5 to 10) kHz 3 Hz to 5 kHz (5 to 10) kHz 0.19 % + 0.04 µA 0.24 % + 0.04 µA 0.13 % + 0.4 µA 0.13 % + 0.4 µA 0.13 % + 4 µA 0.13 % + 4 µA 0.2 % + 40 µA 0.21 % + 40 µA 0.14 % + 0.4 mA 0.14 % + 0.4 mA 0.29 % + 1.2 mA 0.33 % + 1.2 mA 0.19 % + 4 mA 0.19 % + 4 mA Keysight 34461A
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.25) 11/03/2025 Page 7 of 12 Parameter/Range Frequency CMC2, 7,9 (±) Comments AC Current – Generate3 (0 to 0.33) mA (0.33 to 3.3) mA (3.3 to 33) mA (33 to 330) mA (0.33 to 1.1) A (1.1 to 3.0) A (3.0 to 11) A (11 to 20.5) A (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 45 Hz to 1 kHz (1 to 5) kHz 45 Hz to 1 kHz (1 to 5) kHz 0.25 % + 0.1 µA 0.18 % + 0.1 µA 0.16 % + 0.1 µA 0.37 % + 0.15 µA 0.97 % + 0.2 µA 1.9 % + 0.4 µA 0.24 % + 0.15 µA 0.15 % + 0.15 µA 0.13 % + 0.15 µA 0.25 % + 0.2 µA 0.6 % + 0.3 µA 1.2 % + 0.6 µA 0.22 % + 2 µA 0.11 % + 2 µA 0.05 % + 2 µA 0.1 % + 2 µA 0.25 % + 3 µA 0.49 % + 4 µA 0.22 % + 20 µA 0.11 % + 20 µA 0.05 % + 20 µA 0.13 % + 50 µA 0.25 % + 100 µA 0.49 % + 200 µA 0.22 % + 100 µA 0.063 % + 100 µA 0.73 % + 1 mA 3 % + 5 mA 0.22 % + 100 µA 0.08 % + 100 µA 0.73 % + 1 mA 3 % + 5 mA 0.13 % + 2 mA 3.6 % + 2 mA 0.19 % + 5 mA 3.6 % + 5 mA Fluke 5522A
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.25) 11/03/2025 Page 8 of 12 Parameter/Equipment Range CMC2 (±) Comments Electrical Simulation and Measure of Thermocouples, Temperature Displays and Readouts3 – Type E Type J Type K Type N Type R Type S Type T Type U (-250 to -200) °C (-200 to -100) °C (-100 to 700) °C (700 to 1000) °C (-210 to -100) °C (-100 to 700) °C (700 to 1200) °C (-250 to -200) °C (-200 to -100) °C (-100 to 600) °C (600 to 1372) °C (-250 to -200) °C (-200 to -100) °C (-100 to 1300) °C (-50 to 0) °C (0 to 200) °C (200 to 1768) °C (-50 to 0) °C (0 to 200) °C (200 to 1768) °C (-250 to -100) °C (-100 to 0) °C (0 to 400) °C (-200 to 0) °C (0 to 600) °C 0.49 °C 0.22 °C 0.19 °C 0.21 °C 0.27 °C 0.32 °C 0.26 °C 0.88 °C 0.32 °C 0.22 °C 0.31 °C 1.4 °C 0.42 °C 0.27 °C 1.0 °C 0.7 °C 0.48 °C 0.93 °C 0.69 °C 0.55 °C 0.68 °C 0.19 °C 0.18 °C 0.29 °C 0.16 °C Additel 227A Electrical Simulation and Measure of RTDs, Displays and Readouts3 Pt100 385, Pt100 392, Pt100 3916 and Pt100 3926 (-200 to 200) °C (200 to 600) °C (600 to 850) °C 0.098 °C 0.14 °C 0.17 °C Additel 227A
9--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.25) 11/03/2025 Page 9 of 12 V. Mechanical Parameter/Equipment Range CMC2, 4, 6,9 (±) Comments Torque Wrenches3 4 lbf∙in to 600 lbf∙ft 0.78 % CDI 1001-O-DTT CDI suretest 5000-ST Torque Testers Up to 250 lbf·ft 0.08 % Class F weights w/ torque arms Force3 Measuring Equipment – Tension & Compression Up to 100 lbf 0.05 % + 0.6R Class F weights Scale & Balances3 Truck & Rail Scales8 1 mg to 1 g (1 to 5) g Up to 10 g Up to 30 g Up to 50 g Up to 100 g Up to 200 g Up to 300 g Up to 500 g Up to 1000 g (> 1 to 6) kg (1 to 20 000) g (> 20 to 5000) kg Up to 20 000 lbs Up to 200 000 lbs 0.013 mg + 0.6R 0.043 mg + 0.6R 0.062 mg + 0.6R 0.096 mg + 0.6R 0.17 mg + 0.6R 0.31 mg + 0.6R 0.63 mg + 0.6R 0.92 mg + 0.6R 1.5 mg + 0.6R 3.1 mg + 0.6R 3.1 mg per 1000 g + 0.6R 0.017 % + 0.6R 0.017 % + 0.6R 0.017 % + 0.6R 0.017 % + 0.6R ASTM Class 1 weights (applied load) Class F weights (applied load) Vacuum – Measuring Equipment 3 Down to 28.5 in∙Hg 0.056 in∙Hg Additel ADT681A Speed/RPM/Rate Simulation3 (6 to 200 000) rpm 0.0017 % Agilent 33250A
4 to 600 lbf∙ft
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.25) 11/03/2025 Page 10 of 12 Parameter/Equipment Range CMC2,6,9 (±) Comments Pressure3 – Measuring Equipment & Measure Pneumatic Hydraulic Up to 30 psig Up to 300 psig (300 to 1000) psig (1000 to 10 000) psig 0.03 psig 0.2 psig 0.61 psig 6.2 psig Additel ADT 681A Additel ADT 681A Additel ADT 681A Additel ADT681A Speed3 – Measure Optic/Non-Contact: RPM Totalizer/Rate Meters Contact: RPM Totalizer/Rate Meters (6 to 200 000) rpm (2 to 3300) fpm (6 to 20 000) rpm (2 to 3300) fpm 0.018 % 0.018 % 0.22 % 0.22 % Monarch PLT200 Totalize Meters3 – (Length Counters & Totalizers) Distance Measure Up to 2000 yards 0.7 % Monarch PLT200 w/ encoder wheel VI. Thermodynamics Parameter/Equipment Range CMC2, 6 (±) Comments Temperature – Measure3 (-80 to 140) °C (140 to 670) °C 0.046 °C 0.068 °C Isotech TTI-10 w/PRT probe Temperature – Measuring Equipment3 (-25 to 145) °C (35 to 660) °C 0.14 °C 0.18 °C Isotech 4936 w/ reference probe Isotech 4852 w/reference probe
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.25) 11/03/2025 Page 11 of 12 Parameter/Equipment Range CMC2, 6,9 (±) Comments Infrared Temperature – Measuring Devices3 35 °C (35 to 100) °C (100 to 200) °C (200 to 350) °C (350 to 500) °C 0.63 °C 0.77 °C 1.0 °C 1.6 °C 2.2 °C Fluke 4181, Emissivity ε = 0.95 where wavelength λ = (8 to 14) µm Relative Humidity – Measure3 (10 to 90) % RH 1.0 % RH Rotronic HC2-SH Relative Humidity – Measuring Equipment3 (20 to 80) % RH 1.0 % RH Rotronic HC2-SH w/ controlled environment VII. Time & Frequency Parameter/Equipment Range CMC2, 6 (±) Comments Frequency – Measuring Equipment3 0.01 Hz to 2 MHz Up to 80 MHz 5.6 µHz/Hz + 5 μHz 0.06 µHz/Hz Fluke 5522A Keysight 53250A Frequency – Measure3 Up to 350 MHz 0.06 µHz/Hz Keysight 53230A Timers & Stopwatches3 (1 to 3600) s 0.032 s Keysight 53230A ______________________________________________________________ 1 This laboratory offers commercial calibration and field calibration services, where noted. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration.
12--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.25) 11/03/2025 Page 12 of 12 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches, and R is the resolution of the unit under test. 5 This scope meets A2LA’s P112 Flexible Scope Policy. 6 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 7 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 8 Maximum calibration capacity of the instrument. Calibration range limited to 120 000 lb in test weight. 9 In the statement of CMC, percentages are percentage of reading, unless otherwise indicated.
to 120000 lb
13ISO/IEC 17025:2017; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

171 Vista Centre Drive, Forest, VA, 24551, US

37.36664, -79.27426

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.