Nexteer Calibration
3900 Holland Rd, 48601, Saginaw, MI, United States
Visit website- Scope lines
- 13
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 13 scope lines.
A2LA certificate 6616.01 · 13 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6616.01) 02/20/2025 Page 1 of 12
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
NEXTEER CALIBRATION LAB
3900 Holland Road
Saginaw, MI 48601
Tony Powell Phone: 989 233 8019
CALIBRATION
Valid To: August 31, 2026 Certificate Number: 6616.01
In recognition of the successful co mpletion of the A2LA evaluation process (including an assessment of
the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is
granted to this laboratory to perform the following calibrations
1, 6:
I. Acoustical
Parameter/Equipment
Range CMC
2 (±) Comments
Microphone Sensitivity
250 Hz & 1 kHz
(-80 to 0) dB
0.96 dB re 1 V/Pa
PCB 9350C (11185)
II. Dimensional
Parameter/Equipment
Range CMC
2, 4, 5 (±) Comments
Calipers, Micrometers,
Indicators
Length Only
Up to 90 mm
Up to 20 in
9.9 µm
320 in
Hultgren 229 (12354)
SAE gage blocks
(12251)
String Pots
Up to 350 mm
0.32 mm
Measurement
Specialties – PT1E
(16351) | -80 to 0 dB |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6616.01) 02/20/2025 Page 2 of 12
Parameter/Equipment
Range CMC 2, 4, 5 (±) Comments
LVDT’s
Up to 350 mm
0.32 mm
Measurement
Specialties – PT1E
(16351)
Angle ‒ Measuring
Equipment
(0 to 180)°
27 arc mins
Starrett angle block
(11451)
Angle ‒ Measure
(Up to 360)°
56 arc secs
Gurley DIRA23AN
(21280)
III. Electrical– DC/Low Frequency
Parameter/Equipment
Range CMC
2, 7 (±) Comments
DC Voltage ‒ Measure
(0 to 100) mV
(0.1 to 1) V
(1 to 10) V
(10 to 100) V
(100 to 1000) V
24 µV
58 µV
400 µV
5.7 mV
63 mV
Fluke 8846A (12621)
DC Voltage ‒ Generate
(0 to 330) mV
(0.33 to 3.3) V
(3.3 to 33) V
(33 to 330) V
(330 to 1000) V
6.0 µV/V + 22 µV
13 µV/V + 32 µV
16 µV/V + 17 µV
23 µV/V + 120 µV
0.021 mV/V + 2.0 mV
Fluke 5522A (12347)
DC Current ‒ Measure
(0 to 100) µA
(0.10 to 1.0) mA
(1.0 to 10) mA
(10 to 100) mA
(0.10 to 1.0) A
(1 to 3.0) A
(3.0 to 10) A
580 µA/A + 0.039 µA
600 µA/A + 0.063 µA
600 µA/A + 2.3 µA
600 µA/A + 6.2 µA
1.0 mA/A + 0.13 mA
1.3 mA/A + 0.66 mA
2.5 mA/A – 0.58 mA
Fluke 8846A (12621) | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6616.01) 02/20/2025 Page 3 of 12
Parameter/Equipment
Range CMC 2, 7 (±) Comments
DC Current ‒ Generate
(0 to 330) µA
(0.33 to 3.3) mA
(3.3 to 33) mA
(33 to 330) mA
(0.33 to 3) A
(3 to 20) A
170 µA/A + 0.027 µA
120 µA/A + 0.066 µA
290 µA/A - 0.91 µA
370 µA/A - 15 µA
710 µA/A + 72 µA
1.1 mA/A + 3.6 mA
Fluke 5522A (12347)
Resistance ‒ Measure
(0.002 to 2) mΩ
Up to 10Ω
(10 to 100) Ω
(100 to 1,000) Ω
(1 to 100) KΩ
(100 to 1,100) KΩ
(1.1 to 1,000) MΩ
0.36 µΩ
5.0 mΩ
0.14 mΩ/Ω + 3.6 mΩ
0.13 mΩ/Ω + 4.3 mΩ
0.13 mΩ/Ω – 0.058 mΩ
0.13 mΩ/Ω – 190 mΩ
2.3 % - 25 KΩ
Valhalla 4300B (4286)
Fluke 8846A (12621)
Resistance ‒ Generate
Up to 10.9999 Ω
(11 to 32.9999) Ω
(33 to 109.9999) Ω
(110 to 329.9999) Ω
(330 to 1099.999) Ω
(1.1 to 3.299 999) KΩ
(3.3 to 10.999 99) KΩ
(11 to 32.999 99) KΩ
(33 to 109.9999) KΩ
(110 to 329.999 99) KΩ
(330 to 1,099.999) KΩ
(1.1 to 3.299 999) MΩ
(3.3 to 10.999 99) MΩ
(11 to 32.999 99) MΩ
(33 to 109.9999) MΩ
(110 to 329.9999) MΩ
(330 to 1100) MΩ
50 mΩ
56 mΩ
55 mΩ
55 mΩ
66 mΩ
0.18 Ω
0.40 Ω
1.6 Ω
3.9 Ω
15 Ω
44 Ω
0.57 KΩ
1.8 KΩ
25 KΩ
69 KΩ
7.6 MΩ
25 MΩ
Fluke 5522A (12347) | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6616.01) 02/20/2025 Page 4 of 12
Parameter/Range
Frequency CMC 2, 7 (±) Comments
AC Voltage – Measure
(1 to 100) mV
(0.10 to 1.0) V
(1.0 to 10) V
(10 to 100) V
(100 to 1000) V
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 300) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 300) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
45 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
45 Hz to 1 kHz
(1 to 20) kHz
4.6 mV/V + 0.040 mV
0.82 mV/V + 0.046 mV
1.1 mV/V + 0.039 mV
2.2 mV/V + 0.046 mV
53 mV/V + 0.44 mV
4.6 mV/V + 0.040 mV
0.82 mV/V + 0.046 mV
1.1 mV/V + 0.039 mV
2.2 mV/V + 0.046 mV
53 mV/V + 0.44 mV
4.6 mV/V + 0.040 mV
0.82 mV/V + 0.046 mV
1.1 mV/V + 0.039 mV
2.2 mV/V + 0.046 mV
0.82 mV/V + 0.046 mV
1.1 mV/V + 0.039 mV
2.2 mV/V + 0.046 mV
0.82 mV/V + 0.046 mV
1.1 mV/V + 0.039 mV
Fluke 8846A
(12621)
AC Voltage – Generate
(1 to 33) mV
(33 to 330) mV
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 200) kHz
(200 to 300) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 200) kHz
(200 to 300) kHz
1.1 mV/V + 0.022 mV
0.27 mV/V + 0.013 mV
90 µV/V + 18 µV
1.1 mV/V + 0.011 mV
9.1 mV/V + 0.061 mV
9.2 mV/V + 0.060 mV
1.9 mV/V – 0.0027 mV
830 µV/V – 0.22 µV
840 µV/V + 1.0 µV
710 µV/V + 5.4 µV
2.4 mV/V + 0.080 mV
2.4 mV/V + 0.10 mV
Fluke 5522A
(12347) | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6616.01) 02/20/2025 Page 5 of 12
Parameter/Range
Frequency CMC 2, 7 (±) Comments
AC Voltage – Generate
(cont)
(0.33 to 3.3) V
(3.3 to 33) V
(33 to 330) V
(330 to 1000) V
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 200) kHz
(200 to 300) kHz
10 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 20) kHz
2.3 mV/V + 0.58 mV
0.16 mV/V + 0.11 mV
590 µV/V + 80 µV
590 µV/V – 110 µV
0.83 mV/V + 0.58 mV
2.8 mV/V + 0.84 mV
0.17 mV/V + 1.2 mV
0.21 mV/V + 1.1 mV
420 µV/V + 850 µV
1.0 mV/V + 2.3 mV
0.23 mV/V + 8.6 mV
0.27 mV/V + 5.9 mV
0.34 mV/V + 18 mV
2.3 mV/V + 58 mV
0.35 mV/V + 11 mV
0.34 mV/V + 19 mV
Fluke 5522A
(12347)
AC Current ‒ Measure
(5 to 100) µA
100 µA to 1 mA
(1 to 10) mA
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
3.6 mA/A + 0.000 089 mA
3.6 mA/A + 0.000 032 mA
3.9 mA/A + 0.000 013 mA
38 mA/A – 0.0016 mA
35 mA/A – 0.0013 mA
18 mA/A + 0.000 87 mA
3.6 mA/A + 0.000 089 mA
3.6 mA/A + 0.000 032 mA
3.9 mA/A + 0.000 013 mA
38 mA/A – 0.0016 mA
35 mA/A – 0.0013 mA
18 mA/A + 0.000 87 mA
3.6 mA/A + 0.000 089 mA
34 mA/A + 0.000 032 mA
3.9 mA/A + 0.000 013 mA
38 mA/A – 0.0016 mA
35 mA/A – 0.0013 mA
18 mA/A + 0.000 87 mA
Fluke 8846A (12621) | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6616.01) 02/20/2025 Page 6 of 12
Parameter/Range
Frequency CMC 2, 7 (±) Comments
AC Current ‒ Measure
(cont)
(10 to 100) mA
(100 to 400) mA
400 mA to 3 A
(3 to 10) A
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
3.6 mA/A + 0.000 089 mA
3.6 mA/A + 0.000 032 mA
3.9 mA/A + 0.000 013 mA
38 mA/A – 0.0016 mA
35 mA/A – 0.0013 mA
18 mA/A + 0.000 87 mA
3.6 mA/A + 0.000 089 mA
3.6 mA/A + 0.000 032 mA
3.9 mA/A + 0.000 013 mA
38 mA/A – 0.0016 mA
35 mA/A – 0.0013 mA
18 mA/A + 0.000 87 mA
3.6 mA/A + 0.000 089 mA
3.6 mA/A + 0.000 032 mA
3.9 mA/A + 0.000 013 mA
38 mA/A – 0.0016 mA
35 mA/A – 0.0013 mA
3.6 mA/A + 0.000 032 mA
3.9 mA/A + 0.000 013 mA
38 mA/A – 0.0016 mA
Fluke 8846A (12621)
AC Current – Generate
(29 to 330) µA
330 µA to 3.3 mA
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
2.8 mA/A + 0.000 087 mA
2.0 mA/A + 0.000 087 mA
2.2 mA/A + 0.000 071 mA
9.3 mA/A + 0.000 23 mA
9.3 mA/A + 0.000 23 mA
19 mA/A + 0.000 46 mA
2.9 mA/A – 0.000 15 mA
5.5 mA/A – 0.0028 mA
2.7 mA/A + 0.000 071 mA
6.1 mA/A + 0.000 16 mA
6.0 mA/A + 0.000 24 mA
12 mA/A + 0.000 71 mA
Fluke 5522A (12347) | ||
| 7 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6616.01) 02/20/2025 Page 7 of 12
Parameter/Range
Frequency CMC 2, 7 (±) Comments
AC Current – Generate
(cont)
(3.3 to 33) mA
(33 to 330) mA
330 mA to 3 A
(3 to 11) A
(11 to 20) A
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
2.9 mA/A – 0.0025 mA
1.7 mA/A + 0.012 mA
1.5 mA/A – 0.0017 mA
1.7 mA/A – 0.0012 mA
4.8 mA/A + 0.0037 mA
4.9 mA/A + 0.0059 mA
2.1 mA/A + 0.034 mA
780 µA/A + 88 µA
4.6 mA/A + 0.034 mA
1.1 mA/A + 0.084 mA
2.3 mA/A + 0.13 mA
7.9 mA/A – 0.033 mA
2.3 mA/A + 0.33 mA
2.2 mA/A + 0.22 mA
7.0 mA/A + 1.2 mA
7.0 mA/A + 1.2 mA
29 mA/A + 6.0 mA
1.8 mA/A + 6.0 mA
1.5 mA/A + 11 mA
35 mA/A + 6.2 mA
1.6 mA/A + 8.2 mA
2.7 mA/A + 1.4 mA
36 mA/A – 0.87 mA
Fluke 5522A (12347)
Parameter/Equipment
Range CMC 2, 7 (±) Comments
Capacitance ‒– Generate
(220 to 400) pF
(0.4 to 1.1) nF
(1.1 to 3.3) nF
(3.3 to 11) nF
(11 to 33) nF
(33 to 110) nF
(110 to 330) nF
(0.33 to 1.1) µF
0.026 pF/pF + 7.1 pF
0.0026 pF/pF + 14 pF
0.0058 pF/pF + 12 pF
0.0043 pF/pF + 18 pF
0.0085 pF/pF – 16 pF
0.0030 pF/pF + 150 pF
0.0045 pF/pF + 28 pF
0.0041 pF/pF + 620 pF
Fluke 5522A (12347) | to 30 kHz |
| 8 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6616.01) 02/20/2025 Page 8 of 12
Parameter/Equipment
Range CMC 2, 7 (±) Comments
Capacitance ‒– Generate
(cont)
(1.1 to 3.3) µF
(3.3 to 11) µF
(11 to 33) µF
(33 to 110) µF
(110 to 330) µF
(0.33 to 1.1) mF
(1.1 to 3.3) mF
(3.3 to 11) mF
(11 to 33) mF
(33 to 110) mF
0.0045 pF/pF + 280 pF
0.0041 nF/nF + 6.2 nF
0.0070 nF/nF - 17 nF
0.0066 nF/nF + 31 nF
0.0065 nF/nF + 37 nF
0.0062 µF/µF + 0.48 µF
0.0066 µF/µF + 0.17 µF
0.0063 µF/µF + 4.7 µF
0.012 µF/µF – 39 µF
0.016 mF/mF – 0.11 mF
Fluke 5522A (12347)
Electrical Calibration of
RTD Indicators &
Indicating Systems –
Pt 385, 100Ω
(-200 to 800) °C
0.38 °C
General Radio 1434-G
(1370)
Electrical Calibration of
Thermocouple Indicators &
Indicating Systems –
Type J
Type K
Type T
(-200 to 1200) °C
(-200 to 1200) °C
(-200 to 400) °C
0.38 °C
0.48 °C
0.51 °C
Fluke 5522A (12347)
Electrical Calibration of
Thermocouple Simulators
& Simulating Systems –
Type J
Type K
Type T
(-200 to 1200) °C
(-200 to 1200) °C
(-200 to 400) °C
0.32 °C
0.40 °C
0.43 °C
Fluke 5522A (12347) | -200 to 1200 °C |
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6616.01) 02/20/2025 Page 9 of 12
IV. Fluid Quantities
Parameter/Equipment
Range CMC 2, 3 (±) Comments
Flow Meters
Up to 10 GPM
0.083 %
Max Machinery
(9818-9)
V. Mechanical
Parameter/Equipment
Range CMC
2, 3 (±) Comments
Accelerometer Sensitivity
5 Hz to 3 kHz
(3 to 6) kHz
(6 to 9) kHz
(9 to 12) kHz
(12 to 15) kHz
0.94 %
1.7 %
2.5 %
3.2 %
4.0 %
PCB K9155D11
(10834)
Torque Wrenches
(0.452 to 5.65) Nm
(3.39 to 45.2) Nm
(9.04 to 113) Nm
(27.12 to 339) Nm
(81.36 to 813.6) Nm
(271.2 to 2712) Nm
1.8 %
0.55 %
0.42 %
0.37 %
0.36 %
0.35 %
Snap-On TTC 2000
SYS (12739)
Torque Transducer
(0.3125 to 5) lbfꞏin
(5 to 520) lbfꞏin
(20 to 2000) lbfꞏin
(1180 to 8850) lbfꞏin
(1770 to 10 000) lbfꞏin
0.23 % F.S.
0.23 %
0.11 %
0.15 %
0.25 %
0"/20" beam (3943) w/
Troemner S22E-C
(12683)
0"/20" beam (3943) w/
Troemner S22E-C
(12683)
20" beam (3943) w/
Rice Lake weights
(13087)
59" beam (4438) w/
Rice Lake weights
(13087)
Lebow 2111-10K
(18655) | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6616.01) 02/20/2025 Page 10 of 12
Parameter/Equipment
Range CMC 2, 3, 5 (±) Comments
Torque Transducer (cont)
(2 to 20) klbfꞏin
(5 to 50) klbfꞏin
(10 to 100) klbfꞏin
(20 to 200) klbfꞏin
0.42 % + 16 lbfꞏin
0.045 % + 97 lbfꞏin
0.090 % + 170 lbfꞏin
0.0059 % + 370 lbfꞏin
Interface 5411-20K
(18497)
Lebow 2112-50K
(18653)
Lebow 2112-100K
(18652)
Lebow 2113-200K
(18718)
Force ‒
Compression/Tension –
Measure & Measuring
Equipment
(1 to 2000) gf
(0.125 to 20) lbf
(1 to 150) lbf
(30 to 1000) lbf
(250 to 5000) lbf
(1000 to 10 000) lbf
(2000 to 25 000) lbf
(60 to 300) klbf
0.023 % + 1.1 gf
0.015 % + 0.0011 lbf
0.091 %
0.73 %
0.57 %
0.96 %
0.96 %
0.032 % + 390 lbf
Troemner 507B
(1024)
Troemner S22E-C
(12683)
Rice Lake weights
(13087)
Lebow 3169-108
(18724)
Interface 1610AJH-5K
(18496)
BLH Electronics C3P1
(17149)
Interface 1620AJH-25K
(19841)
Load Cell Central –
PSCG-300K (18546)
Pressure ‒ Measuring
Equipment
(0.2 to 100) psig
(100 to 3000) psig
(500 to 5000) psig
0.070 % FS
0.35 %
0.064 %
Eaton UPC 5100 BA
(427)
Amthor 460
(248)
Budenburg 480M
(4466)
Pressure ‒ Measure
(0.2 to 100) psig
0.069 % FS
Eaton UPC 5100 BA
(427)
Scales
Up to 2000 g
Up to 27 lbs
(1 to 150) lbs
(50 to 500) lbs
0.078 % FS
0.87 %
0.091 %
0.12 %
Troemner 507B (1024)
Troemner S22E-C
(12683)
Rice Lake weights
(13087)
Rice Lake weights –
50 Lb set (2891) | ||
| 11 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6616.01) 02/20/2025 Page 11 of 12
Parameter/Equipment
Range
CMC2 (±)
Comments
Non-Contact
Tachometers
(10 to 100 000) RPM
0.11 RPM
Keysight 33612A,
LED (12985)
Contact Tachometers
(1 to 7000) RPM
1.6 RPM
Hewlett Packard
5512-A (497)
VI. Thermodynamics
Parameter/Equipment
Range CMC
2, 5 (±) Comments
Temperature – Measure
(-40 to 120) °C
1.1 °C
Vaisala HMT330
(9874)
Humidity – Measure
(15 to 95) % RH
4.0 % RH
Vaisala HMT330
(9874)
Infrared Thermometers
(35 to 215) °C
2.2 °C
Omega BB702 (9358)
VII. Time & Frequency
Parameter/Equipment
Range CMC
2, 5 (±) Comments
Frequency ‒ Generate
1 kHz to 20 MHz
2.7 µHz/Hz + 1.6 µHz
Keysight 33612A
(12985)
Frequency ‒ Measure
5 Hz to 20 MHz
8.5 µHz/Hz + 1600 µHz
Fluke 1900A (4642)
________________________________
1 This laboratory does not offer commercial calibration service. | 10 to 100000 RPM |
| 12 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6616.01) 02/20/2025 Page 12 of 12
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 In the statement of CMC, percentages are percentage of reading, unless otherwise indicated.
4 L is the numerical value of the nominal length of the device measured in inches or in meters,
corresponding to the system of units used in the uncertainty.
5 The type of instrument or material being calib rated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
6 This scope meets A2LA’s P112 Flexible Scope Policy.
7 The stated measured values are determined usi ng the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a
fraction/percentage of the reading plus a fixed floor specification. | ||
| 13 | Extracted from the scope document; tables may not line up. View scope for the original. For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
NEXTEER CALIBRATION LAB
Saginaw, MI
for technical competence in the field of
Calibration
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This laboratory also meets R205 – Specific
Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a
defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 20th day of February 2025.
__ _____________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 6616.01
Valid to August 31, 2026 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.