Registers refreshed 2026-11-20.See refresh dates
United States

Nexteer Calibration

3900 Holland Rd, 48601, Saginaw, MI, United States

Visit website
A2LA 6616.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
13
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 13 scope lines.

A2LA certificate 6616.01 · 13 lines

LineMethodMatrixRange
1--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6616.01) 02/20/2025 Page 1 of 12 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 NEXTEER CALIBRATION LAB 3900 Holland Road Saginaw, MI 48601 Tony Powell Phone: 989 233 8019 CALIBRATION Valid To: August 31, 2026 Certificate Number: 6616.01 In recognition of the successful co mpletion of the A2LA evaluation process (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 6: I. Acoustical Parameter/Equipment Range CMC 2 (±) Comments Microphone Sensitivity 250 Hz & 1 kHz (-80 to 0) dB 0.96 dB re 1 V/Pa PCB 9350C (11185) II. Dimensional Parameter/Equipment Range CMC 2, 4, 5 (±) Comments Calipers, Micrometers, Indicators Length Only Up to 90 mm Up to 20 in 9.9 µm 320 in Hultgren 229 (12354) SAE gage blocks (12251) String Pots Up to 350 mm 0.32 mm Measurement Specialties – PT1E (16351)
-80 to 0 dB
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6616.01) 02/20/2025 Page 2 of 12 Parameter/Equipment Range CMC 2, 4, 5 (±) Comments LVDT’s Up to 350 mm 0.32 mm Measurement Specialties – PT1E (16351) Angle ‒ Measuring Equipment (0 to 180)° 27 arc mins Starrett angle block (11451) Angle ‒ Measure (Up to 360)° 56 arc secs Gurley DIRA23AN (21280) III. Electrical– DC/Low Frequency Parameter/Equipment Range CMC 2, 7 (±) Comments DC Voltage ‒ Measure (0 to 100) mV (0.1 to 1) V (1 to 10) V (10 to 100) V (100 to 1000) V 24 µV 58 µV 400 µV 5.7 mV 63 mV Fluke 8846A (12621) DC Voltage ‒ Generate (0 to 330) mV (0.33 to 3.3) V (3.3 to 33) V (33 to 330) V (330 to 1000) V 6.0 µV/V + 22 µV 13 µV/V + 32 µV 16 µV/V + 17 µV 23 µV/V + 120 µV 0.021 mV/V + 2.0 mV Fluke 5522A (12347) DC Current ‒ Measure (0 to 100) µA (0.10 to 1.0) mA (1.0 to 10) mA (10 to 100) mA (0.10 to 1.0) A (1 to 3.0) A (3.0 to 10) A 580 µA/A + 0.039 µA 600 µA/A + 0.063 µA 600 µA/A + 2.3 µA 600 µA/A + 6.2 µA 1.0 mA/A + 0.13 mA 1.3 mA/A + 0.66 mA 2.5 mA/A – 0.58 mA Fluke 8846A (12621)
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6616.01) 02/20/2025 Page 3 of 12 Parameter/Equipment Range CMC 2, 7 (±) Comments DC Current ‒ Generate (0 to 330) µA (0.33 to 3.3) mA (3.3 to 33) mA (33 to 330) mA (0.33 to 3) A (3 to 20) A 170 µA/A + 0.027 µA 120 µA/A + 0.066 µA 290 µA/A - 0.91 µA 370 µA/A - 15 µA 710 µA/A + 72 µA 1.1 mA/A + 3.6 mA Fluke 5522A (12347) Resistance ‒ Measure (0.002 to 2) mΩ Up to 10Ω (10 to 100) Ω (100 to 1,000) Ω (1 to 100) KΩ (100 to 1,100) KΩ (1.1 to 1,000) MΩ 0.36 µΩ 5.0 mΩ 0.14 mΩ/Ω + 3.6 mΩ 0.13 mΩ/Ω + 4.3 mΩ 0.13 mΩ/Ω – 0.058 mΩ 0.13 mΩ/Ω – 190 mΩ 2.3 % - 25 KΩ Valhalla 4300B (4286) Fluke 8846A (12621) Resistance ‒ Generate Up to 10.9999 Ω (11 to 32.9999) Ω (33 to 109.9999) Ω (110 to 329.9999) Ω (330 to 1099.999) Ω (1.1 to 3.299 999) KΩ (3.3 to 10.999 99) KΩ (11 to 32.999 99) KΩ (33 to 109.9999) KΩ (110 to 329.999 99) KΩ (330 to 1,099.999) KΩ (1.1 to 3.299 999) MΩ (3.3 to 10.999 99) MΩ (11 to 32.999 99) MΩ (33 to 109.9999) MΩ (110 to 329.9999) MΩ (330 to 1100) MΩ 50 mΩ 56 mΩ 55 mΩ 55 mΩ 66 mΩ 0.18 Ω 0.40 Ω 1.6 Ω 3.9 Ω 15 Ω 44 Ω 0.57 KΩ 1.8 KΩ 25 KΩ 69 KΩ 7.6 MΩ 25 MΩ Fluke 5522A (12347)
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6616.01) 02/20/2025 Page 4 of 12 Parameter/Range Frequency CMC 2, 7 (±) Comments AC Voltage – Measure (1 to 100) mV (0.10 to 1.0) V (1.0 to 10) V (10 to 100) V (100 to 1000) V (10 to 45) Hz 45 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 300) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 300) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz 45 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz 45 Hz to 1 kHz (1 to 20) kHz 4.6 mV/V + 0.040 mV 0.82 mV/V + 0.046 mV 1.1 mV/V + 0.039 mV 2.2 mV/V + 0.046 mV 53 mV/V + 0.44 mV 4.6 mV/V + 0.040 mV 0.82 mV/V + 0.046 mV 1.1 mV/V + 0.039 mV 2.2 mV/V + 0.046 mV 53 mV/V + 0.44 mV 4.6 mV/V + 0.040 mV 0.82 mV/V + 0.046 mV 1.1 mV/V + 0.039 mV 2.2 mV/V + 0.046 mV 0.82 mV/V + 0.046 mV 1.1 mV/V + 0.039 mV 2.2 mV/V + 0.046 mV 0.82 mV/V + 0.046 mV 1.1 mV/V + 0.039 mV Fluke 8846A (12621) AC Voltage – Generate (1 to 33) mV (33 to 330) mV (10 to 45) Hz 45 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 200) kHz (200 to 300) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 200) kHz (200 to 300) kHz 1.1 mV/V + 0.022 mV 0.27 mV/V + 0.013 mV 90 µV/V + 18 µV 1.1 mV/V + 0.011 mV 9.1 mV/V + 0.061 mV 9.2 mV/V + 0.060 mV 1.9 mV/V – 0.0027 mV 830 µV/V – 0.22 µV 840 µV/V + 1.0 µV 710 µV/V + 5.4 µV 2.4 mV/V + 0.080 mV 2.4 mV/V + 0.10 mV Fluke 5522A (12347)
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6616.01) 02/20/2025 Page 5 of 12 Parameter/Range Frequency CMC 2, 7 (±) Comments AC Voltage – Generate (cont) (0.33 to 3.3) V (3.3 to 33) V (33 to 330) V (330 to 1000) V (10 to 45) Hz 45 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 200) kHz (200 to 300) kHz 10 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 20) kHz 2.3 mV/V + 0.58 mV 0.16 mV/V + 0.11 mV 590 µV/V + 80 µV 590 µV/V – 110 µV 0.83 mV/V + 0.58 mV 2.8 mV/V + 0.84 mV 0.17 mV/V + 1.2 mV 0.21 mV/V + 1.1 mV 420 µV/V + 850 µV 1.0 mV/V + 2.3 mV 0.23 mV/V + 8.6 mV 0.27 mV/V + 5.9 mV 0.34 mV/V + 18 mV 2.3 mV/V + 58 mV 0.35 mV/V + 11 mV 0.34 mV/V + 19 mV Fluke 5522A (12347) AC Current ‒ Measure (5 to 100) µA 100 µA to 1 mA (1 to 10) mA (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz 3.6 mA/A + 0.000 089 mA 3.6 mA/A + 0.000 032 mA 3.9 mA/A + 0.000 013 mA 38 mA/A – 0.0016 mA 35 mA/A – 0.0013 mA 18 mA/A + 0.000 87 mA 3.6 mA/A + 0.000 089 mA 3.6 mA/A + 0.000 032 mA 3.9 mA/A + 0.000 013 mA 38 mA/A – 0.0016 mA 35 mA/A – 0.0013 mA 18 mA/A + 0.000 87 mA 3.6 mA/A + 0.000 089 mA 34 mA/A + 0.000 032 mA 3.9 mA/A + 0.000 013 mA 38 mA/A – 0.0016 mA 35 mA/A – 0.0013 mA 18 mA/A + 0.000 87 mA Fluke 8846A (12621)
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6616.01) 02/20/2025 Page 6 of 12 Parameter/Range Frequency CMC 2, 7 (±) Comments AC Current ‒ Measure (cont) (10 to 100) mA (100 to 400) mA 400 mA to 3 A (3 to 10) A (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz 3.6 mA/A + 0.000 089 mA 3.6 mA/A + 0.000 032 mA 3.9 mA/A + 0.000 013 mA 38 mA/A – 0.0016 mA 35 mA/A – 0.0013 mA 18 mA/A + 0.000 87 mA 3.6 mA/A + 0.000 089 mA 3.6 mA/A + 0.000 032 mA 3.9 mA/A + 0.000 013 mA 38 mA/A – 0.0016 mA 35 mA/A – 0.0013 mA 18 mA/A + 0.000 87 mA 3.6 mA/A + 0.000 089 mA 3.6 mA/A + 0.000 032 mA 3.9 mA/A + 0.000 013 mA 38 mA/A – 0.0016 mA 35 mA/A – 0.0013 mA 3.6 mA/A + 0.000 032 mA 3.9 mA/A + 0.000 013 mA 38 mA/A – 0.0016 mA Fluke 8846A (12621) AC Current – Generate (29 to 330) µA 330 µA to 3.3 mA (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz 2.8 mA/A + 0.000 087 mA 2.0 mA/A + 0.000 087 mA 2.2 mA/A + 0.000 071 mA 9.3 mA/A + 0.000 23 mA 9.3 mA/A + 0.000 23 mA 19 mA/A + 0.000 46 mA 2.9 mA/A – 0.000 15 mA 5.5 mA/A – 0.0028 mA 2.7 mA/A + 0.000 071 mA 6.1 mA/A + 0.000 16 mA 6.0 mA/A + 0.000 24 mA 12 mA/A + 0.000 71 mA Fluke 5522A (12347)
7--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6616.01) 02/20/2025 Page 7 of 12 Parameter/Range Frequency CMC 2, 7 (±) Comments AC Current – Generate (cont) (3.3 to 33) mA (33 to 330) mA 330 mA to 3 A (3 to 11) A (11 to 20) A (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz 2.9 mA/A – 0.0025 mA 1.7 mA/A + 0.012 mA 1.5 mA/A – 0.0017 mA 1.7 mA/A – 0.0012 mA 4.8 mA/A + 0.0037 mA 4.9 mA/A + 0.0059 mA 2.1 mA/A + 0.034 mA 780 µA/A + 88 µA 4.6 mA/A + 0.034 mA 1.1 mA/A + 0.084 mA 2.3 mA/A + 0.13 mA 7.9 mA/A – 0.033 mA 2.3 mA/A + 0.33 mA 2.2 mA/A + 0.22 mA 7.0 mA/A + 1.2 mA 7.0 mA/A + 1.2 mA 29 mA/A + 6.0 mA 1.8 mA/A + 6.0 mA 1.5 mA/A + 11 mA 35 mA/A + 6.2 mA 1.6 mA/A + 8.2 mA 2.7 mA/A + 1.4 mA 36 mA/A – 0.87 mA Fluke 5522A (12347) Parameter/Equipment Range CMC 2, 7 (±) Comments Capacitance ‒– Generate (220 to 400) pF (0.4 to 1.1) nF (1.1 to 3.3) nF (3.3 to 11) nF (11 to 33) nF (33 to 110) nF (110 to 330) nF (0.33 to 1.1) µF 0.026 pF/pF + 7.1 pF 0.0026 pF/pF + 14 pF 0.0058 pF/pF + 12 pF 0.0043 pF/pF + 18 pF 0.0085 pF/pF – 16 pF 0.0030 pF/pF + 150 pF 0.0045 pF/pF + 28 pF 0.0041 pF/pF + 620 pF Fluke 5522A (12347)
to 30 kHz
8--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6616.01) 02/20/2025 Page 8 of 12 Parameter/Equipment Range CMC 2, 7 (±) Comments Capacitance ‒– Generate (cont) (1.1 to 3.3) µF (3.3 to 11) µF (11 to 33) µF (33 to 110) µF (110 to 330) µF (0.33 to 1.1) mF (1.1 to 3.3) mF (3.3 to 11) mF (11 to 33) mF (33 to 110) mF 0.0045 pF/pF + 280 pF 0.0041 nF/nF + 6.2 nF 0.0070 nF/nF - 17 nF 0.0066 nF/nF + 31 nF 0.0065 nF/nF + 37 nF 0.0062 µF/µF + 0.48 µF 0.0066 µF/µF + 0.17 µF 0.0063 µF/µF + 4.7 µF 0.012 µF/µF – 39 µF 0.016 mF/mF – 0.11 mF Fluke 5522A (12347) Electrical Calibration of RTD Indicators & Indicating Systems – Pt 385, 100Ω (-200 to 800) °C 0.38 °C General Radio 1434-G (1370) Electrical Calibration of Thermocouple Indicators & Indicating Systems – Type J Type K Type T (-200 to 1200) °C (-200 to 1200) °C (-200 to 400) °C 0.38 °C 0.48 °C 0.51 °C Fluke 5522A (12347) Electrical Calibration of Thermocouple Simulators & Simulating Systems – Type J Type K Type T (-200 to 1200) °C (-200 to 1200) °C (-200 to 400) °C 0.32 °C 0.40 °C 0.43 °C Fluke 5522A (12347)
-200 to 1200 °C
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6616.01) 02/20/2025 Page 9 of 12 IV. Fluid Quantities Parameter/Equipment Range CMC 2, 3 (±) Comments Flow Meters Up to 10 GPM 0.083 % Max Machinery (9818-9) V. Mechanical Parameter/Equipment Range CMC 2, 3 (±) Comments Accelerometer Sensitivity 5 Hz to 3 kHz (3 to 6) kHz (6 to 9) kHz (9 to 12) kHz (12 to 15) kHz 0.94 % 1.7 % 2.5 % 3.2 % 4.0 % PCB K9155D11 (10834) Torque Wrenches (0.452 to 5.65) Nm (3.39 to 45.2) Nm (9.04 to 113) Nm (27.12 to 339) Nm (81.36 to 813.6) Nm (271.2 to 2712) Nm 1.8 % 0.55 % 0.42 % 0.37 % 0.36 % 0.35 % Snap-On TTC 2000 SYS (12739) Torque Transducer (0.3125 to 5) lbfꞏin (5 to 520) lbfꞏin (20 to 2000) lbfꞏin (1180 to 8850) lbfꞏin (1770 to 10 000) lbfꞏin 0.23 % F.S. 0.23 % 0.11 % 0.15 % 0.25 % 0"/20" beam (3943) w/ Troemner S22E-C (12683) 0"/20" beam (3943) w/ Troemner S22E-C (12683) 20" beam (3943) w/ Rice Lake weights (13087) 59" beam (4438) w/ Rice Lake weights (13087) Lebow 2111-10K (18655)
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6616.01) 02/20/2025 Page 10 of 12 Parameter/Equipment Range CMC 2, 3, 5 (±) Comments Torque Transducer (cont) (2 to 20) klbfꞏin (5 to 50) klbfꞏin (10 to 100) klbfꞏin (20 to 200) klbfꞏin 0.42 % + 16 lbfꞏin 0.045 % + 97 lbfꞏin 0.090 % + 170 lbfꞏin 0.0059 % + 370 lbfꞏin Interface 5411-20K (18497) Lebow 2112-50K (18653) Lebow 2112-100K (18652) Lebow 2113-200K (18718) Force ‒ Compression/Tension – Measure & Measuring Equipment (1 to 2000) gf (0.125 to 20) lbf (1 to 150) lbf (30 to 1000) lbf (250 to 5000) lbf (1000 to 10 000) lbf (2000 to 25 000) lbf (60 to 300) klbf 0.023 % + 1.1 gf 0.015 % + 0.0011 lbf 0.091 % 0.73 % 0.57 % 0.96 % 0.96 % 0.032 % + 390 lbf Troemner 507B (1024) Troemner S22E-C (12683) Rice Lake weights (13087) Lebow 3169-108 (18724) Interface 1610AJH-5K (18496) BLH Electronics C3P1 (17149) Interface 1620AJH-25K (19841) Load Cell Central – PSCG-300K (18546) Pressure ‒ Measuring Equipment (0.2 to 100) psig (100 to 3000) psig (500 to 5000) psig 0.070 % FS 0.35 % 0.064 % Eaton UPC 5100 BA (427) Amthor 460 (248) Budenburg 480M (4466) Pressure ‒ Measure (0.2 to 100) psig 0.069 % FS Eaton UPC 5100 BA (427) Scales Up to 2000 g Up to 27 lbs (1 to 150) lbs (50 to 500) lbs 0.078 % FS 0.87 % 0.091 % 0.12 % Troemner 507B (1024) Troemner S22E-C (12683) Rice Lake weights (13087) Rice Lake weights – 50 Lb set (2891)
11--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6616.01) 02/20/2025 Page 11 of 12 Parameter/Equipment Range CMC2 (±) Comments Non-Contact Tachometers (10 to 100 000) RPM 0.11 RPM Keysight 33612A, LED (12985) Contact Tachometers (1 to 7000) RPM 1.6 RPM Hewlett Packard 5512-A (497) VI. Thermodynamics Parameter/Equipment Range CMC 2, 5 (±) Comments Temperature – Measure (-40 to 120) °C 1.1 °C Vaisala HMT330 (9874) Humidity – Measure (15 to 95) % RH 4.0 % RH Vaisala HMT330 (9874) Infrared Thermometers (35 to 215) °C 2.2 °C Omega BB702 (9358) VII. Time & Frequency Parameter/Equipment Range CMC 2, 5 (±) Comments Frequency ‒ Generate 1 kHz to 20 MHz 2.7 µHz/Hz + 1.6 µHz Keysight 33612A (12985) Frequency ‒ Measure 5 Hz to 20 MHz 8.5 µHz/Hz + 1600 µHz Fluke 1900A (4642) ________________________________ 1 This laboratory does not offer commercial calibration service.
10 to 100000 RPM
12

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6616.01) 02/20/2025 Page 12 of 12 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 In the statement of CMC, percentages are percentage of reading, unless otherwise indicated. 4 L is the numerical value of the nominal length of the device measured in inches or in meters, corresponding to the system of units used in the uncertainty. 5 The type of instrument or material being calib rated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 6 This scope meets A2LA’s P112 Flexible Scope Policy. 7 The stated measured values are determined usi ng the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a fraction/percentage of the reading plus a fixed floor specification.
13

Extracted from the scope document; tables may not line up. View scope for the original.

For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation. Accredited Laboratory A2LA has accredited NEXTEER CALIBRATION LAB Saginaw, MI for technical competence in the field of Calibration This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This laboratory also meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 20th day of February 2025. __ _____________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 6616.01 Valid to August 31, 2026

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

3900 Holland Rd, Saginaw, MI, 48601, US

43.42004, -83.94904

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.