Platco
32450 English Turn, 44012, Avon Lake, OH, United States
Visit website- Scope lines
- 3
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 3 scope lines.
A2LA certificate 1554.01 · 3 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1554.01) Revised 2/2/2026 Page 1 of 2
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
PLATCO
32450 English Turn
Avon Lake, OH 44012
Richard Frye Phone: 440 835 1364
CALIBRATION
Valid To: December 31, 2026 Certificate Number: 1554.01
In recognition of the successful completion of the A2LA evaluation process (including an assessment of
the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is
granted to this laboratory to perform the following calibrations1, 4:
I. Dimensional
Parameter/Equipment
Range
CMC2 (±)
Comments
Surface Plates3 –
Flatness
Repeat Reading
(4 x 6) in to (8 x 12) in
(10 × 8) in to (36 × 36) in
Up to D = 480
0.002 in
37 µin
32 µin
23√D µin
23 µin
Custom tram with
planekator
Planekator
Autocollimator,
D is the nominal
length of the diagonal
in inches
Repeat-o-meter
____________________________________________
1 This laboratory offers commercial calibration service and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration. | ||
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1554.01) Revised 2/2/2026 Page 2 of 2
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 3 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.