Siemens Aktiengesellschaft Testing Laboratory Medium Voltage Frankfurt am Main
Carl-Benz-Straße 22, 60386, Frankfurt am Main, Germany
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
No contact information available
Open DAKKS register entryWork at Siemens Aktiengesellschaft Testing Laboratory Medium Voltage Frankfurt am Main?
Claim this profile to keep it accurate.
Register record
- DAKKSRefreshed
- D-PL-11055-09-00Active
Accredited standards
25Our reading of the DAKKS scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.
IEC 62271 series
IEC 62271-1Name not checked yet
IEC 61180:2016-06; IEC 62262: 2002-02 + AMD1: 2021-09; IEC 62271-1: 2017-07 + AMD1: 2021-10; IEC 62271-100: 2021-07; IEC 62271-102: 2018-05 + AMD1: 2022-04
IEC 62271-100Name not checked yet
IEC 61180:2016-06; IEC 62262: 2002-02 + AMD1: 2021-09; IEC 62271-1: 2017-07 + AMD1: 2021-10; IEC 62271-100: 2021-07; IEC 62271-102: 2018-05 + AMD1: 2022-04
IEC 62271-102Name not checked yet
IEC 61180:2016-06; IEC 62262: 2002-02 + AMD1: 2021-09; IEC 62271-1: 2017-07 + AMD1: 2021-10; IEC 62271-100: 2021-07; IEC 62271-102: 2018-05 + AMD1: 2022-04
IEC 62271-103Name not checked yet
IEC 62271-103: 2021-05; IEC 62271-105: 2021-06; IEC 62271-106: 2021-04; IEC 62271-200: 2021-05; IEC 62271-201:2014-03; IEC 62271-202:2014-03; IEC CDV 62271-207: 2022-03
IEC 62271-105Name not checked yet
IEC 62271-103: 2021-05; IEC 62271-105: 2021-06; IEC 62271-106: 2021-04; IEC 62271-200: 2021-05; IEC 62271-201:2014-03; IEC 62271-202:2014-03; IEC CDV 62271-207: 2022-03
IEC 62271-106Name not checked yet
IEC 62271-103: 2021-05; IEC 62271-105: 2021-06; IEC 62271-106: 2021-04; IEC 62271-200: 2021-05; IEC 62271-201:2014-03; IEC 62271-202:2014-03; IEC CDV 62271-207: 2022-03
IEC 62271-200Name not checked yet
IEC 62271-103: 2021-05; IEC 62271-105: 2021-06; IEC 62271-106: 2021-04; IEC 62271-200: 2021-05; IEC 62271-201:2014-03; IEC 62271-202:2014-03; IEC CDV 62271-207: 2022-03
IEC 62271-201Name not checked yet
IEC 62271-103: 2021-05; IEC 62271-105: 2021-06; IEC 62271-106: 2021-04; IEC 62271-200: 2021-05; IEC 62271-201:2014-03; IEC 62271-202:2014-03; IEC CDV 62271-207: 2022-03
IEC 62271-202Name not checked yet
IEC 62271-103: 2021-05; IEC 62271-105: 2021-06; IEC 62271-106: 2021-04; IEC 62271-200: 2021-05; IEC 62271-201:2014-03; IEC 62271-202:2014-03; IEC CDV 62271-207: 2022-03
IEC 62271-213Name not checked yet
IEC/TS 62271-210:2013-02; IEC 62271-213:2021-06; IEC/TS 62271-304:2019-03; IEC 62505-1:2016-02; IEC 62505-2:2016-02; IEEE C37.09: 2018; IEEE C37.100.1: 2018; IEEE C37.20.2:2015; IEEE C37.20.3:2013
IEC 60068 series
IEC 60068-2-1Environmental testing - Part 2-1: Tests - Test A: Cold
CSA C22.2 No 31:2018-01; CSA-C22.2 No. 58:1989-05; CSA C22.2 No. 193:1986-05; IEC 60060-1:2010-09; IEC 60068-2-1:2007-03; IEC 60068-2-11: 2021-03; IEC 60068-2-14:2009-01; IEC 60068-2-17:1994-07; IEC 60068-2-2:2007-07; IEC 60068-2-30:2005-08; IEC 60068-2-52: 2017-11; IEC 60068-2-78:2012-10; IEC 60282-1: 2020-04; IEC 60529:2013-08
IEC 60068-2-2Environmental testing - Part 2-2: Tests - Test B: Dry heat
CSA C22.2 No 31:2018-01; CSA-C22.2 No. 58:1989-05; CSA C22.2 No. 193:1986-05; IEC 60060-1:2010-09; IEC 60068-2-1:2007-03; IEC 60068-2-11: 2021-03; IEC 60068-2-14:2009-01; IEC 60068-2-17:1994-07; IEC 60068-2-2:2007-07; IEC 60068-2-30:2005-08; IEC 60068-2-52: 2017-11; IEC 60068-2-78:2012-10; IEC 60282-1: 2020-04; IEC 60529:2013-08
IEC 60068-2-11Environmental testing - Part 2-11: Tests - Test Ka: Salt mist
CSA C22.2 No 31:2018-01; CSA-C22.2 No. 58:1989-05; CSA C22.2 No. 193:1986-05; IEC 60060-1:2010-09; IEC 60068-2-1:2007-03; IEC 60068-2-11: 2021-03; IEC 60068-2-14:2009-01; IEC 60068-2-17:1994-07; IEC 60068-2-2:2007-07; IEC 60068-2-30:2005-08; IEC 60068-2-52: 2017-11; IEC 60068-2-78:2012-10; IEC 60282-1: 2020-04; IEC 60529:2013-08
IEC 60068-2-14Environmental testing - Part 2-14: Tests - Test N: Change of temperature
CSA C22.2 No 31:2018-01; CSA-C22.2 No. 58:1989-05; CSA C22.2 No. 193:1986-05; IEC 60060-1:2010-09; IEC 60068-2-1:2007-03; IEC 60068-2-11: 2021-03; IEC 60068-2-14:2009-01; IEC 60068-2-17:1994-07; IEC 60068-2-2:2007-07; IEC 60068-2-30:2005-08; IEC 60068-2-52: 2017-11; IEC 60068-2-78:2012-10; IEC 60282-1: 2020-04; IEC 60529:2013-08
IEC 60068-2-17Name not checked yet
CSA C22.2 No 31:2018-01; CSA-C22.2 No. 58:1989-05; CSA C22.2 No. 193:1986-05; IEC 60060-1:2010-09; IEC 60068-2-1:2007-03; IEC 60068-2-11: 2021-03; IEC 60068-2-14:2009-01; IEC 60068-2-17:1994-07; IEC 60068-2-2:2007-07; IEC 60068-2-30:2005-08; IEC 60068-2-52: 2017-11; IEC 60068-2-78:2012-10; IEC 60282-1: 2020-04; IEC 60529:2013-08
IEC 60068-2-30Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
CSA C22.2 No 31:2018-01; CSA-C22.2 No. 58:1989-05; CSA C22.2 No. 193:1986-05; IEC 60060-1:2010-09; IEC 60068-2-1:2007-03; IEC 60068-2-11: 2021-03; IEC 60068-2-14:2009-01; IEC 60068-2-17:1994-07; IEC 60068-2-2:2007-07; IEC 60068-2-30:2005-08; IEC 60068-2-52: 2017-11; IEC 60068-2-78:2012-10; IEC 60282-1: 2020-04; IEC 60529:2013-08
IEC 60068-2-52Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution)
CSA C22.2 No 31:2018-01; CSA-C22.2 No. 58:1989-05; CSA C22.2 No. 193:1986-05; IEC 60060-1:2010-09; IEC 60068-2-1:2007-03; IEC 60068-2-11: 2021-03; IEC 60068-2-14:2009-01; IEC 60068-2-17:1994-07; IEC 60068-2-2:2007-07; IEC 60068-2-30:2005-08; IEC 60068-2-52: 2017-11; IEC 60068-2-78:2012-10; IEC 60282-1: 2020-04; IEC 60529:2013-08
IEC 60068-2-78Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
CSA C22.2 No 31:2018-01; CSA-C22.2 No. 58:1989-05; CSA C22.2 No. 193:1986-05; IEC 60060-1:2010-09; IEC 60068-2-1:2007-03; IEC 60068-2-11: 2021-03; IEC 60068-2-14:2009-01; IEC 60068-2-17:1994-07; IEC 60068-2-2:2007-07; IEC 60068-2-30:2005-08; IEC 60068-2-52: 2017-11; IEC 60068-2-78:2012-10; IEC 60282-1: 2020-04; IEC 60529:2013-08
IEC
IEC 60060-1Name not checked yet
CSA C22.2 No 31:2018-01; CSA-C22.2 No. 58:1989-05; CSA C22.2 No. 193:1986-05; IEC 60060-1:2010-09; IEC 60068-2-1:2007-03; IEC 60068-2-11: 2021-03; IEC 60068-2-14:2009-01; IEC 60068-2-17:1994-07; IEC 60068-2-2:2007-07; IEC 60068-2-30:2005-08; IEC 60068-2-52: 2017-11; IEC 60068-2-78:2012-10; IEC 60282-1: 2020-04; IEC 60529:2013-08
IEC 60282-1Name not checked yet
CSA C22.2 No 31:2018-01; CSA-C22.2 No. 58:1989-05; CSA C22.2 No. 193:1986-05; IEC 60060-1:2010-09; IEC 60068-2-1:2007-03; IEC 60068-2-11: 2021-03; IEC 60068-2-14:2009-01; IEC 60068-2-17:1994-07; IEC 60068-2-2:2007-07; IEC 60068-2-30:2005-08; IEC 60068-2-52: 2017-11; IEC 60068-2-78:2012-10; IEC 60282-1: 2020-04; IEC 60529:2013-08
IEC 60529Degrees of protection provided by enclosures (IP Code)
CSA C22.2 No 31:2018-01; CSA-C22.2 No. 58:1989-05; CSA C22.2 No. 193:1986-05; IEC 60060-1:2010-09; IEC 60068-2-1:2007-03; IEC 60068-2-11: 2021-03; IEC 60068-2-14:2009-01; IEC 60068-2-17:1994-07; IEC 60068-2-2:2007-07; IEC 60068-2-30:2005-08; IEC 60068-2-52: 2017-11; IEC 60068-2-78:2012-10; IEC 60282-1: 2020-04; IEC 60529:2013-08
IEC 61180Name not checked yet
IEC 61180:2016-06; IEC 62262: 2002-02 + AMD1: 2021-09; IEC 62271-1: 2017-07 + AMD1: 2021-10; IEC 62271-100: 2021-07; IEC 62271-102: 2018-05 + AMD1: 2022-04
IEC 62262Name not checked yet
IEC 61180:2016-06; IEC 62262: 2002-02 + AMD1: 2021-09; IEC 62271-1: 2017-07 + AMD1: 2021-10; IEC 62271-100: 2021-07; IEC 62271-102: 2018-05 + AMD1: 2022-04
IEC 62505-1Name not checked yet
IEC/TS 62271-210:2013-02; IEC 62271-213:2021-06; IEC/TS 62271-304:2019-03; IEC 62505-1:2016-02; IEC 62505-2:2016-02; IEEE C37.09: 2018; IEEE C37.100.1: 2018; IEEE C37.20.2:2015; IEEE C37.20.3:2013
IEC 62505-2Name not checked yet
IEC/TS 62271-210:2013-02; IEC 62271-213:2021-06; IEC/TS 62271-304:2019-03; IEC 62505-1:2016-02; IEC 62505-2:2016-02; IEEE C37.09: 2018; IEEE C37.100.1: 2018; IEEE C37.20.2:2015; IEEE C37.20.3:2013
Scope as published by DAKKS
6 lines
ISO/IEC 17025
ActiveD-PL-11055-09-00
Accredited scope, certificate D-PL-11055-09-00
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | electrical | DIN EN ISO/IEC 17025:2018 | - | - |
| 2 | electrical | CSA C22.2 No 31:2018-01; CSA-C22.2 No. 58:1989-05; CSA C22.2 No. 193:1986-05; IEC 60060-1:2010-09; IEC 60068-2-1:2007-03; IEC 60068-2-11: 2021-03; IEC 60068-2-14:2009-01; IEC 60068-2-17:1994-07; IEC 60068-2-2:2007-07; IEC 60068-2-30:2005-08; IEC 60068-2-52: 2017-11; IEC 60068-2-78:2012-10; IEC 60282-1: 2020-04; IEC 60529:2013-08 | - | - |
| 3 | electrical | IEC 61180:2016-06; IEC 62262: 2002-02 + AMD1: 2021-09; IEC 62271-1: 2017-07 + AMD1: 2021-10; IEC 62271-100: 2021-07; IEC 62271-102: 2018-05 + AMD1: 2022-04 | - | - |
| 4 | electrical | IEC 62271-103: 2021-05; IEC 62271-105: 2021-06; IEC 62271-106: 2021-04; IEC 62271-200: 2021-05; IEC 62271-201:2014-03; IEC 62271-202:2014-03; IEC CDV 62271-207: 2022-03 | - | - |
| 5 | electrical | IEC/TS 62271-210:2013-02; IEC 62271-213:2021-06; IEC/TS 62271-304:2019-03; IEC 62505-1:2016-02; IEC 62505-2:2016-02; IEEE C37.09: 2018; IEEE C37.100.1: 2018; IEEE C37.20.2:2015; IEEE C37.20.3:2013 | - | - |
| 6 | electrical | IEEE C37.20.4:2013; IEEE C37.20.7: 2017; IEEE C37.20.9: 2019; NEMA C37.55: 2020; NEMA C37.57:2003; NEMA C37.58: 2020; NEMA/ANSI C37.54:2002 | - | 1 to 52 kV |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the DAKKS register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.