China

Meggitt (Xiamen) Sensors & Controls

230 South 5 Gaoqi Road, Xiamen 361006, People's Republic of China, Xiamen 361006, China

Visit website
A2LA 2602.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
3
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 3 scope lines.

A2LA certificate 2602.01 · 3 lines

LineMethodMatrixRange
1

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2602.01) 10/01/2024 Page 1 of 2 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 MEGGITT (XIAMEN) SENSORS & CONTROLS CO. LTD 美捷特 (厦门) 传感器件有限公司 230 South 5 Gaoqi Road Xiamen 361006 PEOPLE’S REPUBLIC OF CHINA Amanda Wang Phone: +86 0592 8062221 CALIBRATION Valid To: November 30, 2026 Certificate Number: 2602.01 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations1, 5: I. Mechanical Parameter/Equipment Range3 CMC2, 4 (±) Comments Acceleration Sensitivity – Reference Frequency Frequency Response 100 Hz, 10 g (2 to 15) V (20 to < 100) Hz, (0.25 to 10) g (2 to 15) V (100 to 2500) Hz, 10 g (2 to 15) V (> 2500 to 10 000) Hz, 10 g (2 to 15) V (> 10 000 to 20 000) Hz, 10 g (2 to 15) V 1.0 % of rdg 1.3 % of rdg 1.7 % of rdg 2.1 % of rdg 4.0 % of rdg Automated accelerometer calibration system
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2602.01) 10/01/2024 Page 2 of 2 Parameter/Equipment Range3 CMC2, 4 (±) Comments Acceleration Sensitivity– Transverse Sensitivity Up to 100% 13.2 Hz, 8.9 g 1.3 % of rdg Transverse sensitivity console with Endevco crosstalk system manual rotation Charge Sensitivity Up to 100 pC/g (20 to 2000) g, (> 2000 to 10 000) g 2.6 % of rdg 3.7 % of rdg Endevco 2925 exciter with 2270M8 ____________________________________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 The symbol g represents gravitational units. One g equals 9.80665 m/s2. 4 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 5 This scope meets A2LA’s P112 Flexible Scope Policy.
to 100 %
3

Extracted from the scope document; tables may not line up. View scope for the original.

For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation. Accredited Laboratory A2LA has accredited MEGGITT (XIAMEN) SENSORS & CONTROLS CO. LTD Xiamen, PEOPLE’S REPUBLIC OF CHINA for technical competence in the field of Calibration This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This laboratory also meets the requirements of R205 – Specific Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competen ce for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 1st day of October 2024. _______________________ Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 2602.01 Valid to November 30, 2026

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.