leggett & platt
Detroit, MI, United States
- Accredited standards
- 14
- A2LA certificates
- 2
- Sites in our directory
- 2
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 14 standard numbers and the 13 official names we hold. When no standard matches, it searches the method text of every scope line.
IEC 60068 series4
IEC 60068-2-27Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
IEC 60068-2-38Environmental testing - Part 2-38: Tests - Test Z/AD: Composite temperature/humidity cyclic test
IEC 60068-2-64Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance
IEC 60068-2-78Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
ISO3
ISO 10605Road vehicles - Test methods for electrical disturbances from electrostatic discharge
ISO 11452-1Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 1: General principles and terminology
ISO 11452-4Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 4: Harness excitation methods
ISO 16750 series3
ISO 16750-2Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 2: Electrical loads
ISO 16750-3Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 3: Mechanical loads
ISO 16750-4Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 4: Climatic loads
ISO 7637 series3
ISO 7637-1Road vehicles - Electrical disturbances from conduction and coupling - Part 1: Vocabulary and general considerations
ISO 7637-2Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only
ISO 7637-3Road vehicles - Electrical disturbances from conduction and coupling - Part 3: Electrical transient transmission by capacitive and inductive coupling via lines other than supply lines
Other standards1
ASTM D4728
TL-6172; TL-6550; EPS-24126248; EPS-24138553; Ford CETP:00.00-E-412; ASTM D4728; FCA CS.00056; Ford CEPT: 00:00-E-412; GMW 31721; GMW 3191; Hyundai/KIA ES95400-10; IEC 60068-2-27; IEC 60068-2-64; ISO 16750-3; JDQ 53.3; JIS D 1601; MIL-STD-202 (G, H) Methods 204; MIL-STD-810 (G, H) Methods 514; IPC-TM-650 (Methods 2.1.1, 2.1.2, 2.1.5, and 2.1.10)
FCA CS.00056; Ford CEPT:00:00-E-412; GMW31721; GMW3191; USCAR-2; USCAR-21; MIL-STD-810 (G, H); MIL-STD-202 (G, H); JDQ 53.3; Hyundai/KIA ES95400-10; ISO 16750-4; IEC 60068-2-38; IEC 60068-2-78; EPS-24126248; EPS-24138553
ISO 10605 Amd 1 2014, Sections 8 and 9; ISO 10605:2008/Amd 1 2014, Sections 8 and 9; ISO 10605:2023; CISPR 25, Sections 6.3, 6.4 and 6.5; CISPR 25 (2016), Sections 6.3, 6.4 and 6.5; ISO 11452-1; ISO 11452-1 (2015); ISO 11452-4, Section 6.1; ISO 11452-4 (2011), Section 6.1; ISO 7637-1; ISO 7637-2; ISO 7637-2 (2004, 2011); ISO 7637-3; ISO 7637-3 (2016); ISO 16750-2, Sections 4.2, 4.3.1.2, 4.5, 4.6, 4.7, 4.8, 4.9 and 4.10.2; ISO 16750-2 2010-03, Sections 4.2, 4.3.1.2, 4.5, 4.6, 4.7, 4.8, 4.9 and 4.10.2; ISO 7637-2; ISO 7637-2 2004-06
Read from the A2LA scope documents we downloaded on 2026-08-05 and 2026-10-27. Register refreshed 2026-11-06.
Scope as published by A2LA
5 lines
ISO/IEC 17025
Active7230.01
The scope document we hold says it is valid until 2028-06-30.
Accredited scope, certificate 7230.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO 10605 Amd 1 2014, Sections 8 and 9; ISO 10605:2008/Amd 1 2014, Sections 8 and 9; ISO 10605:2023; CISPR 25, Sections 6.3, 6.4 and 6.5; CISPR 25 (2016), Sections 6.3, 6.4 and 6.5; ISO 11452-1; ISO 11452-1 (2015); ISO 11452-4, Section 6.1; ISO 11452-4 (2011), Section 6.1; ISO 7637-1; ISO 7637-2; ISO 7637-2 (2004, 2011); ISO 7637-3; ISO 7637-3 (2016); ISO 16750-2, Sections 4.2, 4.3.1.2, 4.5, 4.6, 4.7, 4.8, 4.9 and 4.10.2; ISO 16750-2 2010-03, Sections 4.2, 4.3.1.2, 4.5, 4.6, 4.7, 4.8, 4.9 and 4.10.2; ISO 7637-2; ISO 7637-2 2004-06 | DC Motor; DC Pump; Pneumatic Valve; Sensor; Electronic Control Unit (ECU); Lumbar System; Seat | - |
| 2 | ISO/IEC 17025:2017 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
ISO/IEC 17025
Active7230.02
The scope document we hold says it is valid until 2028-06-30.
Accredited scope, certificate 7230.02
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | FCA CS.00056; Ford CEPT:00:00-E-412; GMW31721; GMW3191; USCAR-2; USCAR-21; MIL-STD-810 (G, H); MIL-STD-202 (G, H); JDQ 53.3; Hyundai/KIA ES95400-10; ISO 16750-4; IEC 60068-2-38; IEC 60068-2-78; EPS-24126248; EPS-24138553 | air | -60 to 180 °C |
| 2 | TL-6172; TL-6550; EPS-24126248; EPS-24138553; Ford CETP:00.00-E-412; ASTM D4728; FCA CS.00056; Ford CEPT: 00:00-E-412; GMW 31721; GMW 3191; Hyundai/KIA ES95400-10; IEC 60068-2-27; IEC 60068-2-64; ISO 16750-3; JDQ 53.3; JIS D 1601; MIL-STD-202 (G, H) Methods 204; MIL-STD-810 (G, H) Methods 514; IPC-TM-650 (Methods 2.1.1, 2.1.2, 2.1.5, and 2.1.10) | - | - |
| 3 | ISO/IEC 17025:2017 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Other Locations
1 other site in this organization
Labs with overlapping accredited scope in United States
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.