CLO.MA. S.r.l. a socio unico
Viale Trieste, 87, 81054, San Prisco, Italy
Visit website- Accredited standards
- 3
- ACCREDIA certificate
- 1
- Sites in our directory
- 2
What this lab is accredited for
Our reading of the ACCREDIA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 3 standard numbers and the 2 official names we hold. When no standard matches, it searches the method text of every scope line.
APAT CNR IRSA 2030 Man 29 2003Conducibilità
DM 13/09/1999 SO n 185 GU n 248 21/10/1999 Met III.1
ISO 15705Water quality - Determination of the chemical oxygen demand index (ST-COD) - Small-scale sealed-tube methodExclusion
Limits written next to it
ISO 15705:2002 - escluso/except Il
APAT CNR IRSA 2030 Man 29 2003; APAT CNR IRSA 2060 Man 29 2003; APAT CNR IRSA 4140 B Man 29 2003; APAT CNR IRSA 3150 C Man 29 2003; APAT CNR IRSA 4090 A1 Man 29 2003; Rapporti ISTISAN 2007/31 pag 51 Met ISS BEC041; ISO 15705:2002
UNI CEI EN ISO/IEC 17025:2018; DM 13/09/1999 SO n 185 GU n 248 21/10/1999 Met III.1
Read from the scope as published by ACCREDIA. Register refreshed 2026-11-20.
Scope as published by ACCREDIA
2 lines
ISO/IEC 17025
Active02152
Accredited scope, certificate 02152
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | APAT CNR IRSA 2030 Man 29 2003; APAT CNR IRSA 2060 Man 29 2003; APAT CNR IRSA 4140 B Man 29 2003; APAT CNR IRSA 3150 C Man 29 2003; APAT CNR IRSA 4090 A1 Man 29 2003; Rapporti ISTISAN 2007/31 pag 51 Met ISS BEC041; ISO 15705:2002 | Waste water | See scope document |
| 2 | UNI CEI EN ISO/IEC 17025:2018; DM 13/09/1999 SO n 185 GU n 248 21/10/1999 Met III.1 | - | 1 to 13 unita di pH |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Other Locations
1 other site in this organization
Labs with overlapping accredited scope in Italy
- EOS LAB S.R.L.Foggia · ~109 kmACCREDIAShares 3 accredited methods and materialsAPAT CNR IRSA 2030 Man 29 2003DM 13/09/1999 SO n 185 GU n 248 21/10/1999 Met III.1Waste water
- HYDROLABFerrandina · ~195 kmACCREDIAShares 3 accredited methods and materialsAPAT CNR IRSA 2030 Man 29 2003DM 13/09/1999 SO n 185 GU n 248 21/10/1999 Met III.1Waste water
- SCAR LABS SRLSan Marco Evangelista · ~7 kmACCREDIAShares 2 accredited methods and materialsAPAT CNR IRSA 2030 Man 29 2003Waste water
- PollutionMaddaloni · ~10 kmACCREDIAShares 2 accredited methods and materialsAPAT CNR IRSA 2030 Man 29 2003Waste water
- NATURA S.r.l.Casoria · ~20 kmACCREDIAShares 2 accredited methods and materialsDM 13/09/1999 SO n 185 GU n 248 21/10/1999 Met III.1Waste water
Accreditation data refreshed from the ACCREDIA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ACCREDIA entry linked above.