United States

The Lubrizol Corporation

29400 Lakeland Blvd., 44092, Wickliffe, OH, United States

Visit website
A2LA 2115.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
7
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 7 scope lines.

A2LA certificate 2115.01 · 7 lines

LineMethodMatrixRange
1

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 2115.01) 12/5/2025 Page 1 of 6 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 THE LUBRIZOL CORPORATION 29400 Lakeland Boulevard Wickliffe, OH 44092 Mairin O’Donnell Phone: 440 347 5674 CALIBRATION Valid To: November 30, 2027 Certificate Number: 2115.01 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 6: I. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 3 (±) Comments DC Voltage – Generate (0 to 120) mV 120 mV to 1.2 V (1.2 to 12) V (12 to 120) V (120 to 1000) V 13 µV/V + 0.96 µV 8.7 µV/V + 1.2 µV 9.2 µV/V + 10 µV 12 µV/V + 100 µV 13 µV/V + 1.2 mV Fluke 5550A DC Voltage – Measure (0 to 200) mV 200 mV to 2 V (2 to 20) V (20 to 200) V (200 to 1000) V 6.9 µV/V + 0.20 µV 3.0 µV/V + 0.30 µV 3.1 µV/V + 0.50 µV 4.4 µV/V + 30 µV 4.7 µV/V + 500 µV Fluke 8588A DC Current – Generate (0 to 120) µA 120 µA to 1.2 mA (1.2 to 12) mA (12 to 120) mA 120 mA to 3 A (3 to 12) A (12 to 30) A 110 µA/A + 7.2 nA 86 µA/A + 18 nA 86 µA/A + 96 nA 86 µA/A + 960 nA 290 µA/A + 180 µA 360 µA/A + 300 µA 860 µA/A + 600 µA Fluke 5550A
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 2115.01) 12/5/2025 Page 2 of 6 Parameter/Equipment Range CMC2, 3 (±) Comments DC Current – Measure (0 to 200) µA 200 µA to 2 mA (2 to 20) mA (20 to 200) mA 200 mA to 2 A (2 to 20) A (20 to 30) A 11 µA/A + 0.4 nA 9.7 µA/A + 4.0 nA 11 µA/A + 4.0 nA 36 µA/A + 1.0 µA 430 µA/A + 100 µA 190 µA/A + 800 µA 500 µA/A + 4.4 mA Fluke 8588A DC Resistance – Generate (0 to 12) Ω (12 to 120) Ω 120 Ω to 1.2 kΩ (1.2 to 12) kΩ (12 to 120) kΩ 120 kΩ to 1.2 MΩ 33 µΩ/Ω + 1.0 mΩ 24 µΩ/Ω + 1.0 mΩ 23 µΩ/Ω + 2.0 mΩ 24 µΩ/Ω + 20 mΩ 23 µΩ/Ω + 200 mΩ 26 µΩ/Ω + 2.0 Ω Fluke 5550A DC Resistance – Measure (0 to 2) Ω (2 to 20) Ω (20 to 200) Ω 200 Ω to 2 kΩ (2 to 20) kΩ (20 to 200) kΩ 200 kΩ to 2 MΩ (2 to 20) MΩ (20 to 200) MΩ 200 MΩ to 1 GΩ 36 µΩ/Ω + 4.0 µΩ 8.8 µΩ/Ω + 14 µΩ 7.5 µΩ/Ω + 50 µΩ 7.3 µΩ/Ω + 500 µΩ 7.6 µΩ/Ω + 5 mΩ 7.8 µΩ/Ω + 50 mΩ 9.4 µΩ/Ω + 8.2 Ω 34 µΩ/Ω + 100 Ω 98 µΩ/Ω + 10 kΩ 520 µΩ /Ω + 1.0 MΩ Fluke 8588A Electrical Calibration of Thermocouples – Generate & Measure Type E Type J (-250 to -150) °C (-150 to -25) °C (-25 to 350) °C (350 to 650) °C (650 to 1000) °C (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C 0.33 °C 0.15 °C 0.14 °C 0.17 °C 0.20 °C 0.22 °C 0.15 °C 0.14 °C 0.15 °C 0.19 °C Fluke 5550A
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 2115.01) 12/5/2025 Page 3 of 6 Parameter/Equipment Range CMC2 (±) Comments Electrical Calibration of Thermocouples – Generate & Measure (cont) Type K Type T (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 1000) °C (1000 to 1372) °C (-250 to -150) °C (-150 to 0) °C (0 to 120) °C (120 to 400) °C 0.24 °C 0.15 °C 0.14 °C 0.20 °C 0.29 °C 0.48 °C 0.20 °C 0.15 °C 0.14 °C Fluke 5550A Electrical Calibration of RTDs – Generate & Measure Pt 385, 100 Ω (-80 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (630 to 800) °C 0.040 °C 0.056 °C 0.074 °C 0.084 °C 0.093 °C 0.18 °C 4 wire compensation II. Fluid Quantities Parameter/Equipment Range CMC2, 4, 5 (±) Comments Gas Flow – Measure Up to 100 sccm Up to 5 slm Up to 40 slm Up to 80 slm Up to 300 slm 0.26 % 0.23 % 0.23 % 0.33 % 0.44 % DHI Molbox 1 system with laminar element Fluke Molbox S sonic element Fluid Flow – Measure Up to 1.367 L/min Up to 18.17 L/min Up to 226.7 L/min Up to 725.8 L/min 0.16 % + 0.09 mL/m 0.16 % + 0.09 mL/m 0.16 % + 0.09 mL/m 0.16 % + 0.09 mL/m Coriolis flow meters
4ISO-8655-6-50 to 700 g
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 2115.01) 12/5/2025 Page 5 of 6 Parameter/Equipment Range CMC2, 4, 5 (±) Comments Torque – Measure (0 to 203) N·m (0 to 445) N·m (0 to 2405) N·m (0 to 4747) N·m 0.010 % + 0.053 N·m 0.010 % + 0.092 N·m 0.010 % + 1.8 N·m 0.023 % + 8.9 N·m Class F weights dynamometer Class F weights & moment arm MSI 3360 crane scale Force – Compression & Tension, Measuring Equipment (0 to 10 200) lbf (0 to 1000) lbf 0.021 % of full scale 0.031 % of full scale 10.2 k proving ring Load cell IV. Thermodynamics Parameter/Equipment Range CMC2, 5 (±) Comments Temperature – Measuring Equipment (-45 to 100) °C (100 to 200) °C (200 to 300) °C 0.0064 °C 0.0076 °C 0.011 °C Fluke 1594A & Fluke 5628-12 w/ Fluke 7341 oil bath Fluke 1594A & Fluke 5628-12 w/ Fluke 6331 oil bath Temperature – Measuring Equipment, Fixed Points 0.00 °C 0.01 °C 156.63 °C 0.0075 °C 0.0067 °C 0.30 °C Ice point Hart TPW cell 5901 Reference material indium PRT (-45 to 58) °C (58 to 300) °C (30 to 240) °C (240 to 400) °C 0.0066 °C 0.013 °C 0.016 °C 0.028 °C Fluke 1594A, Fluke 5628 & oil bath Fluke 1594A, Fluke 5628 & dry block Relative Humidity3 – Measuring Equipment (10 to 95) % RH 0.53 % RH Thunder Scientific 2500
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 2115.01) 12/5/2025 Page 6 of 6 Parameter/Equipment Range CMC2, 5 (±) Comments Dew Point – Measuring Equipment (0 to 50) °C 0.15 °C Thunder Scientific 2500 V. Time & Frequency Parameter/Equipment Range CMC2, 5 (±) Comments Frequency – Measure & Measuring Equipment (0.01 to 120) Hz 120 Hz to 1.2 kHz (1.2 to 12) kHz (12 to 120) kHz 120 kHz to 1.2 MHz (1.2 to 2.0) MHz 0.000 20 Hz 0.0022 Hz 0.021 Hz 0.22 Hz 2.0 Hz 2.8 Hz Fluke 5550A & PM6690 Time – Measure (0 to 86 400) s 0.13 s NIST (303 499 7111) ____________________________________________ 1 This laboratory is not normally available for commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavio r of the customer’s device and to influences from the circumstances of the specific calibration. 3 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as eithe r a specific value that covers the full range or as a fraction/percentage of the reading plus a fixed floor specification. 4 In the statement of CMC, percent refers to a percent of reading unless otherwise noted. 5 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 6 This scope meets A2LA’s P112 Flexible Scope Policy.
7ISO/IEC 17025:2017; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

29400 Lakeland Blvd., Wickliffe, OH, 44092, US

41.60533, -81.45345

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.