Registers refreshed 2026-11-20.See refresh dates
Poland

"Zielonogórskie Wodociągi i Kanalizacja"

ul. Zawada-Kożuchowska 35, 66-001, Zielona Góra, Poland

PCA AB 1006ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
33
PCA certificate
1
Site in our directory
1
PCA accredited scope

What this lab is accredited for

Our reading of the PCA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 33 standard numbers and the 33 official names we hold. When no standard matches, it searches the method text of every scope line.

ISO23
ISO 5664Water quality - Determination of ammonium - Distillation and titration method
ISO 5815-1Water quality - Determination of biochemical oxygen demand after n days (BODn) - Part 1: Dilution and seeding method with allylthiourea addition
ISO 6058Water quality - Determination of calcium content - EDTA titrimetric method
ISO 6059Water quality - Determination of the sum of calcium and magnesium - EDTA titrimetric method
ISO 6222Water quality - Enumeration of culturable micro-organisms - Colony count by inoculation in a nutrient agar culture medium
ISO 6332Water quality - Determination of iron - Spectrometric method using 1,10-phenanthroline
ISO 6878Water quality - Determination of phosphorus - Ammonium molybdate spectrometric method
ISO 7887Water quality - Examination and determination of colour
ISO 7899-2Water quality - Detection and enumeration of intestinal enterococci - Part 2: Membrane filtration method
ISO 8467Water quality - Determination of permanganate index
ISO 9280Water quality - Determination of sulfate - Gravimetric method using barium chloride
ISO 9297Water quality - Determination of chloride - Silver nitrate titration with chromate indicator (Mohr's method)
Show all 23
ISO 9308-1Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 1: Membrane filtration method for waters with low bacterial background flora
ISO 9308-2Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 2: Most probable number method
ISO 9963-1Water quality - Determination of alkalinity - Part 1: Determination of total and composite alkalinity
ISO 10304-1Water quality - Determination of dissolved anions by liquid chromatography of ions - Part 1: Determination of bromide, chloride, fluoride, nitrate, nitrite, phosphate and sulfate
ISO 10304-4Water quality - Determination of dissolved anions by liquid chromatography of ions - Part 4: Determination of chlorate, chloride and chlorite in water with low contamination
ISO 10523Water quality - Determination of pH
ISO 11885Water quality - Determination of selected elements by inductively coupled plasma optical emission spectrometry (ICP-OES)
ISO 14189Water quality - Enumeration of Clostridium perfringens - Method using membrane filtration
ISO 15705Water quality - Determination of the chemical oxygen demand index (ST-COD) - Small-scale sealed-tube method
ISO 16266Water quality - Detection and enumeration of Pseudomonas aeruginosa - Method by membrane filtration
ISO 19458Water quality - Sampling for microbiological analysis
EN7
EN 872Water quality - Determination of suspended solids - Method by filtration through glass fibre filters
EN 1484Water analysis - Guidelines for the determination of total organic carbon (TOC) and dissolved organic carbon (DOC)
EN 1622Water quality - Determination of the threshold odour number (TON) and threshold flavour number (TFN)
EN 1899-2Water quality - Determination of biochemical oxygen demand after n days (BODn) - Part 2: Method for undiluted samples
EN 25663Water quality - Determination of Kjeldahl nitrogen - Method after mineralization with selenium
EN 26777Water quality - Determination of nitrite - Molecular absorption spectrometric method
EN 27888Water quality - Determination of electrical conductivity
ISO 5667 series3
ISO 5667-5Water quality - Sampling - Part 5: Guidance on sampling of drinking water from treatment works and piped distribution systems
ISO 5667-10Water quality - Sampling - Part 10: Guidance on sampling of waste water
ISO 5667-11Water quality - Sampling - Part 11: Guidance on sampling of groundwaters

Read from the PCA scope document we downloaded on 2026-03-13. Register refreshed 2026-11-20.

Scope as published by PCA

7 lines
PCA

ISO/IEC 17025

Active

AB 1006

The scope document we hold says it is valid until 2029-03-09.

View on PCA

Accredited scope, certificate AB 1006

LineMethodMatrixRange
1-Drinking water
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

PCA Zakres akredytacji Nr AB 1006 Scope of accreditation No. AB 1006 ZAKRES AKREDYTACJI LABORATORIUM BADAWCZEGO SCOPE OF ACCREDITATION FOR TESTING LABORATORY Nr/No. AB 1006 wydany przez / issued by POLSKIE CENTRUM AKREDYTACJI 01-382 Warszawa, ul. Szczotkarska 42 Wydanie/Issue 21 z/of 15.01.2026 p.o. KIEROWNIK A DZIAŁU AKREDYTACJI BADAŃ CHEMICZNYCH MARCIN BEKAS Niniejszy dokument jest załącznikiem do Certyfikatu Akredytacji Nr AB 1006 z dnia 02.09.2020 r. Cykl akredytacji od 10.02.2025 r. do 09.03.2029 r. Status akredytacji oraz aktualność zakresu akredytacji można potwierdzić na stronie internetowej PCA www.pca.gov.pl This document is an annex to accreditation certificate No. AB 1006 of 02.09.2020 Accreditation cycle from 10.02.2025 to 09.03.2029 The status of accreditation and validity of the scope of accreditation can be confirmed at PCA website www.pca.gov.pl Wydanie nr / Issue No. 21, 15.01.2026 1/8 Nazwa i adres / Name and address „ZIELONOGÓRSKIE WODOCIĄGI I KANALIZACJA” Sp. z o.o. ul. Zjednoczenia 110 A 65-120 Zielona Góra LABORATORIUM BADANIA WÓD I ŚCIEKÓW ul. Zawada-Kożuchowska 35 66-001 Zielona Góra Kod identyfikacyjny / Identification code *) Dziedzina i przedmiot badań / Field of testing and item: - C/28/P; C/29/P; C/30/P - N/28/P; N/29/P; N/30/P - K28/P; K/29/P - Q/28/P; Q/29/P - Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków / Chemical tests and sampling of water, drinking water, sewage, - Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków/ Tests of physical properties and sampling of water, drinking water, sewage, - Badania mikrobiologiczne i pobieranie próbek wody, wody do spożycia przez ludzi / Microbiological tests and sampling of water, drinking water - Badania sensoryczne i pobieranie próbek wody, wody do spożycia przez ludzi / Sensory tests and sampling of water, drinking water Wersja strony/Page version: A *) Kod identyfikacyjny zgodnie z załącznikiem do dokumentu DAB-07 dostępnym na stronie internetowej www .pca.gov.pl / The identification code according to the Annex to document DAB-07, available at PCA website www.pca .gov.pl AB 1006
-
2PN-EN ISO 5667-11:2017-10; PB-07; PN-EN ISO 9963-1:2001+ Ap1:2004; PN-EN 872:2007+Ap1:2007; PN-ISO 5667-5:2017-10; PN-EN 1622:2006; PN-EN ISO 10304-4:2022-08; PN-EN 27888:1999; PN-ISO 9297:1994; PN-82/C-04576.08; PN-EN 26777:1999Drinking waterSee scope document
3PN-ISO 6059:1999; PN-ISO 6058:1999; PB-11; PN-92/C-04590/03; PN-EN ISO 10304-1:2009; PN-EN ISO 7887:2012+Ap1:2015-06; PN-EN 1484:1999; PN-EN ISO 10523:2012; PB-06; PN-EN ISO 10304-1:2009; PN-ISO 6332:2001 pkt. 7.2; PN-ISO 6332:2001/Ap1:2016-06; PN-EN ISO 8467:2001; PB-02Drinking waterSee scope document
4PB-32; PN-EN ISO 10304-1:2009Drinking waterSee scope document
5PN-EN ISO 19458:2007; PB-07; PN-EN ISO 6222:2004; PN-EN ISO 9308-1:2014-12 +A1:2017-04; PN-EN ISO 7899-2:2004; PN-EN ISO 14189:2016-10; PN-EN ISO 16266:2009; PN-EN ISO 9308-2:2014-06Drinking water2 to 60 °C
6PN-ISO 5667-10:2021-11; PN-EN ISO 6878:2006 p.4+Ap1:2010+Ap2:2010; PN-EN ISO 10523:2012; PN-EN 872:2007+Ap1:2007; PN-EN 27888:1999; PN-ISO 15705:2005; PN-ISO 5664:2002; PN-EN ISO 5815-1:2019-12; PN-EN 26777:1999; PN-ISO 9297:1994; PN-EN 25663:2001Waste water2 to 60 °C
7PN-EN ISO 11885:2009; PN-EN ISO 9280:2002; PB-35; PN-EN 25663:2001; PN-EN 1899-2:2002Waste waterSee scope document

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

ul. Zawada-Kożuchowska 35, Zielona Góra, 66-001, PL

51.93838, 15.50504

Open in Maps

Accreditation data refreshed from the PCA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the PCA entry linked above.