LABORATORIO MEDIOAMBIENTAL
Pol. Ind. Lorquí, C/ Molina, Nave 3, 30564, Lorquí, Spain
- Accredited standards
- 8
- ENAC certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the ENAC scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 8 standard numbers and the 8 official names we hold. When no standard matches, it searches the method text of every scope line.
EN 872Water quality - Determination of suspended solids - Method by filtration through glass fibre filters
EN 27888Water quality - Determination of electrical conductivity
ISO 5815-1Water quality - Determination of biochemical oxygen demand after n days (BODn) - Part 1: Dilution and seeding method with allylthiourea addition
ISO 6878Water quality - Determination of phosphorus - Ammonium molybdate spectrometric method
ISO 7027-1Water quality - Determination of turbidity - Part 1: Quantitative methods
ISO 10523Water quality - Determination of pH
ISO 11731Water quality - Enumeration of Legionella
ISO 15705Water quality - Determination of the chemical oxygen demand index (ST-COD) - Small-scale sealed-tube method
UNE-EN ISO 10523; UNE-EN 27888; UNE-EN ISO 7027-1; ASTM 1426-15; UNE-EN 872; UNE-EN ISO 5815-1; UNE-EN ISO 6878; ISO 15705
UNE-EN ISO 10523; UNE-EN 27888; UNE-EN ISO 7027-1; ASTM 1426-15; UNE-EN ISO/IEC 17025:2017
UNE-EN ISO 11731; LABMEDIOMIC034
Read from the scope as published by ENAC. Register refreshed 2026-10-10.
Scope as published by ENAC
3 lines
ISO/IEC 17025
Active1143/LE2076
Accredited scope, certificate 1143/LE2076
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | UNE-EN ISO 10523; UNE-EN 27888; UNE-EN ISO 7027-1; ASTM 1426-15; UNE-EN ISO/IEC 17025:2017 | Aguas de consumo; Aguas continentales tratadas; Aguas residuales; agua sanitaria; aguas de piscinas; torres de refrigeración y condensadores evaporativos; aguas regeneradas | See scope document |
| 2 | UNE-EN ISO 10523; UNE-EN 27888; UNE-EN ISO 7027-1; ASTM 1426-15; UNE-EN 872; UNE-EN ISO 5815-1; UNE-EN ISO 6878; ISO 15705 | Aguas continentales tratadas; Aguas residuales | - |
| 3 | UNE-EN ISO 11731; LABMEDIOMIC034 | Aguas de consumo y agua sanitaria, aguas de piscinas, torres de refrigeración y condensadores evaporativos, y aguas regeneradas | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Spain
- EUROFINS ECOSUR, S.A. (Unipersonal)Lorquí · under 1 kmENACShares 1 accredited test methodISO 15705
- EUROFINS IPROMA, S.L. (Unipersonal)Castellón de la Plana · ~233 kmENACShares 1 accredited test methodISO 15705
- EUROFINS ANÁLISIS AGROSidamon · ~433 kmENACShares 1 accredited test methodISO 15705
- ADIQUIMICABarcelona · ~470 kmENACShares 1 accredited test methodISO 15705
- URIKERZamudio · ~594 kmENACShares 1 accredited test methodISO 15705
Accreditation data refreshed from the ENAC register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ENAC entry linked above.