Registers refreshed 2026-11-20.See refresh dates
United States

NATIONAL VETERINARY SERVICES

NATIONAL BIO and AGRO-DEFENSE FACILITY, 1980 Denison Ave, 66506, Manhattan, KS, United States

Visit website
A2LA 2526.09ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
3
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 3 scope lines.

A2LA certificate 2526.09 · 3 lines

LineMethodMatrixRange
1

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2526.09) 09/30/2025 Page 1 of 2 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 NATIONAL VETERINARY SERVICES LABORATORIES NATIONAL BIO AND AGRO-DEFENSE FACILITY 1980 Denison Ave Manhattan, KS 66506 Amber Gustafson Phone: 515-337-7960 CALIBRATION Valid To: June 30, 2027 Certificate Number: 2526.09 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations1, 3: I. Mechanical Parameter/Equipment Range CMC2, 4 (±) Comments Balances Up to 21 g (> 21 to 212) g (> 212 to 500) g (> 500 to 1000) g (> 1000 to 4000) g (> 4000 to 5000) g (> 5000 to 10 000) g 0.014 mg 0.59 mg 1.5 mg 3.0 mg 12 mg 14 mg 1.5 g ASTM Class 1 weights POVA – Pipettes (0.4 to 2.0) µL (> 2.0 to 10) µL (11 to 20) µL (21 to 50) µL (51 to 100) µL (101 to 300) µL (301 to 1000) µL (1001 to 5000) µL (5001 to 10 000) µL 0.025 µL 0.038 µL 0.041 µL 0.064 µL 0.086 µL 0.21 µL 0.68 µL 5.2 µL 14 µL Gravimetric calibration using balances with Class 1 weights Centrifuge – Rotation (0 to 5120) RPM (> 5120 to 20 000) RPM 2.1 RPM + 0.6R 5.5 RPM + 0.6R Tachometer ____________________________________
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2526.09) 09/30/2025 Page 2 of 2 1 This laboratory typically provides calibration service for the National Veterinary Services Laboratory and the Agricultural Research Services. 2 Calibration and Measurement Capability (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 This scope meets A2LA’s P112 Flexible Scope Policy. 4 In the statement of the CMC, R is the resolution of the unit under test.
3ISO/IEC 17025:2017; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

NATIONAL BIO and AGRO-DEFENSE FACILITY, 1980 Denison Ave, Manhattan, KS, 66506, US

39.18361, -96.57167

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.