Charles Darley and Associates
33 Campbell Street, G84 8XZ, Helensburgh, United Kingdom
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at Charles Darley and Associates?
Claim this profile to keep it accurate.
Register record
- UKASRefreshed
- 1632Active
Accredited standards
4Our reading of the UKAS scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.
ASTM C876Name not checked yet
BS EN 12504-1:2019 incorporating corrigendum November 2020 Site Sampling of concrete by drilling BS EN 14629:2007 Site Carbonation BS EN 14630:2006 Site CONCRETE - reinforced Location of reinforcement - up to 100mm cover BS 1881-204:1988 Site Corrosion potentials of uncoated reinforcing steel in concrete ASTM C876-22B Site CONCRETE BRIDGES - post-tensioned Sampling of tendon grout material Documented In-House Method STPM 6:2023; BS 1881-204; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025; ASTM C876
EN 12504-1Testing concrete in structures - Part 1: Cored specimens - Taking, examining and testing in compression
BS EN 12504-1:2019 incorporating corrigendum November 2020 Site Sampling of concrete by drilling BS EN 14629:2007 Site Carbonation BS EN 14630:2006 Site CONCRETE - reinforced Location of reinforcement - up to 100mm cover BS 1881-204:1988 Site Corrosion potentials of uncoated reinforcing steel in concrete ASTM C876-22B Site CONCRETE BRIDGES - post-tensioned Sampling of tendon grout material Documented In-House Method STPM 6:2023; BS 1881-204; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025; ASTM C876
EN 14629Name not checked yet
BS EN 12504-1:2019 incorporating corrigendum November 2020 Site Sampling of concrete by drilling BS EN 14629:2007 Site Carbonation BS EN 14630:2006 Site CONCRETE - reinforced Location of reinforcement - up to 100mm cover BS 1881-204:1988 Site Corrosion potentials of uncoated reinforcing steel in concrete ASTM C876-22B Site CONCRETE BRIDGES - post-tensioned Sampling of tendon grout material Documented In-House Method STPM 6:2023; BS 1881-204; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025; ASTM C876
EN 14630Name not checked yet
BS EN 12504-1:2019 incorporating corrigendum November 2020 Site Sampling of concrete by drilling BS EN 14629:2007 Site Carbonation BS EN 14630:2006 Site CONCRETE - reinforced Location of reinforcement - up to 100mm cover BS 1881-204:1988 Site Corrosion potentials of uncoated reinforcing steel in concrete ASTM C876-22B Site CONCRETE BRIDGES - post-tensioned Sampling of tendon grout material Documented In-House Method STPM 6:2023; BS 1881-204; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025; ASTM C876
Scope as published by UKAS
2 lines
ISO/IEC 17025
Active1632
Accredited scope, certificate 1632
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | Non-Destructive Testing | ISO/IEC 17025:2017 | Concrete | - |
| 2 | Materials Testing | BS EN 12504-1:2019 incorporating corrigendum November 2020 Site Sampling of concrete by drilling BS EN 14629:2007 Site Carbonation BS EN 14630:2006 Site CONCRETE - reinforced Location of reinforcement - up to 100mm cover BS 1881-204:1988 Site Corrosion potentials of uncoated reinforcing steel in concrete ASTM C876-22B Site CONCRETE BRIDGES - post-tensioned Sampling of tendon grout material Documented In-House Method STPM 6:2023; BS 1881-204; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; IEC 17025; ASTM C876 | Steel | to 100 mm |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United Kingdom
- Henderson Thomas AssociatesLanarkshire · ~74 kmUKASShares 2 accredited materialsConcreteSteel
- TOPBOND plc trading as Hydra Technical ServicesNorth Lincolnshire · ~378 kmUKASShares 2 accredited materialsConcreteSteel
- Structural Investigation Services Limited trading as SIS GroupIlkeston · ~403 kmUKASShares 2 accredited materialsConcreteSteel
- Kiwa Limited Trading as Kiwa CMT and Kiwa Building ProductsDerby · ~403 kmUKASShares 2 accredited materialsConcreteSteel
- Construction Testing SolutionsLeicester · ~442 kmUKASShares 2 accredited materialsConcreteSteel
Accreditation data refreshed from the UKAS register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the UKAS entry linked above.