I Pao Electronics Co.,
No. 2, Lane 159, Jinxi Road, Yangmei District, Taoyuan City, Republic of China Taiwan, Taoyuan City, Taiwan
- Scope lines
- 11
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 11 scope lines.
A2LA certificate 7723.01 · 11 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017 | Balance | 1 to 500 mg |
| 2 | - | Weight setsShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7723.01) 07/20/2026 Page 2 of 10
Parameter/Equipment
Range
CMC2(±)
Comments
Electronic weighing
instrument3
50 g to 60 kg
100 g to 75 kg
500 g to 150 kg
500 g to 300 kg
(1 to 200) kg
(>200 to 400) kg
(>400 to 600) kg
3 g(readability 1 mg)
10 g(readability 5 mg)
30 g(readability 10 mg)
20 g(readability 10 mg)
0.10 kg(readability 50 mg)
0.15 kg(readability 50 mg)
0.20 kg(readability 50 mg)
Working standards:
Weight sets
METTLER/1 mg- 1 kg/E2
METTLER/1 kg- 20 kg/E2
METTLER/1 kg- 5 kg/F1
DER HER/1 mg- 20 kg/E2
DER HER/ 20 kg/F1
Toheng/10 kg- 20 kg/F1
Weight (stainless)
1 mg
2mg
5mg
10mg
20mg
50mg
100mg
200mg
500mg
1 g
2 g
5 g
10 g
20 g
50 g
100 g
200 g
500 g
1 kg
2kg
5kg
10kg
20kg
0.003 mg
0.004 mg
0.003 mg
0.003 mg
0.004 mg
0.005 mg
0.006 mg
0.006 mg
0.004 mg
0.006 mg
0.009 mg
0.029 mg
0.06 mg
0.07 mg
0.09 mg
0.07 mg
0.10 mg
0.3 mg
0.3 mg
7 mg
0.006 g
0.007 g
0.008 g
Reference standards:
Weight sets
METTLER/1 mg – 1kg/E2
METTLER/2 kg-5 kg/ E2
METTLER/10 kg/ E2
METTLER/20 kg/E2 | See scope document |
| 3 | - | stainless steel; cast ironShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7723.01) 07/20/2026 Page 3 of 10
Parameter/Equipment
Range
CMC2 (±)
Comments
Weight (stainless steel)
1mg
2mg
5mg
10mg
20mg
50mg
100mg
200mg
500mg
1 g
2 g
5 g
10 g
20 g
50 g
60g
100 g
200g
300 g
500 g
1kg
2kg
4 kg
5kg
10kg
20kg
25 kg
30 kg
0.005 mg
0.005 mg
0.006 mg
0.007 mg
0.005 mg
0.007 mg
0.008 mg
0.007 mg
0.009 mg
0.030 mg
0.033 mg
0.043 mg
0.06 mg
0.06 mg
0.11 mg
0.18 mg
0.16 mg
0.30 mg
0.6 mg
6.1 mg
5.0 mg
8 mg
22 mg
0.035 g
0.047 g
0.066 g
0.099 g
0.16 g
Working standard:
Weight set
METTLER/ 1 mg-
20 kg/E2
Weight (cast iron)
200 g
300 g
500 g
1 kg
2 kg
4 kg
5 kg
6 kg
10 kg
20 kg
25 kg
30 kg
0.43 mg
0.7 mg
6.1 mg
5.3 mg
9 mg
22 mg
0.035 g
0.041 g
0.049 g
0.073 g
0.11 g
0.17 g
Working standards:
Weight set
METTLER/1 mg-
20 kg/E2 | See scope document |
| 4 | - | brassShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7723.01) 07/20/2026 Page 4 of 10
Parameter/Equipment
Range
CMC2 (±)
Comments
Weight (brass)
1 g
2 g
5g
10 g
20 g
50g
60 g
100 g
200g
300 g
500g
1 kg
2kg
4kg
5kg
6kg
10kg
20 kg
25 kg
30 kg
0.030 mg
0.033 mg
0.043 mg
0.07 mg
0.07 mg
0.11 mg
0.19 mg
0.18 mg
0.32 mg
0.6 mg
6.1 mg
5.1 mg
8 mg
22 mg
0.035 g
0.040 g
0.047 g
0.067 g
0.10 g
0.17 g
Working standards:
Weight set
METTLER/1 mg-
20 kg/E2
II. Electrical – DC/Low Frequency
Parameter/Range
Range
CMC2, 4(±)
Comments
DC Voltage – Measure
10 mV
100 mV
1 V
10 V
100 V
1000 V
(10 to 100) mV
>100 mV to 1000 V
86 μV/V
13 μV/V
6.5 μV/V
6.5 μV/V
9.8 μV/V
12 μV/V
86 μV/V
13 μV/V
Fluke 8508A | - |
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7723.01) 07/20/2026 Page 5 of 10
Parameter/Range
Range
CMC2, 4(±)
Comments
DC Voltage – Generate
10 mV
100 mV
1 V
10 V
100 V
1000 V
(10 to 100) mV
>100 mV to 1000 V
0.11 mV/V
11 μV/V
9.4 μV/V
6 μV/V
11 μV/V
14 μV/V
0.11 mV/V
14 μV/V
Fluke 5700A/5725A
DC Current – Measure
10 μA
100 μA
1 mA
10mA
100 mA
1 A
5 A
10 A
19 A
(10 to 200) μA
(0.2 to 2) mA
(2 to 20) mA
(20 to 200) mA
(0.2 to 2) A
(2 to 19) A
0.11 mA/A
26 μA/A
26 μA/A
26 μA/A
35 μA/A
0.12 mA/A
0.27 mA/A
0.16 mA/A
0.24 mA/A
0.13 mA/A
56 μA/A
62 μA/A
0.11 mA/A
0.17 mA/A
0.35 mA/A
Fluke 8508A
DC Current – Generate
1 μA
10μA
100 μA
1 mA
10 mA
100 mA
1 A
5 A
10 A
(10 to 200) μA
(0.2 to 2) mA
(2 to 20) mA
(20 to 200) mA
(0.2 to 2) A
(2 to 10) A
9.4 μA/A
0.99 mA/A
0.16 mA/A
72 μA/A
72 μA/A
83μA/A
0.13 mA/A
0.7 mA/A
0.54 mA/A
0.18 mA/A
98 μA/A
0.11 mA/A
0.14 mA/A
0.21 mA/A
0.7 mA/A
Fluke 5700/5725A | ||
| 6 | - | AC VoltageShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7723.01) 07/20/2026 Page 6 of 10
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Voltage – Measure
10 mV
100 mV
1 V
10 V
100 V
1000 V
(10 to 100) mV
(100 to 200) mV
>200 mv to 1000V
10 mV
100 mV
1 V
10 V
100 V
1000 V
(10 to 100) mV
(100 to 200) mV
>200 mv to 1000V
60 Hz
1 kHz
0.7 mV/V
0.13 mV/V
97 μV/V
97 μV/V
0.11 mV/V
0.13 mV/V
0.7 mV /V
0.17 mV/V
0.22 mV/V
0.54 mV/V
0.13 mV/V
74 μV/V
75 μV/V
86 μV/V
0.13 mV/V
0.54 mV/V
0.13 mV/V
0.22 mV/V
Fluke 8508A
Fluke 8508A
AC Voltage – Generate
10 mV
100 mV
1 V
10 V
100 V
1000 V
(10 to 100) mV
(100 to 200) mV
>200 mV to 1000V
10 mV
100 mV
1 V
10 V
100 V
1000 V
(10 to 100) mV
(100 to 200) mV
(200 to 1000) V
60 Hz
1 kHz
1.2 mV/V
0.23 mV/V
98 μV/V
99 μV/V
0.12 mV/V
0.13 mV/V
1.2 mV /V
0.25 mV/V
0.13 mV/V
1.2 mV/V
0.22 mV/V
98 μV/V
99 μV/V
0.12 mV/V
0.13 mV/V
1.2 mV/V
0.25 mV/V
0.13 mV/V
Fluke 5700A
Fluke 5700A | See scope document |
| 7 | - | AC CurrentShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7723.01) 07/20/2026 Page 7 of 10
Parameter/Range
Frequency
CMC2, 4(±)
Comments
AC Current – Measure
10 μA
100μA
1 mA
10 mA
100 mA
1A
5A
10A
19A
(10 to 100) μA
>0.1mA to 0.2A
(0.2 to 19) A
10μA
100μA
1 mA
10 mA
100 mA
1A
5A
10A
19A
(10 to 100) μA
>0.1mA to 0.2A
(0.2 to 19) A
60 Hz
1 kHz
4.4 mA/A
0.27 mA/A
0.27 mA/A
0.27 mA/A
0.27 mA/A
0.47 mA/A
0.71 mA/A
0.60 mA/A
0.55 mA/A
4.4 mA/A
0.47 mA/A
0.94 mA/A
1.5 mA/A
0.27 mA/A
0.27 mA/A
0.27 mA/A
0.27 mA/A
0.48 mA/A
0.72 mA/A
0.60 mA/A
0.55 mA/A
1.5 mA/A
0.44 mA/A
0.94 mA/A
Fluke 8508A
Fluke 8508A | 10 to 19 A |
| 8 | - | AC Current; ResistanceShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7723.01) 07/20/2026 Page 8 of 10
Parameter/Range
Frequency
CMC2, 4(±)
Comments
AC Current – Generate
10μA
100μA
1 mA
10 mA
100 mA
1A
5A
10A
(10 to 100) μA
>0.1mA to 0.2A
(0.2 to 10) A
10μA
100 μA
1 mA
10 mA
100 mA
1A
5A
10A
(10 to 100) μA
>0.1mA to 0.2A
(0.2 to 10) A
60 Hz
1 kHz
5.7 mA/A
0.18 mA/A
0.11 mA/A
0.11 mA/A
0.12 mA/A
0.41 mA/A
0.32 mA/A
0.31 mA/A
5.7 mA/A
0.2 mA/A
0.46 mA/A
1.2 mA/A
0.18 mA/A
0.11 mA/A
0.11 mA/A
0.12 mA/A
0.41 mA/A
0.33 mA/A
0.31 mA/A
1.2 mA/A
0.2 mA/A
0.46 mA/A
Fluke 5700A/5725A
Fluke 5700A/5725A
Parameter/Equipment
Range
CMC2, 4(±)
Comments
Resistance – Generate
0.1 mΩ
0.001 Ω
0.01 Ω
0.1 Ω
1 Ω
10 Ω
100 Ω
1 kΩ
10 kΩ
100 kΩ
1 MΩ
10 MΩ
5.6 mΩ/Ω
0.76 mΩ/Ω
0.13 mΩ/Ω
25 μΩ/Ω
59 μΩ/Ω
57 μΩ/Ω
41 μΩ/Ω
32 μΩ/Ω
15 μΩ/Ω
17 μΩ/Ω
26 μΩ/Ω
48 μΩ/Ω
Stand resistance
ZIP/P321 0.1Ω
ZIP/P310 0.01Ω
ZIP/P310 0.001Ω
Coropico/RS3.01
0.1mΩ
Fluke 5700A | See scope document |
| 9 | - | Resistance; Temperature; HumidityShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7723.01) 07/20/2026 Page 9 of 10
Parameter/Equipment
Range
CMC2, 4(±)
Comments
Resistance – Generate
(cont)
(1 to 20) Ω
(20 to 100) Ω
100 Ω to 1 kΩ
(1 to 10) kΩ
(10 to 100) kΩ
100 kΩ to 1 MΩ
(1 to 10) MΩ
(10 to 100) MΩ
0.53 mΩ/Ω
0.21 mΩ/Ω
0.13 mΩ/Ω
0.24 mΩ/Ω
0.13 mΩ/Ω
0.14 mΩ/Ω
0.25 mΩ/Ω
1.5 mΩ/Ω
TIME
ELECTRONICS
5025C-S2
Resistance – Measure
1 Ω
10 Ω
100 Ω
1kΩ
10kΩ
100kΩ
1 MΩ
10 MΩ
21 μΩ/Ω
16 μΩ/Ω
11 μΩ/Ω
11 μΩ/Ω
7.4 μΩ/Ω
8.3 μΩ/Ω
16 μΩ/Ω
31 μΩ/Ω
Fluke 8508A
III. Thermodynamics
Parameter/Range
Range
CMC2 (±)
Comments
Temperature-
Hygrometer
Digital temperature-
Hygrometer
(10 to 50) °C
(10 to 95) %RH
0.52 °C
2.3 % RH
Working standard:
Temperature-
Hygrometer
ROTRONIC/HP22-
A
Temperature & Humidity
Recorder (Display
Mode)
Digital Temperature &
Humidity Recorder
(Display Mode)
(20 to 30) °C
(30 to 85) % RH
0.5 °C
3.8 % RH
Working standard:
Temperature-
Hygrometer
ESCORT/EI-HS-D-
32-L
___________________________________________
1 This laboratory offers commercial calibration service. | See scope document |
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7723.01) 07/20/2026 Page 10 of 10
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects suc h as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMCs are expressed as eithe r a specific value that covers the full range or as a
fraction/percentage of the reading plus a fixed floor specification. | ||
| 11 | ISO/IEC 17025:2017 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.