Parker Hannifin Chomerics Test Services - Woburn, MA
84 Dragon Court, 01801, Woburn, MA, United States
- Accredited standards
- 10
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 10 standard numbers and the 10 official names we hold. When no standard matches, it searches the method text of every scope line.
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement+2 national
National versions in the same scope
AS CISPR 11national version with changes
KS C 9811national version with changes
CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission+3 national
National versions in the same scope
AS/NZS CISPR 14.1national version with changes
CNS 13783-1identical to it
KS C 9814-1national version with changes
CISPR 22Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement+1 national
National versions in the same scope
AS/NZS CISPR 22identical to it
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+3 national
National versions in the same scope
CNS 15936identical to it
KS C 9832national version with changes
VCCI-CISPR 32probably the same standard; matched by number only
FCC PART 15Radio Frequency Devices
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)+2 national
National versions in the same scope
AS/NZS 61000.3.2identical to it
KS C 9610-3-2national version with changes
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection+2 national
National versions in the same scope
AS/NZS 61000.3.3identical to it
KS C 9610-3-3national version with changes
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test+2 national
National versions in the same scope
AS/NZS 61000.4.2probably the same standard; matched by number only
KS C 9610-4-2national version with changes
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test+2 national
National versions in the same scope
AS/NZS 61000.4.3probably the same standard; matched by number only
KS C 9610-4-3national version with changes
FCC Part 15 Subpart B; ANSI C63.4:2014; FCC Part 18; MP-5:1986; IEC/CISPR 11; IEC/CISPR 14-1; IEC/CISPR 22; IEC/CISPR 32; EN 55011; EN 55014-1; EN 55022; EN 55032; KS C 9811; KS C 9814-1; KS C 9832; CNS 15936; CNS 13803; CNS 13783-1; AS CISPR 11; AS/NZS CISPR 14.1; AS/NZS CISPR 22; CAN/CSA CISPR 22; ICES 001; ICES 003; VCCI V-3; VCCI CISPR 32; VCCI 32-1; VCCI 32-2; EN 61000-3-2; IEC 61000-3-2; AS/NZS 61000.3.2; KN 61000-3-2; KS C 9610-3-2; EN 61000-3-3; IEC 61000-3-3; AS/NZS 61000.3.3; KN 61000-3-3; KS C 9610-3-3; EN 61000-4-2; IEC 61000-4-2; KN 61000-4-2; KS C 9610-4-2; AS/NZS 61000.4.2; EN 61000-4-3; IEC 61000-4-3; KN 61000-4-3; KS C 9610-4-3; AS/NZS 61000.4.3
MIL-STD-461C/462; MIL-STD-461D/E/F/G; RTCA DO-160 D/E/F/G; ANSI C63.4:2014; FCC MP-5 (February 1986)
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
4 lines
ISO/IEC 17025
Active1980.01
The scope document we hold says it was valid until 2026-06-30. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2026-03-14. Check the A2LA register for the current scope.
Accredited scope, certificate 1980.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | FCC Part 15 Subpart B; ANSI C63.4:2014; FCC Part 18; MP-5:1986; IEC/CISPR 11; IEC/CISPR 14-1; IEC/CISPR 22; IEC/CISPR 32; EN 55011; EN 55014-1; EN 55022; EN 55032; KS C 9811; KS C 9814-1; KS C 9832; CNS 15936; CNS 13803; CNS 13783-1; AS CISPR 11; AS/NZS CISPR 14.1; AS/NZS CISPR 22; CAN/CSA CISPR 22; ICES 001; ICES 003; VCCI V-3; VCCI CISPR 32; VCCI 32-1; VCCI 32-2; EN 61000-3-2; IEC 61000-3-2; AS/NZS 61000.3.2; KN 61000-3-2; KS C 9610-3-2; EN 61000-3-3; IEC 61000-3-3; AS/NZS 61000.3.3; KN 61000-3-3; KS C 9610-3-3; EN 61000-4-2; IEC 61000-4-2; KN 61000-4-2; KS C 9610-4-2; AS/NZS 61000.4.2; EN 61000-4-3; IEC 61000-4-3; KN 61000-4-3; KS C 9610-4-3; AS/NZS 61000.4.3 | - | to 18 GHz |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1980.01) 06/27/2024 Page 2 of 3
Test Technology:
Test Method(s) 1, 2:
Immunity (continued)
Electrical Fast
Transient/Burst
EN 61000-4-4 (2004+A1:2010, 2012);
IEC 61000-4-4 (2004+A1:2010, 2012);
KN 61000-4-4; KS C 9610-4-4; AS/NZS 61000.4.4
Surge Immunity EN 61000-4-5 (2006, 2014), (2016 + A1:2018);
IEC 61000-4-5 (2005, 2014);
KN 61000-4-5; KS C 9610-4-5; AS/NZS 61000.4.5
Conducted
Immunity
EN 61000-4-6 (2009, 2014); IEC 61000-4-6 (2008, 2013);
KN 61000-4-6; KS C 9610-4-6;
AS/NZS 61000.4.6
Power Frequency
Magnetic Field
Immunity
EN 61000-4-8 (2010); IEC 61000-4-8 (2009);
KN 61000-4-8; KS C 9610-4-8;
AS/NZS 61000.4.8
Voltage Dips, Short
Interruptions, and
Line Voltage
Variations
EN 61000-4-11 (2004, A1:2018, 2020); IEC 61000-4-11 (2004);
KN 61000-4-11; KS C 9610-4-11;
AS/NZS 61000.4.11
Close Proximity
Radiated Field
Immunity
EN/IEC 61000-4-39 (2017)
Generic Standards EN/IEC 61000-6-1; KS C 9610-6-1; EN/IEC 61000-6-2; KS C 9610-6-2;
EN/IEC 61000-6-3; KS C 9610-6-3; EN/IEC 61000-6-4; KS C 9610-6-4;
AS/NZS 61000.6.1; AS/NZS 61000.6.2;
AS/NZS 61000.6.3; AS/NZS 61000.6.4
Product Standards IEC/CISPR 14-2; EN/IEC 55014-2;
IEC/CISPR 24; EN/IEC 55024;
ETSI EN 302 340 (Section 6.2);
ETSI EN 301 843-1; ETSI EN 301 843-6;
ETSI EN 300 386; ETSI EN 301 489-1; ETSI EN 301 489-17;
EN 55103-1; EN 55103-2;
KS C 9814-2; KN 24; CISPR 25; KS C 9835; EN55035; CISPR 35;
EN/IEC 60945 (Sections 9, 10, and 11.2);
EN/IEC 61326-1;
EN/IEC 61326-2-1; EN/IEC 61326-2-2; EN/IEC 61326-2-3;
EN/IEC 61326-2-4; EN/IEC 61326-2-5; EN/IEC 61326-2-6;
AAMI/EN/IEC 60601-1-2; KS C IEC 60601-1-2;
AAMI/EN/IEC 60601-2-2; EN/IEC 60601-2-4;
EN/IEC 60601-2-18; EN/IEC 60601-2-23;
EN/IEC 60601-2-24; AAMI/EN/IEC 60601-2-25;
EN/IEC 60601-2-26; AAMI/EN/IEC 60601-2-27;
EN/IEC 60601-2-34; EN/IEC 60601-2-37;
AAMI/EN/IEC 60601-2-47;
EN/IEC 60601-2-49; EN 60601-1-10;
EN 60730-1; EN 60730-2-9;
EN 60601-1-12 (Section 11 only);
EN 63044-5-1; EN 63044-5-2 | ||
| 3 | MIL-STD-461C/462; MIL-STD-461D/E/F/G; RTCA DO-160 D/E/F/G; ANSI C63.4:2014; FCC MP-5 (February 1986) | - | to 18000 MHz |
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
PARKER HANNIFIN CHOMERICS TEST SERVICES –
WOBURN, MA
Woburn, MA
for technical competence in the field of
Electrical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 27th day of June 2024.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 1980.01
Valid to June 30, 2026 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Intertek Testing Services NABoxborough, MA · ~30 kmA2LAShares 1 accredited test methodANSI C63.4:2014
- TUV Rheinland of North AmericaBoxborough, MA · ~30 kmA2LAShares 1 accredited test methodANSI C63.4:2014
- Eurofins Electrical and Electronic Testing NALittleton, MA · ~30 kmA2LAShares 1 accredited test methodANSI C63.4:2014
- Compliance Management Group (CMG)Marlboro, MA · ~30 kmA2LAShares 1 accredited test methodANSI C63.4:2014
- Core Compliance Testing ServicesHudson, NH · ~40 kmA2LAShares 1 accredited test methodANSI C63.4:2014
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.