National Centers for Animal Health
NATIONAL CENTERS FOR ANIMAL HEALTH, 1920 Dayton Avenue, 50010, Ames, IA, United States
Visit website- Scope lines
- 4
- A2LA certificate
- 1
- Sites in our directory
- 2
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 4 scope lines.
A2LA certificate 2526.03 · 4 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017 | - | to 5000 g |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2526.03) Revised 04/21/2026 Page 2 of 3
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
POVA – Pipettes
(0.4 to 2.0) µL
(> 2.0 to 10) µL
(11 to 20) µL
(21 to 50) µL
(51 to 100) µL
(101 to 300) µL
(301 to 1000) µL
(1001 to 5000) µL
(5001 to 10 000) µL
0.025 µL
0.038 µL
0.041 µL
0.064 µL
0.086 µL
0.21 µL
0.68 µL
5.2 µL
14 µL
Gravimetric
calibration using
balances with Class 1
weights
Centrifuge – Rotation
(0 to 5120) RPM
(> 5120 to 20 000) RPM
2.1 RPM + 0.6R
5.5 RPM + 0.6R
Tachometer
III. Thermodynamics
Parameter/Equipment
Range
CMC2, 4, 5 (±)
Comments
Temperature – Measuring
Equipment
-80 °C
(> -80 to 0) °C
(> 0 to 156) °C
0.071 °C + 0.6R
0.035 °C + 0.6R
0.049 °C + 0.6R
Fluke 1524, PRT,
baths
Temperature – Measure
(-80 to 0) °C
(> 0 to 156) °C
(0 to 100) °C
(4 to 37) °C
(> 37 to 99) °C
0.032 °C
0.045 °C
0.65 °C
0.056 °C
0.075 °C
Fluke 1524 & PRT
Fluke readout & T-
Type thermocouple
Thermistor
Autoclaves –
Temperature
Uniformity &
Temperature Accuracy
(100 to 140) °C
0.11 °C + 0.6R
Data loggers
1 This laboratory typically provides calibration service for the National Veterinary Services Laboratory and
the Center for Veterinary Biologics Laboratory. | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2526.03) Revised 04/21/2026 Page 3 of 3
2 Calibration and Measurement Capability (CMC) is the smallest uncertainty of measurement that a
laboratory can achieve within its scope of accreditation when performing more or less routine calibrations
of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded
uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of
k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be
greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 This scope meets A2LA’s P112 Flexible Scope Policy.
4 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
5 In the statement of the CMC, R is the resolution of the unit under test. | ||
| 4 | ISO/IEC 17025:2017 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
NATIONAL CENTERS FOR ANIMAL HEALTH, 1920 Dayton Avenue, Ames, IA, 50010, US
42.02676, -93.61704
Open in MapsOther Locations
1 other site in this organization
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.