FindTestingLabs
Registers refreshed 2026-09-25.See refresh dates
United States

Element Materials Technology Seattle

2200 222nd Street SE, 98021, Bothell, WA, United States

A2LA|2582.03ISO/IEC 17025Register refreshed 2026-09-25
Certificates
1
Scope items
4
Standards
13
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at Element Materials Technology Seattle?

Claim this profile to keep it accurate.

Register record

A2LARefreshed
2582.03Active

Accredited standards

13

Our reading of the A2LA scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.

ASTM

ASTM B117Standard Practice for Operating Salt Spray (Fog) Apparatus
As written on the certificate · Line 1 (A2LA 2582.03)

ASTM G85; ASTM B117; ASTM D1735; ASTM D2247; DIN 50021-SS; IEC 60945, Section 8.12; RTCA/DO-160 D, E, F, G, Section 14 (Category S & T); MIL-STD-202, Method 101E; MIL-STD-810 G, H, Method 509; MIL-DTL-5541F; SAE J1810, Section 5.7; GMW 3172, Section 9.4.8; JDQ 53.3, Section 8.1, Level 3; ISO 4892-2; ASTM G26-96; ASTM G155; ASTM D2565; IEC 60529, Section 13; MIL-STD-202, Method 110A; MIL-STD-810 G, H, Method 510, Procedure I; RTCA/DO-160, Section 12.4 (Category D); GMW 3172, Section 9.5.1; RTCA DO-160 D, E, F, G, Section 12.4; MIL-STD-810 G, H, Method 510, Procedure II

ASTM D1735Name not checked yet
As written on the certificate · Line 1 (A2LA 2582.03)

ASTM G85; ASTM B117; ASTM D1735; ASTM D2247; DIN 50021-SS; IEC 60945, Section 8.12; RTCA/DO-160 D, E, F, G, Section 14 (Category S & T); MIL-STD-202, Method 101E; MIL-STD-810 G, H, Method 509; MIL-DTL-5541F; SAE J1810, Section 5.7; GMW 3172, Section 9.4.8; JDQ 53.3, Section 8.1, Level 3; ISO 4892-2; ASTM G26-96; ASTM G155; ASTM D2565; IEC 60529, Section 13; MIL-STD-202, Method 110A; MIL-STD-810 G, H, Method 510, Procedure I; RTCA/DO-160, Section 12.4 (Category D); GMW 3172, Section 9.5.1; RTCA DO-160 D, E, F, G, Section 12.4; MIL-STD-810 G, H, Method 510, Procedure II

ASTM D2247Name not checked yet
As written on the certificate · Line 1 (A2LA 2582.03)

ASTM G85; ASTM B117; ASTM D1735; ASTM D2247; DIN 50021-SS; IEC 60945, Section 8.12; RTCA/DO-160 D, E, F, G, Section 14 (Category S & T); MIL-STD-202, Method 101E; MIL-STD-810 G, H, Method 509; MIL-DTL-5541F; SAE J1810, Section 5.7; GMW 3172, Section 9.4.8; JDQ 53.3, Section 8.1, Level 3; ISO 4892-2; ASTM G26-96; ASTM G155; ASTM D2565; IEC 60529, Section 13; MIL-STD-202, Method 110A; MIL-STD-810 G, H, Method 510, Procedure I; RTCA/DO-160, Section 12.4 (Category D); GMW 3172, Section 9.5.1; RTCA DO-160 D, E, F, G, Section 12.4; MIL-STD-810 G, H, Method 510, Procedure II

ASTM D2565Name not checked yet
As written on the certificate · Line 1 (A2LA 2582.03)

ASTM G85; ASTM B117; ASTM D1735; ASTM D2247; DIN 50021-SS; IEC 60945, Section 8.12; RTCA/DO-160 D, E, F, G, Section 14 (Category S & T); MIL-STD-202, Method 101E; MIL-STD-810 G, H, Method 509; MIL-DTL-5541F; SAE J1810, Section 5.7; GMW 3172, Section 9.4.8; JDQ 53.3, Section 8.1, Level 3; ISO 4892-2; ASTM G26-96; ASTM G155; ASTM D2565; IEC 60529, Section 13; MIL-STD-202, Method 110A; MIL-STD-810 G, H, Method 510, Procedure I; RTCA/DO-160, Section 12.4 (Category D); GMW 3172, Section 9.5.1; RTCA DO-160 D, E, F, G, Section 12.4; MIL-STD-810 G, H, Method 510, Procedure II

ASTM D4169Name not checked yet
As written on the certificate · Line 3 (A2LA 2582.03)

MIL-STD-810 G; MIL-STD-810 H; RCTA DO-160 D; RCTA DO-160 E; RCTA DO-160 F; RCTA DO-160 G; IEC 60945; SAE J1810; IEC 60529:2013; DIN 40050; ISO 20653; UN38.3; GMW 3172; GMW 8287; Qualmark 933-0326; ASTM D4169; Element VC 202

ASTM G26Name not checked yet
As written on the certificate · Line 1 (A2LA 2582.03)

ASTM G85; ASTM B117; ASTM D1735; ASTM D2247; DIN 50021-SS; IEC 60945, Section 8.12; RTCA/DO-160 D, E, F, G, Section 14 (Category S & T); MIL-STD-202, Method 101E; MIL-STD-810 G, H, Method 509; MIL-DTL-5541F; SAE J1810, Section 5.7; GMW 3172, Section 9.4.8; JDQ 53.3, Section 8.1, Level 3; ISO 4892-2; ASTM G26-96; ASTM G155; ASTM D2565; IEC 60529, Section 13; MIL-STD-202, Method 110A; MIL-STD-810 G, H, Method 510, Procedure I; RTCA/DO-160, Section 12.4 (Category D); GMW 3172, Section 9.5.1; RTCA DO-160 D, E, F, G, Section 12.4; MIL-STD-810 G, H, Method 510, Procedure II

ASTM G85Name not checked yet
As written on the certificate · Line 1 (A2LA 2582.03)

ASTM G85; ASTM B117; ASTM D1735; ASTM D2247; DIN 50021-SS; IEC 60945, Section 8.12; RTCA/DO-160 D, E, F, G, Section 14 (Category S & T); MIL-STD-202, Method 101E; MIL-STD-810 G, H, Method 509; MIL-DTL-5541F; SAE J1810, Section 5.7; GMW 3172, Section 9.4.8; JDQ 53.3, Section 8.1, Level 3; ISO 4892-2; ASTM G26-96; ASTM G155; ASTM D2565; IEC 60529, Section 13; MIL-STD-202, Method 110A; MIL-STD-810 G, H, Method 510, Procedure I; RTCA/DO-160, Section 12.4 (Category D); GMW 3172, Section 9.5.1; RTCA DO-160 D, E, F, G, Section 12.4; MIL-STD-810 G, H, Method 510, Procedure II

ASTM G155Name not checked yet
As written on the certificate · Line 1 (A2LA 2582.03)

ASTM G85; ASTM B117; ASTM D1735; ASTM D2247; DIN 50021-SS; IEC 60945, Section 8.12; RTCA/DO-160 D, E, F, G, Section 14 (Category S & T); MIL-STD-202, Method 101E; MIL-STD-810 G, H, Method 509; MIL-DTL-5541F; SAE J1810, Section 5.7; GMW 3172, Section 9.4.8; JDQ 53.3, Section 8.1, Level 3; ISO 4892-2; ASTM G26-96; ASTM G155; ASTM D2565; IEC 60529, Section 13; MIL-STD-202, Method 110A; MIL-STD-810 G, H, Method 510, Procedure I; RTCA/DO-160, Section 12.4 (Category D); GMW 3172, Section 9.5.1; RTCA DO-160 D, E, F, G, Section 12.4; MIL-STD-810 G, H, Method 510, Procedure II

Other standards

IEC 60529Degrees of protection provided by enclosures (IP Code)
As written on the certificate · Line 1 (A2LA 2582.03)

ASTM G85; ASTM B117; ASTM D1735; ASTM D2247; DIN 50021-SS; IEC 60945, Section 8.12; RTCA/DO-160 D, E, F, G, Section 14 (Category S & T); MIL-STD-202, Method 101E; MIL-STD-810 G, H, Method 509; MIL-DTL-5541F; SAE J1810, Section 5.7; GMW 3172, Section 9.4.8; JDQ 53.3, Section 8.1, Level 3; ISO 4892-2; ASTM G26-96; ASTM G155; ASTM D2565; IEC 60529, Section 13; MIL-STD-202, Method 110A; MIL-STD-810 G, H, Method 510, Procedure I; RTCA/DO-160, Section 12.4 (Category D); GMW 3172, Section 9.5.1; RTCA DO-160 D, E, F, G, Section 12.4; MIL-STD-810 G, H, Method 510, Procedure II

As written on the certificate · Line 3 (A2LA 2582.03)

MIL-STD-810 G; MIL-STD-810 H; RCTA DO-160 D; RCTA DO-160 E; RCTA DO-160 F; RCTA DO-160 G; IEC 60945; SAE J1810; IEC 60529:2013; DIN 40050; ISO 20653; UN38.3; GMW 3172; GMW 8287; Qualmark 933-0326; ASTM D4169; Element VC 202

IEC 60945Maritime navigation and radiocommunication equipment and systems - General requirements - Methods of testing and required test results
As written on the certificate · Line 1 (A2LA 2582.03)

ASTM G85; ASTM B117; ASTM D1735; ASTM D2247; DIN 50021-SS; IEC 60945, Section 8.12; RTCA/DO-160 D, E, F, G, Section 14 (Category S & T); MIL-STD-202, Method 101E; MIL-STD-810 G, H, Method 509; MIL-DTL-5541F; SAE J1810, Section 5.7; GMW 3172, Section 9.4.8; JDQ 53.3, Section 8.1, Level 3; ISO 4892-2; ASTM G26-96; ASTM G155; ASTM D2565; IEC 60529, Section 13; MIL-STD-202, Method 110A; MIL-STD-810 G, H, Method 510, Procedure I; RTCA/DO-160, Section 12.4 (Category D); GMW 3172, Section 9.5.1; RTCA DO-160 D, E, F, G, Section 12.4; MIL-STD-810 G, H, Method 510, Procedure II

As written on the certificate · Line 2 (A2LA 2582.03)

IEC 60945; MIL-STD-202; MIL-STD-810 G; MIL-STD-810 H; RTCA/DO-160 D; RTCA/DO-160 E; RTCA/DO-160 F; RTCA/DO-160 G; SAE J1810; GMW 3172; UN38.3

As written on the certificate · Line 3 (A2LA 2582.03)

MIL-STD-810 G; MIL-STD-810 H; RCTA DO-160 D; RCTA DO-160 E; RCTA DO-160 F; RCTA DO-160 G; IEC 60945; SAE J1810; IEC 60529:2013; DIN 40050; ISO 20653; UN38.3; GMW 3172; GMW 8287; Qualmark 933-0326; ASTM D4169; Element VC 202

ISO 4892-2Plastics - Methods of exposure to laboratory light sources - Part 2: Xenon-arc lamps
As written on the certificate · Line 1 (A2LA 2582.03)

ASTM G85; ASTM B117; ASTM D1735; ASTM D2247; DIN 50021-SS; IEC 60945, Section 8.12; RTCA/DO-160 D, E, F, G, Section 14 (Category S & T); MIL-STD-202, Method 101E; MIL-STD-810 G, H, Method 509; MIL-DTL-5541F; SAE J1810, Section 5.7; GMW 3172, Section 9.4.8; JDQ 53.3, Section 8.1, Level 3; ISO 4892-2; ASTM G26-96; ASTM G155; ASTM D2565; IEC 60529, Section 13; MIL-STD-202, Method 110A; MIL-STD-810 G, H, Method 510, Procedure I; RTCA/DO-160, Section 12.4 (Category D); GMW 3172, Section 9.5.1; RTCA DO-160 D, E, F, G, Section 12.4; MIL-STD-810 G, H, Method 510, Procedure II

ISO 20653Road vehicles - Degrees of protection (IP code) - Protection of electrical equipment against foreign objects, water and access
As written on the certificate · Line 3 (A2LA 2582.03)

MIL-STD-810 G; MIL-STD-810 H; RCTA DO-160 D; RCTA DO-160 E; RCTA DO-160 F; RCTA DO-160 G; IEC 60945; SAE J1810; IEC 60529:2013; DIN 40050; ISO 20653; UN38.3; GMW 3172; GMW 8287; Qualmark 933-0326; ASTM D4169; Element VC 202

UN 38.3Lithium metal and lithium ion batteries
As written on the certificate · Line 2 (A2LA 2582.03)

IEC 60945; MIL-STD-202; MIL-STD-810 G; MIL-STD-810 H; RTCA/DO-160 D; RTCA/DO-160 E; RTCA/DO-160 F; RTCA/DO-160 G; SAE J1810; GMW 3172; UN38.3

As written on the certificate · Line 3 (A2LA 2582.03)

MIL-STD-810 G; MIL-STD-810 H; RCTA DO-160 D; RCTA DO-160 E; RCTA DO-160 F; RCTA DO-160 G; IEC 60945; SAE J1810; IEC 60529:2013; DIN 40050; ISO 20653; UN38.3; GMW 3172; GMW 8287; Qualmark 933-0326; ASTM D4169; Element VC 202

Scope as published by A2LA

4 lines
A2LA

ISO/IEC 17025

Active

2582.03

The scope document we hold says it is valid until 2027-01-31.

View scope

Accredited scope, certificate 2582.03

LineDisciplineMethodMatrixRange
1mechanicalASTM G85; ASTM B117; ASTM D1735; ASTM D2247; DIN 50021-SS; IEC 60945, Section 8.12; RTCA/DO-160 D, E, F, G, Section 14 (Category S & T); MIL-STD-202, Method 101E; MIL-STD-810 G, H, Method 509; MIL-DTL-5541F; SAE J1810, Section 5.7; GMW 3172, Section 9.4.8; JDQ 53.3, Section 8.1, Level 3; ISO 4892-2; ASTM G26-96; ASTM G155; ASTM D2565; IEC 60529, Section 13; MIL-STD-202, Method 110A; MIL-STD-810 G, H, Method 510, Procedure I; RTCA/DO-160, Section 12.4 (Category D); GMW 3172, Section 9.5.1; RTCA DO-160 D, E, F, G, Section 12.4; MIL-STD-810 G, H, Method 510, Procedure II--
2mechanicalIEC 60945; MIL-STD-202; MIL-STD-810 G; MIL-STD-810 H; RTCA/DO-160 D; RTCA/DO-160 E; RTCA/DO-160 F; RTCA/DO-160 G; SAE J1810; GMW 3172; UN38.3--100 to 60000 °C; %RH; lbf; Hz; Gs; feet; ms
3mechanicalMIL-STD-810 G; MIL-STD-810 H; RCTA DO-160 D; RCTA DO-160 E; RCTA DO-160 F; RCTA DO-160 G; IEC 60945; SAE J1810; IEC 60529:2013; DIN 40050; ISO 20653; UN38.3; GMW 3172; GMW 8287; Qualmark 933-0326; ASTM D4169; Element VC 202-to 25 G’s
4mechanical
For the types of tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation. Accredited Laboratory A2LA has accredited ELEMENT MATERIALS TECHNOLOGY SEATTLE Bothell, WA for technical competence in the field of Mechanical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 26th day of November 2024. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 2582.03 Valid to January 31, 2027