Registers refreshed 2026-11-08.See refresh dates
United States

Optronic Laboratories, LLC

4632 36TH STREET, 32811, ORLANDO, FL, United States

Visit website
A2LA 6064.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
3
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 3 scope lines.

A2LA certificate 6064.01 · 3 lines

LineMethodMatrixRange
1--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6064.01) 06/17/2025 Page 1 of 2 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 OPTRONIC LABORATORIES, LLC. 4632 36 th St. Suite 300 Orlando, FL 32811 Nicole Cooper, Operations Mgr. Phone: 407 785 6019 CALIBRATION Valid To: June 30, 2027 Certificate Number: 6064.01 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations1, 4: I. Optical Quantities Parameter/Equipment Range CMC2, 3 (±) Comments Total Luminous Flux – Measurement of Incandescent Lamps 45 W 75 W 200 W (550 to 790) lm (1135 to 1270) lm (4440 to 5850) lm 1.2 % Comparison to spectral radiance flux lamp Total Spectral Radiant Flux – Measurement of 45 W, 75 W, & 200 W Incandescent Lamps Up to 30 mW/nm (300 to 320) nm (330 to 350) nm (360 to 410) nm (420 to 460) nm (470 to 580) nm (590 to 820) nm (830 to 930) nm (940 to 1040) nm (1050 to 1100) nm 3.5 % 3.0 % 2.5 % 2.0 % 1.5 % 1.3 % 1.5 % 2.0 % 2.5 % Comparison to spectral radiance flux lamp. Reported in W/nm within wavelength range.
to 30 mW/nm
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6064.01) 06/17/2025 Page 2 of 2 Parameter/Equipment Range CMC2, 3 (±) Comments Spectral Irradiance – Measurement of 45 W, 200 W, & 1000 W Incandescent Lamps. Up to 25 µW/(cm2 nm) 250 nm 260 nm (270 to 280) nm (290 to 300) nm (310 to 320) nm (330 to 350) nm (360 to 390) nm (400 to 450) nm (500 to 600) nm (654.6 to 1100) nm 6.5 % 6.0 % 5.0 % 4.2 % 3.5 % 3.1 % 2.5 % 2.4 % 1.7 % 1.3 % Comparison to NIST FEL 1000 W lamp. Reported in W/(cm² nm) within wavelength range. Integrated Spectral Irradiance Response – Measurement of Accentor Radiometer (340 to 350) nm (0.080 to 0.104) V 4.5 % Comparison to Xenon transfer lamp ____________________________________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavio r of the customer’s device and to influences from the circumstances of the specific calibration. 3 In the statement of CMC, percentages are defined as percent of reading, unless otherwise noted. 4 This scope meets A2LA’s P112 Flexible Scope Policy.
3

Extracted from the scope document; tables may not line up. View scope for the original.

For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation. Accredited Laboratory A2LA has accredited OPTRONIC LABORATORIES, LLC Orlando, FL for technical competence in the field of Calibration This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories . This laboratory also meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 17th day of June 2025. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 6064.01 Valid to June 30th, 2027

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

4632 36TH STREET, ORLANDO, FL, 32811, US

28.54212, -81.37905

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.