Yokogawa Corporation of America

2 Dart Road, 30265, Newnan, GA, United States

Visit website
A2LA 3474.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
10
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 10 scope lines.

A2LA certificate 3474.01 · 10 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-to 1050 V
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3474.01) 01/05/2026 Page 2 of 9 Parameter/Equipment Range CMC2, 3, 4 (±) Comments DC Current – Measure Up to 199.990 000 µA (>0.199 99 to 1.999 900 00) mA (>1.9999 to 19.999 000 0) mA (>19.999 to 199.990 000) mA (>0.199 99 to 1.999 900 00) A (1.9999 to 20) A 14 µA/A + 1.5 µA 18 µA/A + 1.5 µA 48 µA/A + 1.5 µA 88 µA/A + 3.6 µA 340 µA/A + 32 µA 530 µA/A + 0.46 mA Fluke 8508A Resistance – Generate Up to 11 Ω (11 to 33) Ω (33 to 110) Ω (110 to 330) Ω (0.33 to 1.1) kΩ (1.1 to 3.3) kΩ (3.3 to 11) kΩ (11 to 33) kΩ (33 to 110) kΩ (110 to 330) kΩ (0.33 to 1.1) MΩ (1.1 to 3.3) MΩ (3.3 to 11) MΩ (11 to 33) MΩ (33 to 110) MΩ (110 to 330) MΩ (330 to 1100) MΩ 31 μΩ/Ω + 7.6 mΩ 23 μΩ/Ω + 11 mΩ 22 μΩ/Ω + 11 mΩ 22 μΩ/Ω + 15 mΩ 22 μΩ/Ω + 15 mΩ 22 μΩ/Ω + 150 mΩ 22 μΩ/Ω + 76 mΩ 22 μΩ/Ω + 760 mΩ 22 μΩ/Ω + 760 mΩ 25 μΩ/Ω + 7.6 Ω 25 μΩ/Ω + 7.6 Ω 46 μΩ/Ω + 120 Ω 0.010 % + 190 Ω 0.020 % + 1.9 kΩ 0.039 % + 2.2 kΩ 0.23 % + 75 kΩ 1.2 % + 380 kΩ Fluke 5522A Resistance – Measure Up to 2 Ω Up to 20 Ω Up to 200 Ω Up to 2 kΩ Up to 20 kΩ Up to 200 kΩ Up to 2 MΩ Up to 20 MΩ Up to 200 MΩ Up to 2 GΩ 0.51 % + 54 µΩ 7.5 µΩ /Ω + 5.9 µΩ 7.6 µΩ /Ω + 0.15 mΩ 7.6 µΩ /Ω + 1.5 mΩ 7.6 µΩ /Ω + 15 mΩ 43 µΩ /Ω + 0.15 Ω 9.6 µΩ /Ω + 1.1 Ω 22 µΩ /Ω + 91 Ω 0.013 % + 9.1 kΩ 0.14 % + 910 kΩ Fluke 8508A Oscilloscopes – Level Sine Amp 50 Ω Level Sine Flatness Relative to 50 kHz Reference 4.4 mV to 5.560 V p-p 0.1 Hz to 550 MHz 550 MHz to 1.16 GHz (1.16 to 2.5) GHz (2.5 to 3.2) GHz 2.1 % 5.0 % flatness 6.0 % flatness 5.5 % flatness 5.5 % flatness Fluke 9500B 0.2 Hz to 550 MHz 5V 3V 2V
to 20 A
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3474.01) 01/05/2026 Page 3 of 9 Parameter/Equipment Range CMC2, 3, 4 (±) Comments Oscilloscopes – (cont) Square Wave Amp DC Signal Level Edge Transition Time Time Marker Output Frequency 2 mV to 200 V p-p 2 mV to 5 Vp-p ±1 mV to ±200 V ±1 mV to ±5 V 10 Hz to 2 MHz (0.5 to 10) ns (10 to 40) Hz 40 Hz to 11.999 kHz 12 kHz to 10 MHz 0.18 % 0.18 % 0.086 % 0.097 % 210 ps 0.20 % 73 µHz/Hz + 240 µHz 53 µHz/Hz + 47 mHz 12 µHz/Hz + 340 mHz Fluke 9500B Into 1 MΩ load Into 50 Ω load (10 Hz) Into 1 MΩ load Into 50 Ω load Fluke 9500B Electrical Calibration of Thermocouple Indicating Systems3– Type E Type J Type K Type T (250 to 1000) °C (210 to 1200) °C (200 to 1372) °C (250 to 400) °C 0.45 °C 0.27 °C 0.37 °C 0.56 °C Fluke 5522A DC Power – Generate 33 mV to 1020 V (0.33 to 329.99) mA (0.33 to 2.9999) A (3 to 20.5) A 0.18 mW/W + 1.8 µW 0.17 mW/W + 25 µW 0.54 mW/W + 85 µW Fluke 5522A Parameter/Range Frequency CMC2, 3 (±) Comments AC Voltage – Generate (1.0 to 33) mV (10 to 45) Hz 45 Hz to 10 kHz 0.061 % + 4.6 µV 0.012 % + 4.6 µV Fluke 5522A
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3474.01) 01/05/2026 Page 4 of 9 Parameter/Range Frequency CMC2, 3 (±) Comments AC Voltage – Generate (cont) (1.0 to 33) mV (33 to 330) mV (0.33 to 3.3) V (3.3 to 33) V (33 to 330) V (330 to 1020) V (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 0.015 % + 4.6 µV 0.077 % + 4.6 µV 0.27 % + 9.1 µV 0.023 % + 38 µV 0.011 % + 6.1 µV 0.012 % + 6.1 µV 0.027 % + 6.1 µV 0.061 % + 24 µV 0.023 % + 38 µV 0.015 % + 46 µV 0.015 % + 46 µV 0.023 % + 38 µV 0.054 % + 95 µV 0.18 % + 0.46 mV 0.023 % + 0.50 mV 0.012 % + 0.46 mV 0.018 % + 0.46 mV 0.027 % + 0.46 mV 0.069 % + 1.2 mV 0.015 % + 1.5 mV 0.015 % + 4.6 mV 0.019 % + 4.6 mV 0.023 % + 4.6 mV 0.15 % + 38 mV 0.023 % + 7.9 µV 0.019 % + 7.9 µV 0.023 % + 7.8 µV Fluke 5522A AC Voltage – Measure Up to 199.990 000 mV (10 to 40) Hz (40 to 100) Hz 100 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz 0.012 % + 5.3 µV 0.010 % + 3.9 µV 0.010 % + 1.9 µV 0.013 % + 3.8 µV 0.030 % + 7.6 µV 0.066 % + 18 µV Fluke 8508A
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3474.01) 01/05/2026 Page 5 of 9 Parameter/Range Frequency CMC2, 3 (±) Comments AC Voltage – Measure (cont) (>0.1999 to 1.999 900 00) V (>1.9999 to 19.999 000 0) V (>19.999 to 199.990 000) V (>199.99 to 1050) V (10 to 40) Hz (40 to 100) Hz 100 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (10 to 40) Hz (40 to 100) Hz 100 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (40 to 100) Hz 100 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz 40 Hz to 5 kHz 0.010 % + 19 µV 0.0084 % + 19 µV 0.0069 % + 19 µV 0.010 % + 19 µV 0.020 % + 38 µV 0.050 % + 180 µV 0.23 % + 1.8 mV 0.77 % + 18 mV 0.010 % + 0.19 mV 84 µV/V + 0.19 mV 68 µV/V + 0.19 mV 0.010 % + 0.19 mV 0.020 % + 0.38 mV 0.05 % + 1.8 mV 0.0084 % + 1.9 mV 0.041 % + 1.9 mV 0.010 % + 2.0 mV 0.020 % + 3.9 mV 0.05 % + 18 mV 0.011 % + 20 mV Fluke 8508A AC Current – Generate (29 to 329.9999) µA (0.33 to 3.299 999) mA (3.3 to 32.999 99) mA (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz 0.019 mA/A + 0.076 µA 0.012 mA/A + 0.076 µA 9.6 µA/A + 0.076 µA 0.023 mA/A + 0.11 µA 0.061 mA/A + 0.15 µA 0.12 mA/A + 0.3 µA 20 µA/A + 0.16 µA 11 µA/A + 0.11 µA 8.3 µA/A + 0.11 µA 16 µA/A + 0.15 µA 38 µA/A + 0.23 µA 77 µA/A + 0.46 µA 31 µA/A + 1.6 µA 8.4 µA/A + 1.5 µA 5.2 µA/A + 1.5 µA 7.5 µA/A + 0.15 µA 16 µA/A + 2.3 µA 31 µA/A + 3.0 µA Fluke 5522A
6--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3474.01) 01/05/2026 Page 6 of 9 Parameter/Range Frequency CMC2, 3 (±) Comments AC Current – Generate (cont) (33 to 329.9999) mA (0.33 to 1.1) A (1.1 to 3) A (3 to 11) A (11 to 20.5) A (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (45 to 100) Hz 100 Hz to 1 kHz (1 to 5) kHz (45 to 100) Hz 100 Hz to 1 kHz (1 to 5) kHz 30 µA/A + 16 µA 8.6 µA/A + 15 µA 1.6 µA/A + 15 µA 8.2 µA/A + 38 µA 16 µA/A + 76 µA 31 µA/A + 150 µA 27 µA/A + 77 µA 3.8 µA/A + 76 µA 46 µA/A + 760 µA 46 µA/A + 760 µA 11 µA/A + 0.083 mA 4.6 µA/A + 0.076 mA 46 µA/A + 0.76 mA 190 µA/A + 3.8 mA 4.7 µA/A + 1.5 mA 7.8 µA/A + 1.5 mA 230 µA/A + 1.5 mA 10 µA/A + 3.8 mA 12 µA/A + 3.8 mA 230 µA/A + 3.8 mA Fluke 5522A AC Current – Measure Up to 199.9900 µA (>0.199 99 to 1.999 900) mA (>1.9999 to 19.999 00) mA (>19.999 to 199.9900) mA (>0.1999 to 1.999 900) A (>1.999 900 to 20) A 10 Hz to 10 kHz (10 to 30) kHz 10 Hz to 10 kHz (10 to 30) kHz 10 Hz to 10 kHz (10 to 30) kHz 10 Hz to 10kHz (10 to 30) kHz 10 Hz to 2 kHz (2 to 10) kHz 10 Hz to 2 kHz (2 to 10) kHz 0.048 % + 18 µA 0.061 % + 18 µA 0.028 % + 18 µA 0.061 % + 18 µA 0.028 % + 18 µA 0.061 % + 18 µA 0.028 % + 18 µA 0.057 % + 18 µA 0.066 % + 19 µA 0.23 % + 19 µA 0.070 % + 66 µA 0.19 % + 63 µA Fluke 8508A
to 0.00019999 A
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3474.01) 01/05/2026 Page 7 of 9 Parameter/Range Frequency CMC2, 3, 4 (±) Comments Capacitance – Generate (0.19 to 1.0999) nF (1.10 to 3.2999) nF (3.3 to 329.999) nF (.33 to 1.099 99) µF (1.1 to 3.299 99) µF (3.3 to 10.9999) µF (11 to 32.9999) µF (33 to 109.999) µF (110 to 329.999) µF (0.33 to 1.099 99) mF (1.1 to 3.2999) mF (3.3 to 10.9999) mF (11 to 32.9999) mF 10 Hz to 10 kHz (10 to 3000) Hz (10 to 1000) Hz (10 to 600) Hz (10 to 300) Hz (10 to 150) Hz (10 to 120) Hz (10 to 80) Hz (0 to 50) Hz (0 to 20) Hz (0 to 6) Hz (0 to 2) Hz (0 to 0.6) Hz 1.1 % 0.55 % 0.23 % 0.23 % 0.23 % 0.24 % 0.32 % 0.41 % 0.35 % 0.35 % 0.35 % 0.35 % 0.64 % Fluke 5522A Phase – Generate (0 to ± 179.99)° 45 Hz to 10 kHz 0.12° Fluke 5522A Parameter/Equipment Range CMC2, 3(±) Comments AC Power – Generate, PF = 1, (45 to 65) Hz (33 to 330) mV 330 mV to 1020 V (3.3 to 9) mA (9 to 33) mA (33 to 90) mA (90 to 330) mA (0.33 to 0.9) A (0.9 to 2.2) A (2.2 to 4.5) A (4.5 to 20) A (3.3 to 9) mA (9 to 33) mA (33 to 90) mA 1.1 mW/W + 2.8 nW 0.77 mW/W + 1.8 nW 1.1 mW/W + 33 nW 0.77 mW/W + 14 nW 0.99 mW/W + 0.33 µW 0.84 mW/W + 0.27 µW 0.92 mW/W + 0.12 µW 0.61 mW/W + 0.08 µW 0.92 mW/W + 0.12 µW 0.61 mW/W + 0.08 µW 0.92 mW/W + 0.72 µW Fluke 5522A
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3474.01) 01/05/2026 Page 8 of 9 Parameter/Equipment Range CMC2, 3(±) Comments AC Power – Generate, PF = 1, (45 to 65) Hz (cont) 330 mV to 1020 V (90 to 330) mA (0.33 to 0.9) A (0.9 to 2.2) A (2.2 to 4.5) A (4.5 to 20) A 0.61 mW/W + 0.51 µW 0.84 mW/W + 5.7 µW 0.69 mW/W + 4.4 µW 0.18 mW/W + 1.8 µW 0.17 mW/W + 25 µW Fluke 5522A II. Mechanical Parameter/Equipment Range CMC 2, 4, 5 (±) Comments Pressure – Measuring Equipment (0.2 to 25) psi (1.7 to 100) psi (1 to 1000) psi (1000 to 10 000) psi 0.000 62 % + 0.54 mpsi 0.000 49 % + 0.50 mpsi 0.0019 % + 0.23 mpsi 0.0055 % + 0.48 psi Ruska 2465-725 Ruska 2465-727 Ruska 2465-729 Fluke PPCH-G A70M III. Time & Frequency Parameter/Equipment Range CMC2, 5 (±) Comments Frequency – Measuring Equipment (10 to 40) Hz 40 Hz to 11.999 kHz 12 kHz to 10 MHz 73 µHz/Hz + 240 µHz 53 µHz/Hz + 47 mHz 12 µHz/Hz + 340 mHz Fluke 9500B _______________________________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration.
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3474.01) 01/05/2026 Page 9 of 9 3 The stated measured values are determined usi ng the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a fraction/percentage of the reading plus a fixed floor specification. 4 In the statement of CMC, percentages are percentage of reading, unless otherwise indicated. 5 The type of instrument or material being calib rated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 6 This scope meets A2LA’s P112 Flexible Scope Policy.
10ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.