Testing Center of Oriental Bluesky Titanium Technology Co.,
No. 9, Haitian Road, High-Tech Zone, Yantai, People's Republic of China, Yantai, China
Visit website- Accredited standards
- 17
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 17 standard numbers and the 12 official names we hold. When no standard matches, it searches the method text of every scope line.
ASTM17
ASTM A370Standard Test Methods and Definitions for Mechanical Testing of Steel Products
ASTM B117Standard Practice for Operating Salt Spray (Fog) Apparatus
ASTM B487Standard Test Method for Measurement of Metal and Oxide Coating Thickness by Microscopical Examination of Cross Section
ASTM E8Standard Test Methods for Tension Testing of Metallic Materials
ASTM E18Standard Test Methods for Rockwell Hardness of Metallic Materials
ASTM E21Standard Test Methods for Elevated Temperature Tension Tests of Metallic Materials
ASTM E45Standard Test Methods for Determining the Inclusion Content of Steel
ASTM E92Standard Test Methods for Vickers Hardness and Knoop Hardness of Metallic Materials
ASTM E112Standard Test Methods for Determining Average Grain Size
ASTM E139
ASTM E292
ASTM E340Standard Practice for Macroetching Metals and Alloys
Show all 17
ASTM E384Standard Test Method for Microindentation Hardness of Materials
ASTM E407Standard Practice for Microetching Metals and Alloys
ASTM E1409
ASTM E1447
ASTM E1941
ASTM E8/E8M; ASTM A370; ASTM E21; ASTM E139; ASTM E292; ASTM E18; ASTM E92; ASTM E384; ASTM E112; ASTM E45; GB/T 228.1; GB/T 4338; GB/T 230.1; GB/T 4340.1; GB/T 6394; GB/T 224; GB/T 10561; NASM 1312-8; NASM 1312-18; NASM 1312-13; NASM 1312-11; GJB 715.26A
GB/T 226; ASTM E340; GB/T 13298; GB/T 5168; ASTM E407; ASTM B487; GB/T 6462; ASTM B117; G85; NASM 1312-1; ASTM E1941; ASTM E1447; ASTM E1409; GB/T 20123; GB/T 20124; GB/T 11261; GB/T 24234; GB/T 4336; GB/T 11170
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
3 lines
ISO/IEC 17025
Active5948.01
The scope document we hold says it is valid until 2027-11-30.
Accredited scope, certificate 5948.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ASTM E8/E8M; ASTM A370; ASTM E21; ASTM E139; ASTM E292; ASTM E18; ASTM E92; ASTM E384; ASTM E112; ASTM E45; GB/T 228.1; GB/T 4338; GB/T 230.1; GB/T 4340.1; GB/T 6394; GB/T 224; GB/T 10561; NASM 1312-8; NASM 1312-18; NASM 1312-13; NASM 1312-11; GJB 715.26A | Metal | 400 to 900 ℃ |
| 2 | GB/T 226; ASTM E340; GB/T 13298; GB/T 5168; ASTM E407; ASTM B487; GB/T 6462; ASTM B117; G85; NASM 1312-1; ASTM E1941; ASTM E1447; ASTM E1409; GB/T 20123; GB/T 20124; GB/T 11261; GB/T 24234; GB/T 4336; GB/T 11170 | Steel | - |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
TESTING CENTER OF ORIENTAL BLUESKY
TITANIUM TECHNOLOGY CO., LTD
Yantai, Shandong, PEOPLE’S REPUBLIC OF CHINA
for technical competence in the field of
Mechanical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 4th day of November 2025.
_______________________
Mr. Trace McInturff Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 5948.01
Valid to November 30, 2027 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.