Shenzhen Most Technology Service Co.,
East A, 1 floor of New Aolin Factory buiding, Langshan Erlu, North District, Hi-tech Industry Park, Nanshan, Shenzhen, Guangdong, People's Republic of China, Shenzhen, Guangdong, China
- Accredited standards
- 3
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 3 standard numbers and the 2 official names we hold. When no standard matches, it searches the method text of every scope line.
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
FCC PART 15Radio Frequency Devices
RSS-GEN
ANSI C63.4:2014; FCC MP-5:1986; ANSI C63.10:2013; ANSI C63.10:2020; ANSI C63.26:2015; ANSI/TIA-603-E; ANSI/TIA-102.CAAA-E
ISO/IEC 17025:2017; 47 CFR, FCC Part 15 Subpart B (using ANSI C63.4:2014); 47 CFR, FCC Part 18 (using MP-5:1986); 47 CFR, FCC Part 15 Subpart C (using ANSI C63.10:2013, ANSI C63.10:2020); 47 CFR, FCC Part 15 Subpart E (using ANSI C63.10:2013, ANSI C63.10:2020); 47 CFR, FCC Parts 22, 24, 25, 27, 90, 95, 96, 97, and 101 (using ANSI C63.26:2015, ANSI/TIA-603-E-2016, or ANSI/TIA-102.CAAA-E); RSS-GEN; RSS-119; RSS-125; RSS-130; RSS-132; RSS-133; RSS-139; RSS-192; RSS-195; RSS-197; RSS-199; RSS-210; RSS-216; RSS-236; RSS-247; RSS-310; KDB Publication 447498 (D01)
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-06.
Scope as published by A2LA
3 lines
ISO/IEC 17025
Active6343.01
The scope document we hold says it is valid until 2027-09-30.
Accredited scope, certificate 6343.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; 47 CFR, FCC Part 15 Subpart B (using ANSI C63.4:2014); 47 CFR, FCC Part 18 (using MP-5:1986); 47 CFR, FCC Part 15 Subpart C (using ANSI C63.10:2013, ANSI C63.10:2020); 47 CFR, FCC Part 15 Subpart E (using ANSI C63.10:2013, ANSI C63.10:2020); 47 CFR, FCC Parts 22, 24, 25, 27, 90, 95, 96, 97, and 101 (using ANSI C63.26:2015, ANSI/TIA-603-E-2016, or ANSI/TIA-102.CAAA-E); RSS-GEN; RSS-119; RSS-125; RSS-130; RSS-132; RSS-133; RSS-139; RSS-192; RSS-195; RSS-197; RSS-199; RSS-210; RSS-216; RSS-236; RSS-247; RSS-310; KDB Publication 447498 (D01) | - | to 40 GHz |
| 2 | ANSI C63.4:2014; FCC MP-5:1986; ANSI C63.10:2013; ANSI C63.10:2020; ANSI C63.26:2015; ANSI/TIA-603-E; ANSI/TIA-102.CAAA-E | - | to 40000 MHz |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
SHENZHEN MOST TECHNOLOGY SERVICE CO., LTD.
Guangdong, People’s Republic of China
for technical competence in the field of
Electrical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 23rd day of July 2025.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 6343.01
Valid to September 30, 2027 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Labs with overlapping accredited scope in China
- DEKRA Testing and Certification (Suzhou) Co.,Suzhou, Jiangsu ProvinceA2LAShares 2 accredited test methodsANSI C63.4:2014RSS-GEN
- Guangdong KEYS Testing Technology Co.,Dongguan, GuangdongA2LAShares 2 accredited test methodsANSI C63.4:2014RSS-GEN
- Hunan Ecloud Testing Technology Co.,ChangshaA2LAShares 2 accredited test methodsANSI C63.4:2014RSS-GEN
- Intertek Testing Services (Shanghai FTZ) Co.,ShanghaiA2LAShares 2 accredited test methodsANSI C63.4:2014RSS-GEN
- Shenzhen HUAK Testing Technology Co.,ShenzhenA2LAShares 2 accredited test methodsANSI C63.4:2014RSS-GEN
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.