Landauer Ionizing Radiation Calibration Facility

2 Science Road, 60425, Glenwood, IL, United States

Visit website
A2LA 3028.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
3
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 3 scope lines.

A2LA certificate 3028.01 · 3 lines

LineMethodMatrixRange
1

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3028.01) Revised 01/27/2026 Page 1 of 2 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 LANDAUER IONIZING RADIATION CALIBRATION FACILITY 2 Science Road Glenwood, IL 60425 Abdallah Mirza Phone: 708 441 8436 CALIBRATION Valid To: July 31, 2026 Certificate Number: 3028.01 In recognition of the successful completion of the A2LA evaluation process, (including an assessment of the organization’s compliance with A2LA’s Calibration Program Requirements) accreditation is granted to this laboratory to perform the following calibrations1, 4: I. Ionizing Radiation & Radioactivity Parameter/Equipment Range CMC2, 3 (±) Comments Irradiation of Personnel Dosimeters – Cs 137 Air Kerma X-ray Air Kerma 9.8 mGy/min (30 to 300) kVp 3.4 % of rdg 4.6 % of rdg NMI traceable reference class ionization chambers calibrated in reproduced beams using replacement technique Radiation Protection Survey Instruments – Cs137 Exposure Cs137 Exposure (0.05 to 0.5) mR/hr 0.5 mR/hr to 35 R/hr 4.5 % of rdg 3.3 % of rdg NMI traceable reference class ionization chambers used to calibrate radiation beam air kerma or exposure rate ____________________________________________ 1 This laboratory offers commercial calibration service.
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3028.01) Revised 01/27/2026 Page 2 of 2 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 The contributions from the “best existing device” are not included in the CMC claim. 4 This scope meets A2LA’s P112 Flexible Scope Policy.
3ISO/IEC 17025:2017; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

2 Science Road, Glenwood, IL, 60425, US

41.54249, -87.60228

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.