Registers refreshed 2026-11-08.See refresh dates
Canada

Landau Gage

Windsor, Canada

Visit website
A2LA 3584.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
3
A2LA certificate
1
Sites in our directory
3
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 3 scope lines.

A2LA certificate 3584.01 · 3 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017-to 320 mm
2-Step Gages, Step Disks, Step Blocks, Bar Masters, Snap Gages, Flush Pins; Precision Balls; Threaded Plug Gages
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3584.01) 03/23/2026 Page 2 of 2 Parameter/Equipment Range CMC2, 3 (±) Comments Step Gages, Step Disks, Step Blocks, Bar Masters, Snap Gages, Flush Pins Up to 600 mm (5.1 + 0.0045L) µm Height masters & surface plate Precision Balls – Diameter Up to 50 mm (0.15 + 0.0055D) µm Pratt & Whitney Labmaster™ & gauge blocks Threaded Plug Gages – Major Diameter Simple Pitch Diameter Up to 50 mm Up to 50 mm (0.15 + 0.0055D) µm (1.4 + 0.0065D) µm P&W Labmaster™ & gauge blocks 3 wire method using P&W Labmaster™, gauge blocks & master wires _______________________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 In the statement of CMC, L is the numerical value of the nominal length of the device measured in millimeters for metric reference equipment ; D is the numerical value of the nominal diameter of the device measured in millimeters. 4 This scope meets A2LA’s P112 Flexible Scope Policy.
to 600 mm
3ISO/IEC 17025:2017--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Other Locations

2 other sites in this organization

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.