Wrentham Tool Group
155 Farm Street, 02019, Bellingham, MA, United States
Visit website- Scope lines
- 4
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 4 scope lines.
A2LA certificate 4180.01 · 4 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540.3-2006 | - | to 1 in |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4180.01) 04/21/2025 Page 2 of 3
Parameter/Equipment
Range
CMC2 (±)
Comments
Penetration Points,
Master Plugs & GO
NOGO Plug Gages
Type 1, Type 1A
Phillips, PoziDriv®,
Phillips II®, PSD®,
Type 3 Square Drive
Quadrex®
Mortorq®
Off set cruciform,
Torq-Set®, Tri-Wing®,
BNAE, Hi-Torq,
Spline-Lok, Hi-Lok, 12
Point
150 µin
3.2'
88 µin
150 µin
54 µin
3.2'
150 µin
Nikon microscope
Starrett video comparator
Starrett video comparator
Nikon microscope
P&W Supermicrometer™
Starrett video comparator
Nikon microscope
Fastener Recess External
GO NOGO Gages
12 Point, Mortorq®,
Hexlobe®
150 µin
54 µin
Nikon microscope,
P&W Supermicrometer™
Driver Bit Gages
Type1, Type 1A,
Phillips®, PoziDriv®,
Type 3 Square
240 µin
54 µin
150 µin
Indicator with master plugs
P&W Supermicrometer™
Nikon microscope
Driver Bit Test Blocks
Type1, Type 1A,
Phillips®, PoziDriv®,
Type 3 Square,
Hexstix®, Flat Tip,
PSD
150 µin
Nikon microscope
Indicators
(0 to 1) in
54 µin
P&W Supermicrometer™
with stage fixture
Thread Plugs X & W
Major Diameter
Pitch Diameter
0.060 in
1.0 in
54 µin
43 µin
P&W Supermicrometer™,
thread wires
Cylindrical Pins & Plugs
Up to 1 in
38 µin
P&W Supermicrometer™
_____________________________________________
1 This laboratory offers commercial calibration service. | 0 to 1 in |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4180.01) 04/21/2025 Page 3 of 3
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 4 | ISO/IEC 17025:2017; ANSI/NCSL Z540.3-2006 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.