Fred V Fowler Company
780 Dedham Street, 02021, Canton, MA, United States
Visit website- Scope lines
- 5
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 5 scope lines.
A2LA certificate 4072.01 · 5 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4072.01) 9/17/2024 Page 1 of 4
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
FRED V FOWLER COMPANY LLC
780 Dedham Street
Canton, MA. 02021
John Tang Phone: 800 788 2353
CALIBRATION
Valid To: April 30, 2026 Certificate Number: 4072.01
In recognition of the successful completion of the A2LA evaluation process (including an assessment of
the organization’s compliance with A2LA’s Calibration Program Requirements), accreditation is granted
to this laboratory to perform the following calibrations
1, 5.
I. Dimensional
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Bore Gages
Up to 8 in
(41 + 2.3D) µin + 0.6R
Comparison to ring
gages or gage blocks
Calipers
Up to 12 in
(12 to 80) in
(420 + 3.1L) µin
(560 + 6.5L) µin
Gage blocks
Cylindrical Pins/Plugs
Up to 8 in
Up to 2 in
(7.4 + 1.9D) µin
(12 + 1.1D) µin
Gage blocks with ULM:
Trimos horizontal
Trimos THV
Cylindrical Rings
Up to 8 in
(19 + 1.9D) µin
ULM (Trimos
horizontal)
Depth Measurement
Depth Gage
Depth Micrometer
Up to 32 in
Up to 6 in
(290 + 3.3L) µin
(61 + 0.67) µin
Gage blocks | to 12 in |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4072.01) 9/17/2024 Page 2 of 4
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Gage Blocks
Up to 4 in
(5 to 20) in
(4.8 + .9L) µin
(2.1 + 1.4L) µin
Master gage blocks
Height Gage
Up to 44 in
Up to 1010 mm
(65 + 1.5L) µin + 0.6R
(1.0 + 0.000 62L) µm + 0.6R
Gage blocks
CheckMaster
Indicators
Test
Drop
Drop
Up to 0.06 in
Up to 1 in
Up to 6 in
45 µin + 0.6R
51 µin + 0.6R
(55 + 2.5L) µin + 0.6R
Indicator calibrator
Comparison to gage
blocks
Indicator Calibrators
Up to 1 in
23 µin
Master gage blocks
Length/Micrometer
Standards
Up to 20 in
(3.1 + 3.7L) µin
Comparison to gage
blocks
LVDTs
Up to 1 in
Up to 1 in
47 µin
11 µin
Gage blocks
ULM (Trimos horizontal)
Micrometers
Inside
Outside
(Up to 20) in
Up to 6 in
(6 to 12) in
(12 to 20) in
(580 + 1L) µin
(39 + 5.4L) µin
(260 + 7.9L) µin
(930 + 11L) µin
ULM (Trimos horizontal)
Gage blocks
Micrometer Heads
Up to 2 in
(100 + 2.9L) µin
Gage blocks
Thickness Gages
(Feeler Type)
Up to 0.2 in
(33 + 95L) µin
ULM (Trimos horizontal) | to 44 in |
| 3 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4072.01) 9/17/2024 Page 3 of 4
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Thickness Gage
(Caliper Type)
Up to 6 in
(290 + 100L) µin
Gage blocks
Universal Measuring
Machines (Trimos
Horizontal)3
Length
Anvil Parallelism
Up to 500 mm
Up to 5000 mm
Up to 1 µm
(0.11 + 0.88L) µm
(0.52 + 0.058L) µm
0.089 µm
Laser interferometer
Laser interferometer
Ball probe gage
Coordinate Measuring
Machines3 (CMM)
Linear Displacement
Accuracy
Up to 20 in
(22 + 2.3L) µin
Gage block
Trimos THV
Length
Anvil Parallelism
Up to 4 in
Up to 20 µin
(12 + 0.92L) µin
7.8 µin
Master gage blocks
Ball probe gage
Steel Rulers
Up to 12 in
(140 + 0.97L) µin
Vision measuring
system
II. Mechanical
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Force – Measure3
Up to 12 N
0.079 N
Force gage
____________________________________________
1 This laboratory offers commercial calibration service. | to 12 N |
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 4072.01) 9/17/2024 Page 4 of 4
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavio r of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer’s site can normally be expected to be larger than the Calibration and
Measurement Capability Uncertainty (CMC) found on the A2LA scope. Allowance must be made for
aspects such as the environment at the place of calibration and for other possible adverse effects such as
those caused by transportation of the calibration equipment. The unusual allowance for the uncertainty
introduced by the item being calibrated, ( e.g., resolution) must also be considered and this, on its own,
could result in the actual measurement uncertainty achievable on a customer’s site being larger than the
CMC.
4 In the statement of CMC, L is the numerical value of the nominal length of the device measured in
associated units, R is the resolution of the unit under test and D is the numerical value of the nominal
diameter of the device measured in inches or meters.
5 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 5 | ISO/IEC 17025:20 17; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.