FindTestingLabs
Registers collected 2026-08-22.See collection dates
Cyprus

ITL - International Testing Laboratories (CY)

60 Arch Makariou Ave, Zavos Tower, Office 201, 3065, Limassol, Cyprus, Limassol, Cyprus

A2LA|5932.01ISO/IEC 17025Register collected 2026-08-22
Certificates
1
Scope items
8
Locations
1

Contact this laboratory

Watch this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at ITL - International Testing Laboratories (CY)?

Claim this profile to keep it accurate.

Claim this profile

Register record

A2LACollected
5932.01Active

Certificates and scope

1
A2LA

ISO/IEC 17025

Active

5932.01

View scope

Accredited scope, certificate 5932.01

DisciplineMethodMatrixRange
electricalIEC/EN/CAN/SI 60601-2-62; IEC/EN/CAN/SI 60601-2-63; IEC/EN/CAN/SI 60601-2-64; IEC/EN/CAN/SI 60601-2-65; IEC/EN/CAN/SI 60601-2-66; IEC/EN/CAN/SI 60601-2-68; IEC/EN/CAN/SI 60601-2-75; IEC/EN/CAN/SI 60601-2-83; IEC/EN 62366; EN 60601-2-25; ISO 15004, -2; IEC 80601-2-30, -35, -58, - 59, -60, -62, -71, -77,-78; ISO 80601-2-12, -13, -49, -55, - 56, -60, -61, -67, - 69, -70, -72, -74, -79, -80, -85, -87, 90; SI 80601 Parts 2.12, 2.13, 2.56, 2.59, 2.60; CAN/CSA-C22.2 No. 80601-2-13,-2-67, -2-72; IEC/EN/UL/CAN/SI 61010-1; IEC/EN/UL/CAN/SI 61010-2-40, -2-101, -2-010, -2-040, -2-201; IEC 61010-2-81 (Semi-/Automatic Lab Sample Analyzers); IEC/EN/UL/CAN/CSA/AS/NZS/J 60335-1; IEC/EN/CAN/CSA/UL/AS/NZS/J 60335-2-2; SI 900 Part 1; SI 900 Part 2.2; IEC/EN/CAN/CSA/UL/AS/NZS/J 60335-2-3; SI 900 Part 2.3; IEC/EN/CAN/CSA/AS/NZS/J 60335-2-5; SI 900 Part 2.5; IEC/EN/CAN/CSA/AS/NZS/J 60335-2-6; SI 900 Part 2.6; IEC/EN/CAN/CSA/AS/NZS/J 60335-2.7; SI 900 Part 2.7; IEC/EN/CAN/CSA/UL/AS/NZS 60335-2-8; SI 900 Part 2.8; IEC/EN/CAN/CSA/UL /AS/NZS/J 60335-2-9; SI 900 Part 2.9; IEC/EN/CAN/CSA/UL /AS/NZS/J 60335-2-11; SI 900 Part 2.11; IEC/EN/CAN/CSA/UL/AS/NZS/J 60335-2-12; SI 900 Part 2.12; IEC/EN/AS/NZS/J 60335-2-13; SI 900 Part 2.13; IEC/EN/CAN/CSA/UL/AS/NZS/J 60335-2-14; SI 900 Part 2.14; IEC/EN/CAN/CSA/UL/AS/NZS 60335-2-15; SI 900 Part 2.15--
electricalIEC/EN/UL/ANSI/CAN/SI 60601-1; IEC/EN/CAN/SI 60601-1-1; 1-3; -1-4, -1-6, -1-8, -1-9; -1-10; -1-11;1 -12; EN13718-1; IEC/EN/CAN/SI 60601-2-1; IEC/EN/CAN/SI 60601-2-2; IEC/EN/CAN/SI 60601-2-3; IEC/EN/CAN/SI 60601-2-4; IEC/EN/CAN/SI 60601-2-5; IEC/EN/CAN/SI 60601-2-9; IEC/EN/CAN/SI 60601-2-10; IEC/EN/CAN/SI 60601-2-11; IEC/EN/CAN/SI 60601-2-17; IEC/EN/CAN/SI 60601-2-18; IEC/EN/CAN/SI 60601-2-19; IEC/EN/CAN/SI 60601-2-20; IEC/EN/CAN/SI 60601-2-21; IEC/EN/CAN/SI 60601-2-22; IEC/EN/CAN/SI 60601-2-23; IEC/EN/CAN/SI 60601-2-24; IEC/EN/CAN/SI 60601-2-25; IEC/EN/CAN/SI 60601-2-26; IEC/EN/CAN/SI 60601-2-27; IEC/EN/CAN/SI 60601-2-28; IEC/EN/CAN/SI 60601-2-29; IEC/EN/CAN/SI 60601-2-30; IEC/EN/CAN/SI 60601-2-31; IEC/EN/CAN/SI 60601-2-32; IEC/EN/CAN/SI 60601-2-33; IEC/EN/CAN/SI 60601-2-34; IEC/EN/CAN/SI 60601-2-35; IEC/EN/CAN/SI 60601-2-36; IEC/EN/CAN/SI 60601-2-37; IEC/EN/CAN/SI 60601-2-38; IEC/EN/CAN/SI 60601-2-39; IEC/EN/CAN/SI 60601-2-40; IEC/EN/CAN/SI 60601-2-41; IEC/EN/CAN/SI 60601-2-43; IEC/EN/CAN/SI 60601-2-44; IEC/EN/CAN/SI 60601-2-45; IEC/EN/CAN/SI 60601-2-46; IEC/EN/CAN/SI 60601-2-47; IEC/EN/CAN/SI 60601-2-49; IEC/EN/CAN/SI 60601-2-50; IEC/EN/CAN/SI 60601-2-51; IEC/EN/CAN/SI 60601-2-52; IEC/EN/CAN/SI 60601-2-54; IEC/EN/CAN/SI 60601-2-57; IEC/EN/CAN/SI 60601-2-60--
electricalCISPR 32; EN 55032; KN 32; CNS 15936; CISPR 35; EN 55035; KN 35; IEC/EN 62233; IEC/EN 62311; IEC/EN 61000-6-1; IEC/EN 61000-6-2; IEC/EN 61000-6-3; IEC/EN 61000-6-4; IEC/EN 61000-3-2; KN 61000-3-2; IEC/EN 61000-3-3; KN 61000-3-2; ETSI EN/KN301 489-1,-3,-17,-19,-33, -52; ETSI EN/KN 300 328; ETSI EN 300 440; EN 300 440-1,-2; ETSI EN 301 893; ETSI EN 300 220-1,-2,-3,-4; ETSI EN 300 330-1,-2; CFR 47 Parts 15.207, 15.209, 15.225, 15.231, 15.240, 15.247, 15.249; 15.407; ISO 7637-2; E/ECE/324; ECE R 10, Regulation No. 10; IEC/SI 61851-1; MIL-STD-461C/D/E/F/G; RTCA/DO-160D/E/F/G--
electricalIEC/EN/CAN/CSA/AS/NZS 60335-2-16; SI 900 Part 2.16; IEC/EN/CAN/CSA/AS/NZS 60335-2-17; SI 900 Part 2.17; IEC/EN/CAN/CSA/AS/NZS 60335-2-21; IEC/EN/CAN/CSA/AS/NZS 60335-2-23; SI 900 Part 2.23; IEC/EN/CAN/CSA/UL/AS/NZS 60335-2-24; SI 900 Part 2.24; IEC/EN/CAN/CSA/AS/NZS 60335-2-25; SI 900 Part 2.25; IEC/EN/CAN/CSA/AS/NZS/J 60335-2-27; SI 900 Part 2.27; IEC/EN/CAN/CSA/UL /AS/NZS 60335-2-28; SI 900 Part 2.28; IEC/EN/CAN/CSA/UL /AS/NZS 60335-2-29; SI 900 Part 2.29; IEC/EN/CAN/CSA/UL /AS/NZS 60335-2-30; SI 900 Part 2.30; IEC/EN/CAN/CSA/UL /AS/NZS 60335-2-31; SI 900 Part 2.31; IEC/EN/CAN/CSA/UL /AS/NZS 60335-2-32; SI 900 Part 2.32; IEC/EN/CAN/CSA/UL /AS/NZS 60335-2-35; SI 900 Part 2.35; IEC/EN/CAN/CSA/UL /AS/NZS 60335-2-40; SI 994 Part-1, -3; IEC/EN/CAN/CSA/UL /AS/NZS 60335-2-41; IEC/EN/CAN/CSA/UL /AS/NZS 60335-2-45; SI 900 Part 2.45; IEC/EN/CAN/CSA/UL /AS/NZS 60335-2-52 SI 900 Part 2.52; IEC/EN/CAN/CSA/UL /AS/NZS 60335-2-55; SI 900 Part 2.55; IEC/EN/CAN/CSA/UL /AS/NZS 60335-2-59 SI 900 Part 2.59; IEC/EN/CAN/CSA/UL /AS/NZS 60335-2-60; SI 900 Part 2.60; IEC/EN/CAN/CSA/UL /AS/NZS 60335-2-65; IEC/EN/CAN/CSA/UL /AS/NZS 60335-2-66; SI 900 Part 2.66; IEC/EN/CAN/CSA/UL /AS/NZS 60335-2-74; SI 900 Part 2.74 IEC/EN/CAN/CSA/UL /AS/NZS 60335-2-75; SI 900 Part 2.75; IEC/EN/CAN/CSA/UL /AS/NZS 60335-2-76; SI 900 Part 2.76: IEC/EN/CAN/CSA/UL /AS/NZS 60335-2-77; SI 900 Part 2.77--
-IEC/EN/SI 60968; UL 1598; UL 1875; IEC/EN/SI 62560; IEC/EN/SI 62384-1; IEC/EN/SI 62031; IEC/EN/SI 62776; IEC 62034; UL 8800; IEC TR 62778; UL/EN/CAN/CSA/IEC/SI 60730-1; IEC/UL/EN/CAN/CSA/SI 60730-2.7,-2.9,-2.11,-2.15; EN 746-2; SI 74600 Part 2; EN 676; SI 67600 (Safety Related Parts of Control Systems); EN 50155; IEC/EN 60204-1; SI 60204 Part 1; IEC/EN 60204-32 (Machinery, Electrical, and Hoisting Machines); IEC/EN 60204-33; CAN/CSA C22.2 301; CAN/CSA C22.2 142; IEC/EN/UL/CAN/SI 60745-1; IEC/EN/SI 61439-1; IEC/EN/SI 61439-2; IEC/EN/SI 61439-3; IEC/EN/SI 61439-4; IEC/EN/SI 61439-5; IEC/CAN/CSA/EN 60825-1; IEC/CAN/CSA/EN 60825-2; IEC/CAN/CSA/EN 60825-9; SI 60825 Part 1; SI 60825 Part 2; MIL-STD-810; ETSI/EN_300019-1-0; ETSI/EN_300019-1-1; ETSI/EN_300019-1-2; ETSI/EN_300019-1-3; ETSI/EN_300019-1; ETSI/EN_300019-2; ETSI/EN_300019-3; ETSI/EN_300019-4; ETSI/EN_300019-5; ETSI/EN_300019-6; ETSI/EN_300019-7; ETSI/EN_300019-8; ETSI/EN_300019-30; EN 60945; IEC/UL/CAN/CSA/ANSI/EN/SI 60601-1-2; CISPR 11; EN 55011; KN 11; CNS 13803; CISPR 11; EN 55011; CISPR 13; EN 55013; CNS 13439; CISPR 14-1; EN 55014-1; CNS 13783-1; CISPR 14-2; EN 55014-2; CNS 13783-2; CISPR 15; EN 55015; CNS 14115; CISPR 22; EN 55022; KN 22; CNS 13438; CISPR 24; KN 24; CISPR 25; EN 55025; KN 25; CNS 14500--
----
-IEC/EN/UL/CAN 62368-1; SI 62368 Part 1; AS/NZS 62368.1; AS/NZS 62368.1; EN/IEC/UL 60950-1; EN/IEC/UL 60950-21; EN/IEC/UL 60950-22; SI 60950 Part 1, 21, 22; CAN CSA C22.2 No. 60950-1; CAN CSA C22.2 No. 60950-21; CAN CSA C22.2 No. 60950-22; CNS 14336-1; EN 61204-7; IEC 61204-7; UL 775; SI 990; UL 1642; UL 2054; UL 1989; IEC/EN/UL 62133-1,-2; SI 62133 Part 1, 2; IEC 60086-4; UN 38/3; IEC/EN/UL/CAN/SI 60065; IEC/EN/AS/CSA/NZS 61558-1; SI 61558 Part 1; IEC/EN/AS/NZS/CSA 61558-2-1, 2-2, 2-4, 2-5, 2-6, 2-7, 2-9, 2-12, 2-13, 2-16, 2-19, 2-20, 2-23; SI 61558 Parts 1, 2.1, 2.2, 2.4, 2.5, 2.6, 2.7, 2.9, 2.12, 2.13, 2.16, 2.19, 2.20, 2.23--
----

Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one.

Accreditation data collected from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.