Registers refreshed 2026-11-20.See refresh dates
United Kingdom

Eurofins Electrical & Electronic UK

Unit 5, Speedwell Road, WF10 5PY, Castleford, United Kingdom

Visit website
UKAS 1574ISO/IEC 17025Register refreshed 2026-11-20
Part of the Eurofins group: 318 sites in our directory.

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
56
UKAS certificate
1
Site in our directory
1
UKAS accredited scope

What this lab is accredited for

Our reading of the UKAS scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 56 standard numbers and the 25 official names we hold. When no standard matches, it searches the method text of every scope line.

ETSI17
ETSI EN 300 220-1
ETSI EN 300 220-2
ETSI EN 300 220-3-1
ETSI EN 300 328Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz band; Harmonised Standard for access to radio spectrum
ETSI EN 300 330Short Range Devices (SRD); Radio equipment in the frequency range 9 kHz to 25 MHz and inductive loop systems in the frequency range 9 kHz to 30 MHz; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
ETSI EN 300 440-1
ETSI EN 300 440-2
ETSI EN 301 489-1Some clauses

Limits written next to it

limited to those referred basic EN 301 489-1 V1.9.2 (2011-09) B, C, G

Some clauses. Written next to it on line 12 of UKAS certificate 1574.

ETSI EN 301 489-3
ETSI EN 301 489-17
ETSI EN 301 489-19
ETSI EN 301 489-52
Show all 17
ETSI EN 301 893
ETSI EN 301 908-1
ETSI EN 303 446-1
ETSI EN 303 446-2
ETSI EN 303 687
IEC 61000 series11
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-4
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test

Certificate says EN 61000-4-3. Probably the same standard; not checked against the EN document.

IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-9Electromagnetic compatibility (EMC) - Part 4-9: Testing and measurement techniques - Impulse magnetic field immunity test
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 61000-6-5
IEC 61000-6-8Some clauses

Limits written next to it

limited to those referred basic IEC 61000-6-8:2020 C, G

Some clauses. Written next to it on line 10 of UKAS certificate 1574.

IEC8
IEC 60227
IEC 60384-14
IEC 60695-11-10
IEC 60896-21
IEC 60945Maritime navigation and radiocommunication equipment and systems - General requirements - Methods of testing and required test results
IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
IEC 62366-1
IEC 62368-1Audio/video, information and communication technology equipment - Part 1: Safety requirements
IEC 60335 series4
IEC 60335-1Household and similar electrical appliances - Safety - Part 1: General requirements
IEC 60335-2-15
IEC 60335-2-29
IEC 60335-2-40
IEC 60601 series4
IEC 60601-1Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
IEC 60601-1-2Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
IEC 60601-1-6
IEC 60601-1-11Medical electrical equipment - Part 1-11: General requirements for basic safety and essential performance - Collateral Standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment
IEC 61010 series4
IEC 61010-1Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
IEC 61010-2-010
IEC 61010-2-081
IEC 61010-2-101Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-101: Particular requirements for in vitro diagnostic (IVD) medical equipment
ISO3
ISO 306Plastics - Thermoplastic materials - Determination of Vicat softening temperature (VST)
ISO 349-1
ISO 5149Mechanical refrigerating systems used for cooling and heating - Safety requirementsSome clauses

Limits written next to it

ISO 5149 Clause 22

Some clauses. Written next to it on line 16 of UKAS certificate 1574.

Other standards5
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
ANSI C63.10
CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission

Certificate says IEC 55014-1. Probably the same standard; not checked against the EN document.

CISPR 14-2Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard

Certificate says IEC 55014-2. Probably the same standard; not checked against the EN document.

FCC PART 15Radio Frequency DevicesExclusion

Limits written next to it

FCC Part 15, Subpart E Includes but not limited to:

Exclusion. Written next to it on line 28 of UKAS certificate 1574.

Read from the scope as published by UKAS. Register refreshed 2026-11-20.

Scope as published by UKAS

29 lines
UKAS

ISO/IEC 17025

Active

1574

View scope

Location

Unit 5, Speedwell Road, Castleford, WF10 5PY, GB

53.71504, -1.38702

Open in Maps

Accreditation data refreshed from the UKAS register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the UKAS entry linked above.