SAVOIE ANALYSES - SITE DE BONNEVILLE
53 rue du busard des roseaux, 74130, BONNEVILLE, France
Visit website- Accredited standards
- 37
- COFRAC certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the COFRAC scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 37 standard numbers and the 23 official names we hold. When no standard matches, it searches the method text of every scope line.
ISO15
ISO 5815-1Water quality - Determination of biochemical oxygen demand after n days (BODn) - Part 1: Dilution and seeding method with allylthiourea addition
ISO 6222Water quality - Enumeration of culturable micro-organisms - Colony count by inoculation in a nutrient agar culture medium
ISO 6878Water quality - Determination of phosphorus - Ammonium molybdate spectrometric method
ISO 7027-1Water quality - Determination of turbidity - Part 1: Quantitative methods
ISO 7393-2Water quality - Determination of free chlorine and total chlorine - Part 2: Colorimetric method using N,N-dialkyl-1,4-phenylenediamine, for routine control purposes
ISO 7899-1Water quality - Detection and enumeration of intestinal enterococci - Part 1: Miniaturized method (Most Probable Number) for surface and waste water
ISO 7899-2Water quality - Detection and enumeration of intestinal enterococci - Part 2: Membrane filtration method
ISO 9308-1Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 1: Membrane filtration method for waters with low bacterial background flora
ISO 9308-3Water quality - Detection and enumeration of Escherichia coli and coliform bacteria - Part 3: Miniaturized method (Most Probable Number) for the detection and enumeration of E. coli in surface and waste water
ISO 9963-1Water quality - Determination of alkalinity - Part 1: Determination of total and composite alkalinity
ISO 10523Water quality - Determination of pH
ISO 15705Water quality - Determination of the chemical oxygen demand index (ST-COD) - Small-scale sealed-tube method
ISO 15923-1Water quality - Determination of selected parameters by discrete analysis systems - Part 1: Ammonium, nitrate, nitrite, chloride, orthophosphate, sulfate and silicate with photometric detection
ISO 16266Water quality - Detection and enumeration of Pseudomonas aeruginosa - Method by membrane filtration
ISO 17289Water quality - Determination of dissolved oxygen - Optical sensor method
EN8
EN 872Water quality - Determination of suspended solids - Method by filtration through glass fibre filters
EN 1899-2Water quality - Determination of biochemical oxygen demand after n days (BODn) - Part 2: Method for undiluted samples
EN 12880Characterization of sludges - Determination of dry residue and water content
EN 16179
EN 25663Water quality - Determination of Kjeldahl nitrogen - Method after mineralization with selenium
EN 26461-2Water quality - Detection and enumeration of the spores of sulfite-reducing anaerobes (clostridia) - Part 2: Method by membrane filtration
EN 26777Water quality - Determination of nitrite - Molecular absorption spectrometric method
EN 27888Water quality - Determination of electrical conductivity
NF7
NF T90-004
NF T90-350
NF T 90-003
NF T 90-015-2
NF T 90-412
NF T 90-431
NF X 31-615
FD4
FD T 90-520Water quality - Technical sampling guide for the sanitary monitoring of water
FD T 90-522
FD T 90-523-1
FD T 90-523-2
T3
T 90-015-1
T 90-521
T 90-523-3
NF EN 16179; NF EN 12880; NF EN 872; NF EN ISO 10523; NF EN 27888; NF T 90-003; NF EN ISO 9963-1; NF EN ISO 7027-1; NF EN 25663; NF EN 1899-2; NF EN ISO 5815-1; ISO 15705; NF T 90-004; NF T 90-015-1; NF T 90-015-2; NF EN 26777; NF EN ISO 6878; NF EN ISO 15923-1
NF EN ISO 6222; NF EN ISO 9308-1; NF EN 26461-2; NF EN ISO 7899-2; NF EN ISO 16266; NF T 90-412; NF EN ISO 9308-3; NF EN ISO 7899-1; NF T 90-431
FD T 90-523-3; NF X 31-615; FD T 90-522; NF EN 27888; NF EN ISO 10523; NF EN ISO 7393-2; NF EN ISO 7027-1; NF ISO 17289
NF T 90-350
FD T 90-520; FD T 90-521; FD T 90-523-1; FD T 90-523-2
Read from the COFRAC scope document we downloaded on 2026-02-12. Register refreshed 2026-11-20.
Scope as published by COFRAC
6 lines
ISO/IEC 17025
Active1-7502
The scope document we hold says it is valid until 2030-12-31.
Accredited scope, certificate 1-7502
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | ENVIRONNEMENT / QUALITE DE L'EAU - MATRICES SOLIDES; ENVIRONMENT / WATER QUALITY - SOLID MATRICESShow page textExtracted from the scope document; tables may not line up. View scope for the original. Convention N° 300
LAB FORM 37 – Révision 10 – applicable au 1er juillet 2025 Page 1/7
Section Laboratoires
ATTESTATION D’ACCREDITATION
ACCREDITATION CERTIFICATE
N° 1-7502 rév. 1
Le Comité Français d'Accréditation (Cofrac) atteste que :
The French Committee for Accreditation (Cofrac) certifies that :
SAVOIE ANALYSES
N° SIREN : 390319192
Satisfait aux exigences de la norme NF EN ISO/IEC 17025 : 2017
Fulfils the requirements of the standard
et aux règles d’application du Cofrac pour les activités d’analyses/essais/étalonnages en :
and Cofrac rules of application for the activities of testing/calibration in :
ENVIRONNEMENT / QUALITE DE L'EAU - MATRICES SOLIDES
ENVIRONMENT / WATER QUALITY - SOLID MATRICES
réalisées par / performed by :
SAVOIE ANALYSES - Site de Bonneville
53 rue du busard des roseaux
74130 BONNEVILLE
FRANCE
et précisément décrites dans l’annexe technique jointe, à l’exclusion des activités réalisées dans les pays
listés dans le document GEN INF 16, dont la version en vigueur est disponible sur le site internet du Cofrac
(www.cofrac.fr).
and precisely described in the attached technical appendix, excluding activities performed in the countries listed in
the document GEN INF 16, the current version of which is available on our website (www.cofrac.fr).
L’accréditation suivant la norme internationale homologuée NF EN ISO/IEC 17025 est la preuve de la
compétence technique du laboratoire dans un domaine d’activités clairement défini et du bon
fonctionnement dans ce laboratoire d’un système de management adapté (cf. communiqué conjoint ISO-
ILAC-IAF en vigueur disponible sur le site internet du Cofrac www.cofrac.fr)
Accreditation in accordance with the recognised international standard NF EN ISO/IEC 17025 demonstrates the
technical competence of the laboratory for a defined scope and the proper operation in this laboratory of an
appropriate management system (see current Joint ISO -ILAC-IAF Communiqué available on Cofrac web site
www.cofrac.fr) .
Le Cofrac est signataire de l’accord multilatéral d’EA pour l’accréditation , pour les activités objets de la
présente attestation.
Cofrac is signatory of the European co -operation for Accreditation (EA) Multilateral Agreement for accreditation for
the activities covered by this certificate. | - |
| 2 | FD T 90-520; FD T 90-521; FD T 90-523-1; FD T 90-523-2 | Waste water | - |
| 3 | FD T 90-523-3; NF X 31-615; FD T 90-522; NF EN 27888; NF EN ISO 10523; NF EN ISO 7393-2; NF EN ISO 7027-1; NF ISO 17289 | Drinking water | - |
| 4 | NF EN 16179; NF EN 12880; NF EN 872; NF EN ISO 10523; NF EN 27888; NF T 90-003; NF EN ISO 9963-1; NF EN ISO 7027-1; NF EN 25663; NF EN 1899-2; NF EN ISO 5815-1; ISO 15705; NF T 90-004; NF T 90-015-1; NF T 90-015-2; NF EN 26777; NF EN ISO 6878; NF EN ISO 15923-1 | Sludge | - |
| 5 | NF EN ISO 6222; NF EN ISO 9308-1; NF EN 26461-2; NF EN ISO 7899-2; NF EN ISO 16266; NF T 90-412; NF EN ISO 9308-3; NF EN ISO 7899-1; NF T 90-431 | Surface water | - |
| 6 | NF T 90-350 | Cours d’eau | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in France
- CARSO - LABORATOIRE SANTÉ ENVIRONNEMENT HYGIÈNE DE LYON (CARSO - LSEHL)VENISSIEUX · ~526 kmCOFRACShares 6 accredited methods and materialsEN ISO 9308-1FD T 90-520Drinking water
- INOVALYS - SITE DE TOURSTOURS · ~320 kmCOFRACShares 5 accredited methods and materialsEN ISO 9308-1FD T 90-520Drinking water
- INOVALYS - SITE D'ANGERSANGERS · ~355 kmCOFRACShares 5 accredited methods and materialsEN ISO 9308-1FD T 90-520T 90-523-3
- IANESCOPOITIERS · ~414 kmCOFRACShares 5 accredited methods and materialsEN ISO 9308-1FD T 90-520T 90-523-3
- EUROFINS HYDROLOGIE SUD-OUESTGRADIGNAN · ~626 kmCOFRACShares 5 accredited methods and materialsEN ISO 9308-1FD T 90-520Drinking water
Accreditation data refreshed from the COFRAC register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the COFRAC entry linked above.