Registers refreshed 2026-11-06.See refresh dates
Sweden

TATAA Biocenter

Sofierogatan 3, 412 51, Göteborg, Sweden

Visit website
SWEDAC A003569-002SWEDAC a003569-002ISO/IEC 17025Register refreshed 2026-11-01

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
4
SWEDAC certificates
2
Site in our directory
1
SWEDAC accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 4 scope lines.

SWEDAC certificate A003569-002 · 2 lines

LineMethodMatrixRange
1-DNA; RNA; Kroppsvätskor; Vävnad
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

Beteckning Datum 2025-09-12 2024/731 Bilaga 1 Ackrediteringens omfattning Provning enligt SS-EN ISO/IEC 17025:2018 TATAA Biocenter AB Göteborg Ackrediteringsnummer 2054 A003569-002 Genetik Teknikområde Parameter Metod Mätprincip Provtyp Flex Typ av flex Kvantifiering av gener BIO-RAD CFX384 Touch Realtids-PCR DNA Ja 2 Realtids-PCR RNA Ja 2 Thermo Fisher QuantStudio 12K Realtids-PCR DNA Ja 2 Realtids-PCR RNA Ja 2 Thermo Fisher QuantStudio 7 Pro Realtids-PCR DNA Ja 2 Realtids-PCR RNA Ja 2 Provberedning BIO-RAD T100 Thermal Cycler cDNA-syntes RNA Ja 2 Manuell metod Extraktion av DNA Kroppsvätskor Ja 2 Extraktion av DNA Vävnad Ja 2 Extraktion av RNA Kroppsvätskor Ja 2 Extraktion av RNA Vävnad Ja 2 QIAGEN QIASymphony Extraktion av DNA Kroppsvätskor Ja 2 Extraktion av DNA Vävnad Ja 2 Extraktion av RNA Kroppsvätskor Ja 2 Extraktion av RNA Vävnad Ja 2 Sida 1 (2)
-
2

Extracted from the scope document; tables may not line up. View scope for the original.

Beteckning Datum 2025-09-12 2024/731 Bilaga 1 Ackrediteringens omfattning är flexibel enligt vad som anges i detta beslut. Det ackrediterade organet skall alltid kunna tillhandhålla en uppdaterad lista över den aktuella omfattningen för sin ackreditering. Provtagning omfattas inte av ackrediteringen. Om laboratoriet ändå själv utför provtagning omfattas provningen inte av ackrediteringen. Typ av flexibilitet 1 : - Införa ny version av standardmetod och göra redaktionella ändringar i icke-standardiserad metod. 2 : - Införa ny version av standardmetod och göra redaktionella ändringar i icke-standardiserad metod - Införa ny version och modifieringar av icke-standardiserad metod. Förfarandet ska vara likvärdigt - Införa ny parameter/komponent/undersökning - Införa nytt mätområde - Införa nytt material/nya produkter/matriser - Införa ny metod som är likvärdig med metoder som redan finns i ackrediteringsbeslutet Sida 2 (2)

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

SWEDAC certificate a003569-002 · 2 lines

LineMethodMatrixRange
1SS-EN ISO/IEC 17025:2018Tissue-
2

Extracted from the scope document; tables may not line up. View scope for the original.

Reference Date 2025-09-12 2024/731 Appendix 1 The accreditation does not cover sampling activities. If the laboratory, regardless of this, performs the sampling by itself, then the testing is not considered to be performed under accreditation. The scope of accreditation is flexible as specified in this decision. The accredited body must always retain a current list of the scope for which it is accredited. Type of flexible scope 1 : - Introduce new version of standard method and make editorial changes to non-standard method 2 : - Introduce new version of standard method and make editorial changes to non-standard method - Introduce new version and modifications of non-standard method. The procedure must be equivalent - Introduce new parameter/component/characteristics - Introduce new measurement range - Introduce new material/new products/matrices - Introduce new method equivalent to methods already in the accreditation decision Page 2 (2)

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Sofierogatan 3, Göteborg, 412 51, SE

57.69549, 11.99556

Open in Maps

Accreditation data refreshed from the SWEDAC register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the SWEDAC entry linked above.