Registers refreshed 2026-11-20.See refresh dates
Spain

CONSORCI DE MEDI AMBIENT I SALUT PÚBLICA DE LA GARROTXA (SIGMA) LABORATORI POLIVALENT DE LA GARROTXA

Ctra. de Riudaura, 94, 17800, Olot, Spain

ENAC 1115/LE2170ISO/IEC 17025Register refreshed 46 days ago

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
11
ENAC certificate
1
Site in our directory
1
ENAC accredited scope

What this lab is accredited for

Our reading of the ENAC scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 11 standard numbers and the 10 official names we hold. When no standard matches, it searches the method text of every scope line.

ISO7
ISO 7027-1Water quality - Determination of turbidity - Part 1: Quantitative methods
ISO 8467Water quality - Determination of permanganate index
ISO 9390Water quality - Determination of borate - Spectrometric method using azomethine-H
ISO 10304-1Water quality - Determination of dissolved anions by liquid chromatography of ions - Part 1: Determination of bromide, chloride, fluoride, nitrate, nitrite, phosphate and sulfate
ISO 10523Water quality - Determination of pH
ISO 11348-3Water quality - Determination of the inhibitory effect of water samples on the light emission of Vibrio fischeri (Luminescent bacteria test) - Part 3: Method using freeze-dried bacteria
ISO 11731Water quality - Enumeration of Legionella

Certificate says EN ISO 11731 2019-03 UBA Empfehlung 18. Probably the same standard; not checked against the EN document.

EN4
EN 872Water quality - Determination of suspended solids - Method by filtration through glass fibre filters
EN 1484Water analysis - Guidelines for the determination of total organic carbon (TOC) and dissolved organic carbon (DOC)
EN 6878
EN 27888Water quality - Determination of electrical conductivity

Read from the scope as published by ENAC. Register refreshed 2026-10-10.

Scope as published by ENAC

6 lines
ENAC

ISO/IEC 17025

Active

1115/LE2170

View scope

Accredited scope, certificate 1115/LE2170

LineMethodMatrixRange
1UNE-EN ISO 10523; UNE-EN 27888; UNE-EN ISO 7027-1Aguas de consumo; Aguas continentales; Aguas residualesSee scope document
2UNE-EN ISO 8467; SM 2320 B; SM 4500 NH3 D; ISO 9390; SM 4500 NO2 B; UNE-EN 1484; SM 3111 B; SM 3500-K B; SM 3500-Na B; SM 3111-B; SM 3113-B; UNE-EN ISO 10304-1; SM 2340 BAguas de consumoSee scope document
3SM 2330 B; UNE-EN ISO 10523; UNE-EN 27888; UNE-EN ISO 7027-1; UNE-EN ISO 8467; SM 2320 B; SM 4500 NH3 D; ISO 9390; SM 3500 Cr B; SM 4500 NO2 B; UNE-EN 1484; SM 3111 B; SM 3500-K B; SM 3500-Na BAguas de consumo; Aguas continentalesSee scope document
4SM 3111-B; SM 3113-B; UNE-EN ISO 10304-1; SM 2340 B; SM 2330 B; UNE-EN ISO 10523; UNE-EN 27888; UNE-EN 872; SM 4500 NH3 D; SM 2320 B; SM 5220 B; UNE 25663Aguas continentales; Aguas residualesSee scope document
5SM 3500 Cr B; ISO 9390; UNE-EN 6878; SM 4500-NO2 B; UNE-EN 1484; SM 3111-B; SM 3500-K B; SM 3500-Na B; SM 3111-B; SM 3113-B; UNE-EN ISO 10304-1Aguas residuales0.003 to mg/l
6UNE‐EN ISO 11348‐3; UNE-EN ISO 11731Aguas residuales; Aguas de consumo-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Ctra. de Riudaura, 94, Olot, 17800, ES

42.18375, 2.46954

Open in Maps

Accreditation data refreshed from the ENAC register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ENAC entry linked above.