EDISON NEXT ENVIRONMENT
Via Acqui 86, 10098, Rivoli Cascine Vica, Italy
Visit website- Accredited standards
- 15
- ACCREDIA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the ACCREDIA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 15 standard numbers and the 14 official names we hold. When no standard matches, it searches the method text of every scope line.
EN7
EN 12619Stationary source emissions - Determination of the mass concentration of total gaseous organic carbon - Continuous flame ionisation detector method
EN 14181Stationary source emissions - Quality assurance of automated measuring systems
EN 14789Stationary source emissions - Determination of volume concentration of oxygen - Standard reference method: Paramagnetism
EN 14790Stationary source emissions - Determination of the water vapour in ducts - Standard reference method
EN 14792Stationary source emissions - Determination of mass concentration of nitrogen oxides - Standard reference method: Chemiluminescence
EN 15058Stationary source emissions - Determination of the mass concentration of carbon monoxide - Standard reference method: non-dispersive infrared spectrometry
EN 27888Water quality - Determination of electrical conductivity
ISO7
ISO 5667-5Water quality - Sampling - Part 5: Guidance on sampling of drinking water from treatment works and piped distribution systems
ISO 5667-11Water quality - Sampling - Part 11: Guidance on sampling of groundwaters
ISO 7393-2Water quality - Determination of free chlorine and total chlorine - Part 2: Colorimetric method using N,N-dialkyl-1,4-phenylenediamine, for routine control purposes
ISO 9612Acoustics - Determination of occupational noise exposure - Methodology
ISO 12039Stationary source emissions - Determination of the mass concentration of carbon monoxide, carbon dioxide and oxygen in flue gas - Performance characteristics of automated measuring systems
ISO 16911-1Stationary source emissions - Manual and automatic determination of velocity and volume flow rate in ducts - Part 1: Manual reference method
ISO 19458Water quality - Sampling for microbiological analysis
Other standards1
APAT CNR IRSA 2100 Man 29 2003
UNI CEI EN ISO/IEC 17025:2018; APAT CNR IRSA 2100 Man 29 2003; ISO 5667-5:2006; UNI EN ISO 19458:2006; UNI EN 27888:1995; APAT CNR IRSA 1030 Man 29 2003; UNI EN ISO 7393-2:2018; ISO 5667-11:2009; UNI 9432:2011 + UNI EN ISO 9612:2011; EN 14181:2014; UNI EN 12619:2013/EC1:2013; EN 14792:2017; ISO 12039:2019 Annex A; DLgs n 152 03/04/2006 GU n 88 14/04/2006 Parte V all VI par 4.4; EN 15058:2017; EN 14789:2017; EN 14790:2017; UNI EN ISO 16911-1:2013 (solo Annex A); UNI 10802:2023 - escluso/except APP A,B,C
Read from the scope as published by ACCREDIA. Register refreshed 2026-11-06.
Scope as published by ACCREDIA
2 lines
ISO/IEC 17025
Active02194
Accredited scope, certificate 02194
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | UNI CEI EN ISO/IEC 17025:2018; APAT CNR IRSA 2100 Man 29 2003; ISO 5667-5:2006; UNI EN ISO 19458:2006; UNI EN 27888:1995; APAT CNR IRSA 1030 Man 29 2003; UNI EN ISO 7393-2:2018; ISO 5667-11:2009; UNI 9432:2011 + UNI EN ISO 9612:2011; EN 14181:2014; UNI EN 12619:2013/EC1:2013; EN 14792:2017; ISO 12039:2019 Annex A; DLgs n 152 03/04/2006 GU n 88 14/04/2006 Parte V all VI par 4.4; EN 15058:2017; EN 14789:2017; EN 14790:2017; UNI EN ISO 16911-1:2013 (solo Annex A); UNI 10802:2023 - escluso/except APP A,B,C | Waste water | See scope document |
| 2 | DM 13/09/1999 SO n 185 GU n 248 21/10/1999 Met I.1; UNI CEI EN ISO/IEC 17025:2018 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Italy
- EURO QUALITY SYSTEMSNovara · ~94 kmACCREDIAShares 2 accredited methods and materialsAPAT CNR IRSA 2100 Man 29 2003Waste water
- Chelab S.r.l.Cairo Montenotte · ~95 kmACCREDIAShares 2 accredited methods and materialsAPAT CNR IRSA 2100 Man 29 2003Waste water
- M.P. s.u.r.l.Cucciago · ~141 kmACCREDIAShares 2 accredited methods and materialsAPAT CNR IRSA 2100 Man 29 2003Waste water
- ALFA SolutionsReggio Emilia · ~246 kmACCREDIAShares 2 accredited methods and materialsAPAT CNR IRSA 2100 Man 29 2003Waste water
- CHEMICALAB del Dott. Domenico GioviniModena · ~273 kmACCREDIAShares 2 accredited methods and materialsAPAT CNR IRSA 2100 Man 29 2003Waste water
Accreditation data refreshed from the ACCREDIA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ACCREDIA entry linked above.