FindTestingLabs
Registers refreshed 2026-09-25.See refresh dates
Canada

Linear Optics (2003)

Plattsville, Canada

A2LA|2150.01ISO/IEC 17025Register refreshed 2026-09-25
Certificates
1
Scope items
3
Standards
0
Locations
3
One of 3 locations. View the organization

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at Linear Optics (2003)?

Claim this profile to keep it accurate.

Register record

A2LARefreshed
2150.01Active

Accredited standards

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Scope as published by A2LA

3 lines
A2LA

ISO/IEC 17025

Active

2150.01

The scope document we hold says it is valid until 2026-10-31.

View scope

Accredited scope, certificate 2150.01

LineDisciplineMethodMatrixRange
1dimensionalISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-to 18 in
2-
(A2LA Cert. No. 2150.01) 11/18/2024 Page 2 of 2 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 This scope meets A2LA’s P112 Flexible Scope Policy. 5 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches.
3-ISO/IEC 17025:2017; ANSI/NCSL Z540 -1-1994--

Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Other Locations

2 other sites in this organization

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.