Audio Precision Calibration Services
9290 S.W. Nimbus Ave., 97008, Beaverton, OR, United States
Visit website- Scope lines
- 6
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 6 scope lines.
A2LA certificate 2527.01 · 6 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; IEC 17025; ANSI/NCSL Z540-1-1994 AUDIO PRECISION CALIBRATION SERVICES 9290 | - | See scope document |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. A2LA Cert. No. 2527.01) 12/26/2024 Page 2 of 5
Parameter/Equipment
Range
CMC2, 3, 6 (±)
Comments
DC Voltage – Generate
(0 to 32.9999) mV
(33.000 to 77.999) mV
(78.000 to 119.999) mV
(120.000 to 329.999) mV
(330.00 to 779.99) mV
(0.780 00 to 3.299 99) V
(3.3000 to 7.7999) V
(7.8000 to 32.9999) V
(33.000 to 77.999) V
(78.000 to 329.999) V
2.8 µV
84 µV/V
40 µV/V
30 µV/V
15 µV/V
11 µV/V
14 µV/V
11 µV/V
18 µV/V
16 µV/V
Fluke 5520A/5522A
Rsource ≈ 50 Ω
Rsource ≈ 50 Ω
Rsource ≈ 50 Ω
Rsource ≈ 50 Ω
Resistance – Measure
(0 to 11.9999) Ω
(12.000 to 32.9999) Ω
(33.000 to 119.999) Ω
(120.00 to 1199.99) Ω
(1.2000 to 11.9999) kΩ
(12.000 to 119.999) kΩ
(120.00 to 1100.00) kΩ
0.30 mΩ
88 µΩ/Ω
40 µΩ/Ω
21 µΩ/Ω
21 µΩ/Ω
21 µΩ/Ω
43 µΩ/Ω
Agilent 3458A
10 Ω range
100 Ω range
1 kΩ range
10 kΩ range
100 kΩ range
1 MΩ range | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. A2LA Cert. No. 2527.01) 12/26/2024 Page 3 of 5
Parameter/Range
Frequency
CMC2, 3, 6 (±)
Comments
AC Voltage – Measure
(12.000 to 32.999) mV
(33.000 to 119.999) mV
(120.00 to 329.99) mV
(0.330 00 to 1.199 99) V
(1.2000 to 3.2999) V
(3.3000 to 11.9999) V
(12.000 to 32.999) V
(33.000 to 119.999) V
(120.00 to 329.99) V
(0.600 00 to 1.199 99) V
(1.2000 to 3.2000) V
1 kHz
1 kHz
1 kHz
1 kHz
1 kHz
1 kHz
1 kHz
1 kHz
1 kHz
100 Hz to 20 kHz
100 Hz to 20 kHz
0.032 %
0.023 %
0.030 %
0.019 %
0.030 %
0.019 %
0.045 %
0.035 %
0.059 %
0.053 %
0.13 %
Agilent 3458A
100 mV range, SSM mode
1 V range, SSM mode
10 V range, SSM mode
100 V range, SSM mode
1000 V range, SSM mode
1 V range, ANA mode
10 V range, ANA mode
AC Voltage – Generate
(1.650 to 47.999) mV
(48.000 to 77.999) mV
(78.000 to 329.999) mV
(330.00 to 779.99) mV
(0.780 00 to 3.2999) V
(3.3000 to 7.7999) V
(7.8000 to 32.9999) V
(33.000 to 329.999) V
1 kHz
1 kHz
1 kHz
1 kHz
1 kHz
1 kHz
1 kHz
1 kHz
0.035 %
0.028 %
0.020 %
0.027 %
0.019 %
0.027 %
0.019 %
0.021 %
Fluke 5520A/5522A
Test sources <48 mV are
obtained using a 200:1
custom attenuator driven
by Fluke 5520A/5522A
set for 200x the desired
voltage, Rsource ≈ 50 Ω
Rsource ≈ 50 Ω
Rsource ≈ 50 Ω | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. A2LA Cert. No. 2527.01) 12/26/2024 Page 4 of 5
Parameter/Range
Frequency
CMC2, 3, 6 (±)
Comments
AC Flatness – Measure
(1 kHz Reference)
(100 to 115) mV
(1.00 to 1.15) V
(5 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(5 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
0.0017 dB
0.0014 dB
0.0019 dB
0.0035 dB
0.0070 dB
0.026 dB
0.0015 dB
0.0013 dB
0.0019 dB
0.0035 dB
0.0070 dB
0.026 dB
Agilent 3458A
100 mV range, SSM
mode
1 V range, SSM mode
AC Flatness – Generate
(1 kHz Reference)
(100 to 320) mV
(1.00 to 3.20) V
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
0.0043 dB
0.0022 dB
0.0023 dB
0.0034 dB
0.0078 dB
0.020 dB
0.0028 dB
0.0020 dB
0.0022 dB
0.0029 dB
0.0058 dB
0.020 dB
Fluke 5520A/5522A
Rsource ≈ 50 Ω
Rsource ≈ 50 Ω
Rsource ≈ 50 Ω
Rsource ≈ 50 Ω
Rsource ≈ 50 Ω
Rsource ≈ 50 Ω
II. Time & Frequency
Parameter/Equipment
Range
CMC2, 5, 6 (±)
Comments
Frequency – Measure
1 Hz to 10 MHz
0.18 µHz/Hz
Agilent 53131 w/ opt
010 timebase
___________________________________________
1 This laboratory offers commercial calibration service for selected Audio Precision products only. | ||
| 5 | Guide to the Expression of Uncertainty in Measurement (GUM) | - | - |
| 6 | ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025; ANSI/NCSL Z540-1-1994 and R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.