Studio Chimico Ambientale
Via Portella della Ginestra, 38, 95045, Misterbianco, Italy
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at Studio Chimico Ambientale?
Claim this profile to keep it accurate.
Register record
- ACCREDIARefreshed
- 01221Active
Certificates and scope
1ISO/IEC 17025
Active01221
Accredited scope, certificate 01221
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | chemical | APAT CNR IRSA 2010 B Man 29 2003; APAT CNR IRSA 2030 Man 29 2003; APAT CNR IRSA 2060 Man 29 2003; UNI 10506:1996; EPA 5030C 2003; EPA 8260D 2018; APAT CNR IRSA 4020 Man 29 2003; EN ISO 9308-1:2014/A1:2017; EN ISO 7899-2:2003; UNI EN ISO 6222:2001 | Acque destinate al consumo umano; Drinking waters; Acque di piscina; Swimming pool waters; Acque di scarico; Waste waters; Acque sotterranee; Ground waters; Rifiuti liquidi acquosi; Aqueous liquid wastes; Acque naturali; Natural waters; Acque superficiali; Surface waters; Acque minerali naturali; Natural mineral waters; Acque trattate; Treated waters | 180 to 5500 mg/l |
| 2 | chemical | APAT CNR IRSA 7030 F Man 29 2003; EPA 3005A 1992; EPA 6010D 2018; ISO 6060:1989; UNI EN ISO 9377-2:2002; APAT CNR IRSA 2090 B Man 29 2003; UNI EN 12457-2:2004; APAT CNR IRSA 2030 Man 29 2003; DM 06/09/1994 GU n 288 10/12/1994 All 2 met B; DM 06/09/1994 GU n 288 10/12/1994 All 2 Met A; EPA 3550C 2007; EPA 8270E 2018; UNI 11184:2016; UNI EN 15936:2022; UNI EN 14039:2005 | Waste water | 0 to 80 UFC/ml |
| 3 | chemical | EPA 9045D 2004; UNI EN 15934:2012; UNI EN 12457-2:2004; UNI EN 1484:1999; APAT CNR IRSA 4020 Man 29 2003; EPA 6010D 2018; UNI EN 16192:2012; APAT CNR IRSA 2060 Man 29 2003; Reg CE 761/2009 23/07/2009 GU CE L220 24/08/2009 All II; MU 1978:06; DM 06/09/1994 GU n 288 10/12/1994; EPA 9040C 2004; EPA 3051A 2007; DM 13/09/1999 SO n 185 GU n 24 | Soil | 0.5 to 10 um |
| 4 | chemical | UNI EN ISO 16703:2011 | - | 12 to |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Italy
- AGROLAB Italia S.r.l. a socio unicoAltavilla Vicentina · ~936 kmACCREDIAShares 4 accredited methods and materialsEN ISO 16703:2011UNI EN 15934:2012Soil
- INNOVAZIONE CHIMICAMotta di Livenza · ~937 kmACCREDIAShares 4 accredited methods and materialsAPAT CNR IRSA 7030 F Man 29 2003EN ISO 16703:2011Soil
- ECOGEOLAB S.R.L. - a socio unicoBergamo · ~1,011 kmACCREDIAShares 4 accredited methods and materialsAPAT CNR IRSA 2010 B Man 29 2003APAT CNR IRSA 7030 F Man 29 2003Soil
- CENTRO ANALISI - Dott. Vecchio Giovanbattista & C.Aci Sant'Antonio · ~14 kmACCREDIAShares 3 accredited methods and materialsUNI EN 15934:2012SoilWaste water
- AmbienteMessina · ~100 kmACCREDIAShares 3 accredited methods and materialsAPAT CNR IRSA 7030 F Man 29 2003SoilWaste water
Accreditation data refreshed from the ACCREDIA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ACCREDIA entry linked above.