Dynisco

38 Forge Parkway, 02038, Franklin, MA, United States

Visit website
A2LA 3910.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
4
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 4 scope lines.

A2LA certificate 3910.01 · 4 lines

LineMethodMatrixRange
1--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3910.01) 01/28/2026 Page 1 of 3 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 DYNISCO INSTRUMENTS, LLC 38 Forge Parkway Franklin, MA 02038 Susana Rebello Phone: 508 422 0091 413 216 2186 Ext. 150 CALIBRATION Valid To: January 31, 2028 Certificate Number: 3910.01 In recognition of the successful co mpletion of the A2LA evaluation process (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 5: I. Dimensional Parameter/Equipment Range CMC 2 (±) Comments Bore Diameter3 Up to 12.7 mm 0.0029 mm Borescope Orifice3 – Bore Diameter Length (0.254 to 3.175) mm Up to 50.8 mm 0.0024 mm 0.0019 mm Pin gage Micrometer Piston Tip3 – Outside Diameter Linear Length Up to 12.7 mm Up to 19 mm 0.0024 mm 0.0024 mm Micrometer Digital Encoder3 – Linear Length Up to 25.4 mm 0.0028 mm Micrometer head
to 12.7 mm
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3910.01) 01/28/2026 Page 2 of 3 II. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 7 (±) Comments DC Voltage – Generate (0 to 90) mV 2.5 μV EDC CR103 III. Mechanical Parameter/Equipment Range CMC 2, 4, 6 (±) Comments Mass – Measure Up to 8 kg 0.47 g Scale Force 3 – Compression, Measure Up to 500 lbf Up to 5000 lbf 0.52 lbf 6.7 lbf Loadcell Time – Cross Head Dwell Time 3 Up to 10 min 0.64 sec Stopwatch Pressure – Measuring Equipment Transducers Dynisco/Viatran Transducers Up to 1500 psi Up to 5000 psi Up to 15 000 psi Up to 30 000 psi Up to 100 000 psi (-15 to 7.5) psi (-15 to 15) psi (-15 to 25) psi (-15 to 50) psi (-15 to 200) psi (-15 to 500) psi (-15 to 1000) psi (500 to 60 000) psi 0.6 psi 1.1 psi 2.8 psi 6.7 psi 43 psi 0.002 psi 0.003 psi 0.004 psi 0.007 psi 0.022 psi 0.052 psi 0.10 psi 0.014 % Transducer with meter: TS-1500 TS-5000 TS-15 000 TS-30k TS-100k Mensor sensors Pressurements deadweight tester M3820
3--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3910.01) 01/28/2026 Page 3 of 3 IV. Thermodynamics Parameter/Equipment Range CMC2, 4 (±) Comments Temperature – Measure Barrel Temperature 3 (15 to 350) °C 0.095 °C Digital PRT ________________________________________ 1 This laboratory does not offer commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (C MC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 The type of instrument or material being calibra ted is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 5 This scope meets A2LA’s P112 Flexible Scope Policy. 6 In the statement of CMC, percentages are percentages of reading, unless otherwise indicated. 7 The stated measured values are determined usi ng the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a fraction/percentage of the reading plus a fixed floor specification.
15 to 350 °C
4

Extracted from the scope document; tables may not line up. View scope for the original.

For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation. Accredited Laboratory A2LA has accredited DYNISCO, LLC Franklin, MA for technical competence in the field of Calibration This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This laboratory also meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 28th day of January 2026. __ _____________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 3910.01 Valid to January 31, 2028

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

38 Forge Parkway, Franklin, MA, 02038, US

42.58962, -72.61106

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.