FindTestingLabs
Registers refreshed 2026-09-25.See refresh dates
France

TRESCAL

24 - 26 RUE DE VILLENEUVE, 94150, RUNGIS, France

COFRAC|1-7149ISO/IEC 17025Register refreshed 2026-09-25
Certificates
1
Scope items
7
Standards
18
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at TRESCAL?

Claim this profile to keep it accurate.

Register record

COFRACRefreshed
1-7149Active

Accredited standards

18

Our reading of the COFRAC scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.

ISO

ISO 148-2Metallic materials - Charpy pendulum impact test - Part 2: Verification of testing machines
As written on the certificate · Line 2 (COFRAC 1-7149)

NF EN ISO 7500-1; ASTM E4; NF EN 12390-4; NF EN ISO 6506-2; ASTM E10; NF EN ISO 6508-2; ASTM E18; NF EN ISO 6507-2; ASTM E384; NF EN ISO 148-2; NF EN ISO 9513; ASTM E83

ISO 6506-2Metallic materials - Brinell hardness test - Part 2: Verification and calibration of testing machines
As written on the certificate · Line 2 (COFRAC 1-7149)

NF EN ISO 7500-1; ASTM E4; NF EN 12390-4; NF EN ISO 6506-2; ASTM E10; NF EN ISO 6508-2; ASTM E18; NF EN ISO 6507-2; ASTM E384; NF EN ISO 148-2; NF EN ISO 9513; ASTM E83

ISO 6507-2Metallic materials - Vickers hardness test - Part 2: Verification and calibration of testing machines
As written on the certificate · Line 2 (COFRAC 1-7149)

NF EN ISO 7500-1; ASTM E4; NF EN 12390-4; NF EN ISO 6506-2; ASTM E10; NF EN ISO 6508-2; ASTM E18; NF EN ISO 6507-2; ASTM E384; NF EN ISO 148-2; NF EN ISO 9513; ASTM E83

ISO 6508-2Metallic materials - Rockwell hardness test - Part 2: Verification and calibration of testing machines and indenters
As written on the certificate · Line 2 (COFRAC 1-7149)

NF EN ISO 7500-1; ASTM E4; NF EN 12390-4; NF EN ISO 6506-2; ASTM E10; NF EN ISO 6508-2; ASTM E18; NF EN ISO 6507-2; ASTM E384; NF EN ISO 148-2; NF EN ISO 9513; ASTM E83

ISO 7500-1Metallic materials - Calibration and verification of static uniaxial testing machines - Part 1: Tension/compression testing machines - Calibration and verification of the force-measuring system
As written on the certificate · Line 2 (COFRAC 1-7149)

NF EN ISO 7500-1; ASTM E4; NF EN 12390-4; NF EN ISO 6506-2; ASTM E10; NF EN ISO 6508-2; ASTM E18; NF EN ISO 6507-2; ASTM E384; NF EN ISO 148-2; NF EN ISO 9513; ASTM E83

ISO 9513Metallic materials - Calibration of extensometer systems used in uniaxial testing
As written on the certificate · Line 2 (COFRAC 1-7149)

NF EN ISO 7500-1; ASTM E4; NF EN 12390-4; NF EN ISO 6506-2; ASTM E10; NF EN ISO 6508-2; ASTM E18; NF EN ISO 6507-2; ASTM E384; NF EN ISO 148-2; NF EN ISO 9513; ASTM E83

ASTM

ASTM E4Name not checked yet
As written on the certificate · Line 2 (COFRAC 1-7149)

NF EN ISO 7500-1; ASTM E4; NF EN 12390-4; NF EN ISO 6506-2; ASTM E10; NF EN ISO 6508-2; ASTM E18; NF EN ISO 6507-2; ASTM E384; NF EN ISO 148-2; NF EN ISO 9513; ASTM E83

ASTM E10Standard Test Method for Brinell Hardness of Metallic Materials
As written on the certificate · Line 2 (COFRAC 1-7149)

NF EN ISO 7500-1; ASTM E4; NF EN 12390-4; NF EN ISO 6506-2; ASTM E10; NF EN ISO 6508-2; ASTM E18; NF EN ISO 6507-2; ASTM E384; NF EN ISO 148-2; NF EN ISO 9513; ASTM E83

ASTM E18Standard Test Methods for Rockwell Hardness of Metallic Materials
As written on the certificate · Line 2 (COFRAC 1-7149)

NF EN ISO 7500-1; ASTM E4; NF EN 12390-4; NF EN ISO 6506-2; ASTM E10; NF EN ISO 6508-2; ASTM E18; NF EN ISO 6507-2; ASTM E384; NF EN ISO 148-2; NF EN ISO 9513; ASTM E83

ASTM E83Name not checked yet
As written on the certificate · Line 2 (COFRAC 1-7149)

NF EN ISO 7500-1; ASTM E4; NF EN 12390-4; NF EN ISO 6506-2; ASTM E10; NF EN ISO 6508-2; ASTM E18; NF EN ISO 6507-2; ASTM E384; NF EN ISO 148-2; NF EN ISO 9513; ASTM E83

ASTM E384Standard Test Method for Microindentation Hardness of Materials
As written on the certificate · Line 2 (COFRAC 1-7149)

NF EN ISO 7500-1; ASTM E4; NF EN 12390-4; NF EN ISO 6506-2; ASTM E10; NF EN ISO 6508-2; ASTM E18; NF EN ISO 6507-2; ASTM E384; NF EN ISO 148-2; NF EN ISO 9513; ASTM E83

IEC 60068 series

IEC 60068-3-5Name not checked yet
As written on the certificate · Line 3 (COFRAC 1-7149)

FD X15-140; FDV 08-601; NF EN 60068-3-5; NF EN 60068-3-7; NF EN 60068-3-11; NF EN 60068-3-6

IEC 60068-3-6Name not checked yet
As written on the certificate · Line 3 (COFRAC 1-7149)

FD X15-140; FDV 08-601; NF EN 60068-3-5; NF EN 60068-3-7; NF EN 60068-3-11; NF EN 60068-3-6

IEC 60068-3-7Name not checked yet
As written on the certificate · Line 3 (COFRAC 1-7149)

FD X15-140; FDV 08-601; NF EN 60068-3-5; NF EN 60068-3-7; NF EN 60068-3-11; NF EN 60068-3-6

IEC 60068-3-11Name not checked yet
As written on the certificate · Line 3 (COFRAC 1-7149)

FD X15-140; FDV 08-601; NF EN 60068-3-5; NF EN 60068-3-7; NF EN 60068-3-11; NF EN 60068-3-6

EN

EN 285Name not checked yet
As written on the certificate · Line 7 (COFRAC 1-7149)

NF EN 554 § 5.3 Annexes A 3.3 et A3.6 (1994); NF EN 285 (2009) § 8.2.3 et § 18

EN 554Name not checked yet
As written on the certificate · Line 7 (COFRAC 1-7149)

NF EN 554 § 5.3 Annexes A 3.3 et A3.6 (1994); NF EN 285 (2009) § 8.2.3 et § 18

EN 12390-4Name not checked yet
As written on the certificate · Line 2 (COFRAC 1-7149)

NF EN ISO 7500-1; ASTM E4; NF EN 12390-4; NF EN ISO 6506-2; ASTM E10; NF EN ISO 6508-2; ASTM E18; NF EN ISO 6507-2; ASTM E384; NF EN ISO 148-2; NF EN ISO 9513; ASTM E83

Scope as published by COFRAC

7 lines
COFRAC

ISO/IEC 17025

Active

1-7149

View scope

Accredited scope, certificate 1-7149

LineDisciplineMethodMatrixRange
1--Chemical and biological products, medical devices-
2mechanicalNF EN ISO 7500-1; ASTM E4; NF EN 12390-4; NF EN ISO 6506-2; ASTM E10; NF EN ISO 6508-2; ASTM E18; NF EN ISO 6507-2; ASTM E384; NF EN ISO 148-2; NF EN ISO 9513; ASTM E83Machines de traction; Machines de compression; Machines hydrauliques pour des essais de compression des matériaux durs; Machines de dureté BRINELL; Machines de dureté ROCKWELL; Machines de dureté VICKERS; Moutons pendules équipés d’un couteau de rayon de courbure de 2 mm; Extensomètres-
3mechanicalFD X15-140; FDV 08-601; NF EN 60068-3-5; NF EN 60068-3-7; NF EN 60068-3-11; NF EN 60068-3-6Thermostatic enclosures-80 to 600 °C
4mechanicalPCCL-ROI-0001; L06-450Enceintes climatiques et thermostatiques sous vide; Enceinte à brouillard salin; Bains; Enceintes de traitement thermique-80 to 1250 °C
5mechanicalAMS2750; PCCL-ROI-0002; PCEM-ROI-0045Enceinte de traitement thermique; Chaîne de température; Indicateur pour couple thermoélectrique; Indicateur pour thermorésistance0 to 1250 °C
6mechanicalPCCL-ROI-0003; PCCL-ROI-0001; PT-00BI-09Four à moufle; Thermocycleur30 to 1250 °C
7mechanicalNF EN 554 § 5.3 Annexes A 3.3 et A3.6 (1994); NF EN 285 (2009) § 8.2.3 et § 18Petits et grands stérilisateurs à la vapeur d’eau-

Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

24 - 26 RUE DE VILLENEUVE, RUNGIS, 94150, FR

48.74840, 2.34727

Open in Maps

Accreditation data refreshed from the COFRAC register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the COFRAC entry linked above.