MSI-Viking Gage, LLC.

7044 Fairfield Business Center, 45014, Fairfield, OH, United States

Visit website
A2LA 1387.04ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
17
A2LA certificate
1
Sites in our directory
3
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 17 scope lines.

A2LA certificate 1387.04 · 17 lines

LineMethodMatrixRange
1--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1387.04) Revised 3/5/2025 Page 1 of 17 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 MSI-VIKING GAGE, LLC. 7044 Fairfield Business Center Fairfield, OH 45014 Brian Bunnell Phone: 513 829 0900 CALIBRATION Valid To: August 31, 2026 Certificate Number: 1387.04 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with R205 - A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory at the location listed below to perform the following calibrations 1, 9: I. Dimensional Parameter/Equipment Range CMC2, 4 (±) Comments Bore Micrometers Up to 8 in (16 + 4.9D) μin Master rings Dial Bore Gages (Bore Gage w/ Indicator) Up to 4 in (27 + 1.6L) μin (17 + 4.5L) μin ULM Master rings Calipers3 50 μin Resolution: 100 μin Resolution 500 μin Resolution Up to 6 in (6 to 12) in (12 to 24) in (24 to 48) in Up to 6 in (6 to 12) in (12 to 24) in (24 to 48) in Up to 6 in (6 to 12) in (12 to 24) in (24 to 48) in (48 to 80) in (35 + 0.58L) μin (42 + 1.9L) μin (42 + 2.6L) μin (34 + 3.2L) μin (61 + 0.34L) μin (64 + 1.4L) μin (62 + 2.2L) μin (49 + 3.1L) μin (290 + 0.073L) μin (290 + 1.9L) in (290 + 0.75L) μin (270 + 1.5L) μin (250 + 2.0L) μin Gage blocks
to 80 in
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1387.04) Revised 3/5/2025 Page 2 of 17 Parameter/Equipment Range CMC2, 4 (±) Comments Calipers3 (cont) 0.001 in Resolution 50uin Res 100 uin Res 500 uin Res 0.001 in Res Up to 6 in (6 to 12) in (12 to 24) in (24 to 48) in (48 to 80) in Up to 12 in Up to 12 in Up to 12 in Up to 12 in (580 + 0.037L) μin (580 + 0.19L) μin (580 + 0.39L) μin (570 + 0.81L) μin (550 + 1.2L) μin (240 + 1.5L) μin (250 + 0.15L) μin (370 + 0.98L) μin (620 + 0.059L) μin Gage blocks Caliper checker Caliper Checkers Up to 12 in (90 + 0.92L) μin Electronic indicator amplifier, gage blocks Caliper Gage3 – Internal, External Up to 8.0 in (18 + 1.9L) μin Gage blocks Depth Step Gages (0.5 to 11.5) in (13 + 2.1L) μin Electronic indicator amplifier, gage blocks Cylindrical Ring Gages3 (0.425 to 18) in (6.1 + 4.1D) μin Universal length machine, master rings Disc, Plug & Pin Gages3 Up to 20 in (12 + 1.0D) μin Universal length machine Electronic Indicator Amplifier3 Up to 0.02 in 9.3 μin Gage blocks, optical flat
3--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1387.04) Revised 01/31/2025 Page 3 of 17 Parameter/Equipment Range CMC2, 4 (±) Comments Attribute Gage Up to 12 in Up to 27 in Ext. Measurement Up to 11.5 in Int. Measurement Up to 6 in (130 + 5.4L) μin (12 + 1.0D) μin (12 + 2.1L) μin 0.000 30 in Vision system Universal length machine Electronic indicator amplifier, gage blocks Rings, plugs, hand tools Gage Blocks – Length Only Up to 4 in (4.1 + 1.8L) μin Gage block comparator, master gage blocks Height Gages3 Up to 40 in (290 + 0.94L) µin Gage blocks Indicators/LVDTs3 Up to 12 in 0.000 01 in 0.000 05 in 0.0001 in 0.0005 in 0.001 in (17 + 3.1L) μin (41 + 2.4L) μin (59 + 1.3L) μin (290 + 0.3L) μin (580 + 0.85L) μin ULM Length Standards3 Up to 20 in (14 + 1.4D) μin Universal length machine Levels3 Up to 12 in 140 μin Surface plate, sine bar, gage blocks
to 12 in
4--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1387.04) Revised 3/5/2025 Page 4 of 16 Parameter/Equipment Range CMC2, 4 (±) Comments Micrometers3 – Groove Depth Inside Specialty Micrometers Up to 12 in (12 to 24) in (24 to 48) in Up to 4 in Up to 16 in Up to 20 in Up to 4 in (7.9 + 3.3L) μin + 0.6R (11 + 3.1L) μin + 0.6R (3.7 – 3.1L) μin + 0.6R (91 + 3.9L)µin + 0.6R (580 + 3.3L) μin (32 + 1.8D) μin + 0.6R (0.96 + 16L) μin Gage blocks ULM Indicator Calibrators3 (Mic Head Type) Up to 1 in (22 + 4.2L) μin ULM Plain Pins Class ZZ3 Up to 2 in 37 μin High accuracy micrometer Protractor – Bevel Digital3 Up to 180° Up to 90° 11 arcsec or 0.003° 27 arcsec Vision system Sine plate, gage blocks Snap Gage3 – Flatness of Anvils Size Up to 1 in (Up to 20) in 3.3 μin (57 + 1.1L) μin Optical flat Gage blocks Steel Rules3 Up to 96 in Up to 39 in (300 + 0.27L) μin 0.0046 in Vision system Direct comparison
to 180 °
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1387.04) Revised 3/5/2025 Page 5 of 16 Parameter/Equipment Range CMC2, 4 (±) Comments Steel Tapes3 Up to 100 ft 0.05 in Direct comparison Thickness & Feeler Gage3 Up to 2 in (12 + 1.0D) μin Universal length machine (ULM) Thread Measuring Wires3 (4 to 80) TPI 8.1 μin Universal length machine, gage blocks, master pins Angle Blocks Up to 90° 11 arcsec or 0.003° Vision system Screw Thread Micrometer Standards Up to 12 in (130 + 5.4L) μin Vision system Thread Plugs3 – Major Diameter Pitch Diameter Tapered Thread Plug Gage – Pitch Diameter Step Up to 8 in Up to 80 TPI Up to 4 in Up to 1 in (7.6 + 1.3D) μin (68 + 1.2D) μin (41 + 4.5D) μin 45 μin Universal length machine Universal length machine, thread measuring wires Universal length machine, gage blocks Gage blocks Universal Measuring Machines/Bench Micrometers3 Up to 12 in (8 + 2.4L) μin Gage blocks Laser Micrometers3 Up to 1 in (27 + 1.9D) µin Class XX master pins Radius Gages Up to 12 in (140 + 5.2L) μin Vision system
6--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1387.04) Revised 3/5/2025 Page 6 of 16 Parameter/Equipment Range CMC2, 4 (±) Comments Surface Finish Testers3 – Ra, Rz (2 to 500) µin 2.5 µin Master surface finish patch Surface Finish Standards3 – Ra, Rz (2 to 500) µin 6.2 µin Direct comparison to master surface patch II. Dimensional Testing/Calibration5 Parameter/Equipment Range CMC2, 4, 8 (±) Comments Surface Finish – Measure (2 to 500) µin 5.2 µin Master surface finish patch Flatness – Measure Up to 20 in Up to 2 in 31 μin 4.8 μin Electronic indicator Optical flat Parallelism – Measure Up to 20 in 14 μin Electronic indicator amplifier Radius – Measure Up to 12 in Up to 304.8 mm (140 + 5.2L) μin (0.44 + 0.0011L) μm Vision system Straightness – Measure Up to 12 in 22 μin Electronic indicator amplifier Video Measurement5 – X, Y Axis Up to 12 in Up to 304.8 mm (140 + 5.2L) μin (0.44 + 0.0011L) μm Vision system Angular Measurements5 Up to 360° 38 arcsec or 0.010° Optical comparator
2 to 500 µin
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1387.04) Revised 3/5/2025 Page 7 of 16 III. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 7 (±) Comments DC Voltage – Generate3 (0 to 329.9999) mV (0 to 3.2999) V (0 to 32.9999) V (33 to 329.9999) V (100 to 1020) V 24 uV/V + 3 uV 63 uV/V + 5 uV 60 uV/V + 50 uV 66 uV/V + 500 µV 66 uV/V + 1500 µV Fluke 5500A DC Voltage – Measure3 (0 to 100) mV (0.1 to 1) V (1 to 10) V (10 to 100) V (100 to 1000) V 6.2 µV/V + 0.30 µV 3.2 µV/V + 0.30 µV 1.1 µV/V + 0.50 µV 3.4 µV/V + 30 µV 6.6 µV/V + 0.10 mV Agilent 3458A DC High Voltage – Measure (1 to 9) kV 0.000 54 V/V – 0.12 V High voltage meter DC Current – Generate3 (0 to 3.299 99) mA (0 to 33) mA (0 to 330) mA (0 to 2.2 A (0 to 11) A 0.016 % + 0.05 uA 0.013 % + 0.25 uA 0.015 % + 3.3 uA 0.036 % + 44 uA 0.072 % + 330 uA Fluke 5500A DC Current – Measure3 (10 to 100) µA 100 µA to 1 mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A 25 µA/A + 0.8 nA 23 µA/A + 5.0 nA 23 µA/A + 50 nA 37 µA/A + 0.50 µA 0.013 % + 10 µA Agilent 3458A
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1387.04) Revised 3/5/2025 Page 8 of 16 Parameter/Range Frequency CMC2, 7 (±) Comments AC Voltage – Generate3 (1 to 32.999) mV (33 to 329.999) mV (0.33 to 3.29999) V (3.3V to 32.9999) V (33 to 329.999) (330 to 1020) V (10 to 45) Hz 45Hz to 10kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45Hz to 10kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45Hz to 10kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45Hz to 10kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45Hz to 1kHz (1 to 10) kHz (10 to 20) kHz 45Hz to 1kHz (1 to 5) kHz (5 to 10) kHz 0.42 % + 20 µV 0.18 % + 20 µV 0.024 % + 20 µV 0.30 % + 20 µV 0.42 % + 33 µV 1.2 % + 60 µV 0.30 % + 50 µV 0.06 % + 20 µV 0.12 % + 20 µV 0.19 % + 40 µV 0.29 % + 170 µV 0.84 % + 330 µV 0.18 % + 250 µV 0.04 % + 60 µV 0.096 % + 60 µV 0.16 % + 300 µV 0.29 % + 1700 µV 0.60 % + 3300 µV 0.18 % + 2500 µV 0.048 % + 600 µV 0.096 % + 2600 µV 0.23 % + 5000 µV 0.29 % + 1.7 mV 0.06 % + 6.6 mV 0.096 % + 15 mV 0.10 % + 33 mV 0.06 % + 80 mV 0.24 % + 100 mV 0.24 % + 500 mV Fluke 5500A
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1387.04) Revised 3/5/2025 Page 9 of 16 Parameter/Range Frequency CMC2, 7 (±) Comments AC Voltage – Measure3 Up to 10 mV (10 to 100) mV 100 mV to 1 V (1 to 10) V (10 to 100) V (100 to 750) V (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 1) MHz (1 to 2) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 2) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 to 1 MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz 0.030 % + 3.0 µV 0.020 % + 1.1 µV 0.040 % + 1.1 µV 0.11 % + 1.1 µV 0.51 % + 1.1 µV 4.1 % + 2.0 µV 0.0080 % + 4.0 µV 0.0080 % + 2.0 µV 0.016 % + 2.0 µV 0.031 % + 2.0 µV 0.081 % + 2.0 µV 0.34 % + 10 µV 1.1 % + 10 µV 1.6 % + 10 µV 0.0090 % + 40 µV 0.0070 % + 20 µV 0.017 % + 20 µV 0.036 % + 20 µV 0.82 % + 20 µV 0.31 % + 100 µV 1.1 % + 100 µV 1.6 % + 100 µV 0.0080 % + 0.40 mV 0.0080 % + 0.20 mV 0.015 % + 0.20 mV 0.031 % + 0.20 mV 0.080 % + 0.20 mV 0.30 % + 1.0 mV 1.0 % + 1.0 mV 0.030 % + 4.0 mV 0.030 % + 2.0 mV 0.030 % + 2.0 mV 0.040 % + 2.0 mV 0.13 % + 2.0 mV 0.040 % + 4.0 mV 0.040 % + 2.0 mV 0.060 % + 2.0 mV 0.14 % + 2.0 mV 0.40 % + 2.0 mV Agilent 3458A opt 002
10--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1387.04) Revised 3/5/2025 Page 10 of 16 Parameter/Range Frequency CMC2, 7 (±) Comments AC High Voltage – Measure (1 to 10) kV 60 Hz 0.0015 V/V + 0.34 V High voltage meter AC Current – Measure3 (5 to 100) μA (1 to 100) mA (0.1 to 1) A (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 10 kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 1 kHz (5 to 20) kHz (20 to 50) kHz (50 to 100) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (5 to 20) kHz (20 to 50) kHz 0.57 % rdg + 0.030 % rng 0.18 % rdg + 0.030 % rng 0.07 % rdg + 0.030 % rng 0.07 % rdg + 0.030 % rng 0.55 % rdg + 0.020 % rng 0.18 % + 20 μA 0.080 % + 20 μA 0.043 % rdg + 0.02 % rng 0.090 % rdg + 0.02 % rng 0.50 % + 40 μA 0.70 % + 150 μA 0.47 % rdg + 0.020 % rng 0.19 % + 200 μA 0.10 % + 200 μA 0.13 % rdg + 0.020 % rng 0.12 % rdg + 0.020 % rng 1.2 % + 40 μA Agilent 3458A opt 002 AC Current – Generate3 (0.029 to 0.329 99) mA (0.33 to 3.2999) mA (3.3 to 32.999) mA (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 0.29 % rdg + 0.15 μA 0.15 % rdg + 0.15 μA 0.15 % rdg + 0.25 μA 0.47 % rdg + 0.15 μA 0.29 % rdg + 0.15 μA 0.24 % rdg + 0.3 μA 0.12 % rdg + 0.3 μA 0.12 % rdg + 0.3 μA 0.24 % rdg + 0.3 μA 0.70 % rdg + 0.3μA 0.24 % rdg + 0.03 mA 0.12 % rdg + 0.03 mA 0.11 % rdg + 0.03 mA 0.24 % rdg + 0.03 mA 0.70 % rdg + 0.03 mA Fluke 5500A
1 to 10 kV
11--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1387.04) Revised 3/5/2025 Page 11 of 16 Parameter/Range Frequency CMC2, 7 (±) Comments AC Current – Generate3 (cont) (33 to 329.99) mA (0.33 to 2.19999) A (2.2 to 11) A (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (45 to 65) Hz (65 to 500) Hz 500 Hz to 1 kHz 0.24 % rdg + 0.03 mA 0.12 % rdg + 0.03 mA 0.11 % rdg + 0.03 mA 0.24 % rdg + 0.03 mA 0.70 % rdg + 0.03 mA 0.24 % rdg + 0.3 A 0.12 % rdg + 0.3 A 0.87 % rdg + 0.3 A 0.070 % rdg + 0.002 A 0.12 % rdg + 0.002 A 0.38 % rdg + 0.002 A Fluke 5500A Parameter/Equipment Range CMC2, 7 (±) Comments Resistance – Generate3 (0 to 10.999) Ω (11 to 32.999) Ω (33 to 109.999) Ω (110 to 329.999) Ω (0.330 to 1.099 99) kΩ (1.1 to 3.299 99) kΩ (3.3 to 10.9999) kΩ (11 to 32.9999) kΩ (33 to 109.999) kΩ (110 to 329.999) kΩ (0.33 to 1.099 99) MΩ (1.1 to 3.299 99) MΩ (3.3 to 10.9999) MΩ (11 to 32.9999) MΩ (33 to 109.999) MΩ 0.014 % + 93 mΩ 0.014 % + 17 mΩ 0.14 % + 17 mΩ 0.11 % + 17 mΩ 0.12 % + 66 mΩ 0.46 % + 55 mΩ 0.12 % + 660 mΩ 0.11 % + 690 mΩ 0.13 % + 6.9 Ω 0.15 % + 6.7 Ω 0.16 % + 87 Ω 0.20 % + 50 Ω 0.70 % + 650 Ω 1.4 % + 550 Ω 5.8 % + 6.5 kΩ Fluke 5500A, 4- wire Fluke 5500A, 2- wire Resistance – Measure3 (0 to 10) Ω (10 to 100) Ω 100 Ω to 1 kΩ (1 to 100) kΩ 100 kΩ to 1 MΩ (1 to 10) MΩ (10 to 100) MΩ 15 µΩ/Ω + 5 µΩ 15 µΩ/Ω + 50 µΩ 19 µΩ/Ω + 50 µΩ 52 µΩ/Ω + 50 mΩ 50 µΩ/Ω + 60 µΩ 50 µΩ/Ω + 150 µΩ 0.070 % + 5.0 kΩ Agilent 3458A opt 002
to 109.999 MΩ
12--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1387.04) Revised 3/5/2025 Page 12 of 16 Parameter/Equipment Range CMC2, 7 (±) Comments Capacitance – Generate3 (0.33 to 0.499) nF (0.5 to 1.0999) nF (1.1 to 3.2999) nF (3.3 to 10.999) nF (11 to 32.999) nF (33 to 109.99) nF (110 to 329.99) nF (0.33 to 1.0999) µF (1.1 to 3.2999) µF (3.3 to 10.999) µF (11 to 32.999) µF (33 to 109.99) µF (110 to 329.99) µF 330 µF to 1.1 mF 0.58 % + 0.012 nF 0.58 % + 0.012 nF 0.61 % + 0.011 nF 0.58 % + 0.012 nF 0.33 % + 0.11 nF 0.29 % + 0.13 nF 0.56 % + 1.2 nF 0.29 % + 1.2 nF 0.41 % + 3.5 nF 0.41 % + 12 nF 0.47 % + 35 nF 0.58 % + 120 nF 0.94 % + 350 nF 1.2 % + 350 nF Fluke 5500A Electrical Calibration of Thermocouples & Thermocouple Indicating Systems3 – Type B Type C Type E (600 to 800) °C (800 to 1000) °C (1000 to 1550) °C (1550 to 1820) °C (0 to 150) °C (150 to 650) °C (650 to 1000) °C (1000 to 1800) °C (1800 to 2316) °C (-250 to -100) °C (-100 to -25) °C (-25 to 350) °C (350 to 650) °C (650 to 1000) °C 0.59 °C 0.45 °C 0.39 °C 0.39 °C 0.37 °C 0.32 °C 0.38 °C 0.59 °C 0.97 °C 0.57 °C 0.19 °C 0.16 °C 0.18 °C 0.24 °C Fluke 5500A
0.33 to 1.1 mF
13

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1387.04) Revised 3/5/2025 Page 13 of 16 Parameter/Equipment Range CMC2 (±) Comments Electrical Calibration of Thermocouples & Thermocouple Indicating Systems3 – (cont) Type J Type K Type L Type N Type R Type S Type T Type U (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 1000) °C (1000 to 1372) °C (-200 to -100) °C (-100 to 800) °C (800 to 900) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 410) °C (410 to 1300) °C (0 to 250) °C (250 to 400) °C (400 to 1000) °C (1000 to 1767) °C (0 to 250) °C (250 to 1000) °C (1000 to 1400) °C (1400 to 1767) °C (-250 to -150) °C (-150 to 0) °C (0 to 120) °C (120 to 400) °C (-200 to 0) °C (0 to 600) °C 0.31 °C 0.19 °C 0.16 °C 0.20 °C 0.27 °C 0.37 °C 0.21 °C 0.19 °C 0.30 °C 0.46 °C 0.43 °C 0.30 °C 0.20 °C 0.45 °C 0.27 °C 0.22 °C 0.21 °C 0.31 °C 0.70 °C 0.43 °C 0.40 °C 0.43 °C 0.58 °C 0.44 °C 0.44 °C 0.51 °C 0.70 °C 0.28 °C 0.19 °C 0.16 °C 0.65 °C 0.31 °C Fluke 5500A
14

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1387.04) Revised 3/5/2025 Page 14 of 16 Parameter/Equipment Range CMC2 (±) Comments Electrical Calibration of RTD Indicating Systems3 – Pt 395, 100 Ω Pt 3926, 100 Ω Pt 3916, 100 Ω Pt 385, 200 Ω Pt 385, 500 Ω (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (630 to 800) °C (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (-200 to -190) °C (-190 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C 0.060 °C 0.060 °C 0.090 °C 0.11 °C 0.12 °C 0.14 °C 0.26 °C 0.060 °C 0.060 °C 0.090 °C 0.10 °C 0.12 °C 0.14 °C 0.29 °C 0.050 °C 0.060 °C 0.070 °C 0.090 °C 0.090 °C 0.10 °C 0.12 °C 0.26 °C 0.050 °C 0.050 °C 0.050 °C 0.060 °C 0.15 °C 0.17 °C 0.18 °C 0.19 °C 0.050 °C 0.070 °C 0.070 °C 0.080 °C 0.10 °C 0.10 °C 0.10 °C 0.12 °C Fluke 5500A
15

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1387.04) Revised 3/5/2025 Page 15 of 16 Parameter/Equipment Range CMC2 (±) Comments Electrical Calibration of RTD Indicating Systems3 (cont) – Pt 385, 1000 Ω PtNi 385, 120 Ω (Nil20) Cu 427, 10 Ω (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (260 to 300) °C (300 to 400) °C (400 to 600) °C (600 to 630) °C (-80 to 0) °C (0 to 100) °C (100 to 260) °C (-100 to 260) °C 0.040 °C 0.040 °C 0.050 °C 0.070 °C 0.070 °C 0.090 °C 0.090 °C 0.27 °C 0.10 °C 0.10 °C 0.17 °C 0.35 °C Fluke 5500A IV. Mechanical Parameter/Equipment Range CMC2, 6, 8 (±) Comments Torque Wrenches3 (4 to 40) oz-in (4 to 50) lbf-in (30 to 400) lbf-in (80 to 1000) lbf-in 20 to 250 lbf-ft 60 to 600 lbf-ft 0.23 % + 0.28 oz-inf 0.28 % + 0.083 lbf-in 0.4 % + 0.28 lbf-in 0.44 % + 0.55 lbf-in 0.46 % + 0.39 lbf-ft 0.28 % + 0.76 lbf-ft Torque transducers V. Time & Frequency Parameter/Equipment Range CMC2, 6, 8 (±) Comments Stop Watches/Time Measurement3 Up to 24 hours 0.12 s Quartz watch-clock analyzer Frequency – Measure Up to 10 MHz 2.6 Hz Agilent 3458A ________________________________________________________________
16

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1387.04) Revised 3/5/2025 Page 16 of 16 1 This laboratory offers commercial dimensional testing/calibration and on-site calibration services. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the Calibration and Measurement Capability Uncertainty (CMC) found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches or millimeters. DL is the diagonal length in inches or millimeters. R is the resolution of the unit under test. D is the numerical value of the nominal diameter of the device measured in inches or millimeters. Pitch diameter is measured by the three-wire method. Major diameter is calibrated by direct measurement. In the statement of CMC, T indicates temperature in degrees Celsius. In the statement of CMC, H is the Humidity of the reading. 5 This laboratory meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program for the types of dimensional tests listed above and is considered equivalent to that of a calibration. 6 In the statement of CMC, a percent refers to a percentage of reading unless otherwise noted and IV stands for indicated value. 7 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 8 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 9 This scope meets A2LA’s P112 Flexible Scope Policy.
17ISO/IEC 17025:2017; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

7044 Fairfield Business Center, Fairfield, OH, 45014, US

39.78861, -82.64189

Open in Maps

Other Locations

2 other sites in this organization

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.