Hong Kong SAR China

CAL LAB LIMITED

Room 2103, Technology Plaza 29-35 Sha Tsui Road, Tsuen Wan, NT, Hong Kong, Tsuen Wan, NT, Hong Kong SAR China

Visit website
A2LA 3815.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
3
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 3 standard numbers and the 2 official names we hold. When no standard matches, it searches the method text of every scope line.

IEC 60079-29-2
ISO 8655-6Piston-operated volumetric apparatus - Part 6: Gravimetric reference measurement procedure for the determination of volume
ISO 21501-4Determination of particle size distribution - Single particle light interaction methods - Part 4: Light scattering airborne particle counter for clean spaces

Read from the A2LA scope document we downloaded on 2025-12-02. Register refreshed 2026-11-20.

Scope as published by A2LA

6 lines
A2LA

ISO/IEC 17025

Active

3815.01

The scope document we hold says it is valid until 2027-09-30.

View scope

Accredited scope, certificate 3815.01

LineMethodMatrixRange
1ISO/IEC 17025:2017 CAL LAB LIMITED Room 2103; Isobutylene Hydrogen Sulfide Methane Up to 500 µmol/mol Up to 5000 µmol/mol Up to 10 µmol/mol Up to 100 µmol/mol Up to 5; ison BS EN 60079-29-2/ JJG 635/ JJG915 Reference gas comparison BS EN 60079-29-2/ JJG 635 Reference gas comparison BS EN 60079-29-2/ JJF 1172 Reference gas comparison BS EN 60079-29-2/ JJG 695 Reference gas comparison BS EN 60079-29-2/ JJG 693; IEC 17025-See scope document
2ison BS EN 60079-29-2/ JJG 365 Reference gas comparison BS EN 60079-29-2 Reference gas comparison BS EN 60079-29-2/ JJG 1077 Reference gas comparison BS EN 60079-29-2/ JJG 551 Reference gas comparison BS EN 60079-29-2/ JJG 1022 Reference meter comparison JJG 825 Reference meter comparison ISO 21501-4/ JJF 1659/ JJG 846-See scope document
3--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3815.01) 11/26/2025 Page 3 of 5 Parameter/Equipment Range CMC2, 3, 5 (±) Comments DC Resistance – Measure 0.1 Ω to 100 MΩ 0.055 % Keysight 34461A DC Current – Generate Clamp meters (0.0001 to 20) A Up to 1000 A 0.20 % 1.0 % Multifunction calibrator Multifunction calibrator with 50-turn coil DC Voltage – Generate (0.01 to 1000) V 0.11 % Multifunction calibrator DC Resistance – Generate Fixed Points 1 mΩ 10 mΩ 100 mΩ 1 Ω 10 Ω 100 Ω 1 kΩ 10 kΩ 100 kΩ 1 MΩ 10 MΩ 0.26 % 0.26 % 0.26 % 0.26 % 0.26 % 0.26 % 0.26 % 0.26 % 0.26 % 0.26 % 0.26 % Reference resistors Parameter/Equipment Frequency CMC2, 4, 5 (±) Comments AC Current – Measure (0.0001 to 10) A (10 to 20) A 60 Hz 60 Hz 0.65 % 0.80 % Keysight 34461A UNI-T UT89X AC Voltage – Measure (0.25 to 750) V (750 to 1000) V 60 Hz 0.21 % 0.60 % Keysight 34461A UNI-T UT89X AC Current – Generate (0.002 to 20) A Clamp Meters, All types - Up to 1000 60 Hz 60 Hz 0.65 % 1.0 % Multifunction calibrator Multifunction calibrator with 50-turn coil
0.1 to 100000000 Ω
4ison JJG 956; ISO 8655-6Air; air; electronicSee scope document
5JJF 1076-See scope document
6ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.