Aldinger Company dba Servo Innovations

Wayland, MI, United States

Visit website
A2LA 2444.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
5
A2LA certificate
1
Sites in our directory
2
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 5 scope lines.

A2LA certificate 2444.01 · 5 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017-to 12 in
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 2444.01) 03/19/2025 Page 2 of 4 III. Fluid Quantities Parameter/Equipment Range CMC2, 4 (±) Comments Liquid Flow Meters3 (5 to 50) gpm 0.38 % Reference flowmeter IV. Mechanical Parameter/Range Frequency CMC2, 4 (±) Comments Accelerometers- Sensitivity Magnitude 3 (1-10 000) mV/g (10 to 20) Hz (>20 to 100) Hz >100 Hz to 2.5 kHz (>2.5 to 5) kHz 4.3 % 4.2 % 4.2 % 5 % Reference accelerometer, DAQ Parameter/Equipment Range CMC2, 4 (±) Comments Force Devices3 – Force – Compression (0.0010 to 20) lbf Up to 112 lbf Up to 500 lbf Up to 2000 lbf Up to 5000 lbf (5000 to 10 000) lbf (10 000 to 20 000) lbf (20 000 to 50 000) lbf (50 000 to 100 000) lbf (100 000 to 200 000) lbf (200 000 to 400 000) lbf (200 000 to 600 000) lbf 0.11 % 0.018 % 0.09 % 0.029 % 0.043 % 0.069 % 0.19 % 0.05 % 0.13 % 0.11 % 0.17 % 0.22 % Calibrated items include, but not limited to, load cells, hydraulic actuators, tensile testers and dynamometers Mass standards, precision load cells
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 2444.01) 03/19/2025 Page 3 of 4 Parameter/Equipment Range CMC2, 4 (±) Comments Force Devices3 (cont.) – Force – Tension Torque Displacement Angle Speed Velocity Pressure Up to 110 lbf Up to 500 lbf Up to 2000 lbf Up to 5000 lbf (5000 to 10 000) lbf (5000 to 20 000) lbf (20 000 to 50 000) lbf (50 000 to 100 000) lbf (100 000 to 200 000) lbf (200 000 to 400 000) lbf Up to 500 lbf·in Up to 1000 lbf·in (500 to 20 000) lbf·in (20 000 to 100 000) lbf·in (100 000 to 300 000) lbf·in (300 000 to 1 200 000) lbf·in UP to 40 in (0 to 360) ° (6 to 8299) rpm (8299 to 24 999) rpm (25 000 to 99 000) rpm Up to 2 in/s (2 to 600) in/s Up to 300 psi (300 to 1500) psi (1500 to 10 000) psi 0.013 % 0.09 % 0.057 % 0.094 % 0.069 % 0.10 % 0.09 % 0.09 % 0.16 % 0.26 % 0.11 % 0.099 % 0.08 % 0.25 % 0.048 % 0.072 % 0.005 in 0.28° 3.1 rpm 6.9 rpm 15 rpm 0.22 in/s 0.035 in/s 0.13 % 0.11 % 0.12 % Calibrated items include, but not limited to, load cells, hydraulic actuators, tensile testers and dynamometers Mass standards, precision load cells Torque arms, mass standards and precision load cells LVDT w/Indicator Rotary encoder Tachometer Stopwatch LVDT w/datalogger Reference pressure gauges
4--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 2444.01) 03/19/2025 Page 4 of 4 V. Thermodynamics Parameter/Equipment Range CMC2 (±) Comments Temperature3 – Thermocouple Simulation B, E, J, K, N, R, S, T (-10 to 122) °C 0.42 °C Thermoelectric calibrator Temperature Probe3 (-10 to 110) °C 0.42 °C Drywell __________________________________________________ 1 This laboratory offers commercial calibration service and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, % is defined as the percentage of full scale unless otherwise noted. 5 Fluke This scope meets A2LA’s P112 Flexible Scope Policy. 6 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as eit her a specific value that covers the full range or as a fraction/percentage of the reading plus a fixed floor specification.
-10 to 122 °C
5ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Other Locations

1 other site in this organization

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.