Aldinger Company dba Servo Innovations
Wayland, MI, United States
Visit website- Scope lines
- 5
- A2LA certificate
- 1
- Sites in our directory
- 2
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 5 scope lines.
A2LA certificate 2444.01 · 5 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017 | - | to 12 in |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert No. 2444.01) 03/19/2025 Page 2 of 4
III. Fluid Quantities
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Liquid Flow Meters3
(5 to 50) gpm
0.38 %
Reference flowmeter
IV. Mechanical
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
Accelerometers-
Sensitivity Magnitude
3
(1-10 000) mV/g
(10 to 20) Hz
(>20 to 100) Hz
>100 Hz to 2.5 kHz
(>2.5 to 5) kHz
4.3 %
4.2 %
4.2 %
5 %
Reference accelerometer,
DAQ
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Force Devices3 –
Force – Compression
(0.0010 to 20) lbf
Up to 112 lbf
Up to 500 lbf
Up to 2000 lbf
Up to 5000 lbf
(5000 to 10 000) lbf
(10 000 to 20 000) lbf
(20 000 to 50 000) lbf
(50 000 to 100 000) lbf
(100 000 to 200 000) lbf
(200 000 to 400 000) lbf
(200 000 to 600 000) lbf
0.11 %
0.018 %
0.09 %
0.029 %
0.043 %
0.069 %
0.19 %
0.05 %
0.13 %
0.11 %
0.17 %
0.22 %
Calibrated items include, but
not limited to, load cells,
hydraulic actuators, tensile
testers and dynamometers
Mass standards, precision
load cells | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert No. 2444.01) 03/19/2025 Page 3 of 4
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Force Devices3 (cont.) –
Force – Tension
Torque
Displacement
Angle
Speed
Velocity
Pressure
Up to 110 lbf
Up to 500 lbf
Up to 2000 lbf
Up to 5000 lbf
(5000 to 10 000) lbf
(5000 to 20 000) lbf
(20 000 to 50 000) lbf
(50 000 to 100 000) lbf
(100 000 to 200 000) lbf
(200 000 to 400 000) lbf
Up to 500 lbf·in
Up to 1000 lbf·in
(500 to 20 000) lbf·in
(20 000 to 100 000) lbf·in
(100 000 to 300 000) lbf·in
(300 000 to 1 200 000) lbf·in
UP to 40 in
(0 to 360) °
(6 to 8299) rpm
(8299 to 24 999) rpm
(25 000 to 99 000) rpm
Up to 2 in/s
(2 to 600) in/s
Up to 300 psi
(300 to 1500) psi
(1500 to 10 000) psi
0.013 %
0.09 %
0.057 %
0.094 %
0.069 %
0.10 %
0.09 %
0.09 %
0.16 %
0.26 %
0.11 %
0.099 %
0.08 %
0.25 %
0.048 %
0.072 %
0.005 in
0.28°
3.1 rpm
6.9 rpm
15 rpm
0.22 in/s
0.035 in/s
0.13 %
0.11 %
0.12 %
Calibrated items include,
but not limited to, load
cells, hydraulic
actuators, tensile testers
and dynamometers
Mass standards,
precision load cells
Torque arms, mass
standards and precision
load cells
LVDT w/Indicator
Rotary encoder
Tachometer
Stopwatch
LVDT w/datalogger
Reference pressure
gauges | ||
| 4 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert No. 2444.01) 03/19/2025 Page 4 of 4
V. Thermodynamics
Parameter/Equipment
Range
CMC2 (±)
Comments
Temperature3 –
Thermocouple Simulation
B, E, J, K, N, R, S, T
(-10 to 122) °C
0.42 °C
Thermoelectric
calibrator
Temperature Probe3
(-10 to 110) °C
0.42 °C
Drywell
__________________________________________________
1 This laboratory offers commercial calibration service and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 In the statement of CMC, % is defined as the percentage of full scale unless otherwise noted.
5 Fluke This scope meets A2LA’s P112 Flexible Scope Policy.
6 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMCs are expressed as eit her a specific value that covers the full range or as a
fraction/percentage of the reading plus a fixed floor specification. | -10 to 122 °C |
| 5 | ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.