What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 1 standard number and the 1 official name we hold. When no standard matches, it searches the method text of every scope line.
ASTM E18Standard Test Methods for Rockwell Hardness of Metallic Materials
ASTM E18
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
5 lines
ISO/IEC 17025
Active2290.01
The scope document we hold says it is valid until 2027-03-31.
Accredited scope, certificate 2290.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | to 36 in |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2290.01) 08/18/2025 Page 2 of 4
Parameter/Equipment Range CMC2, 4 (±) Comments
Optical Comparators3 –
Magnification
Travel
Squareness
Angle
10× to 50×
(4 to 12) in
Up to 3 in
0° to 360°
140 µin
71 μin
120 μin
1.1 minutes
Glass scale, gage blocks
Protractors3
Up to 360°
13 minutes or 0.22°
angular
Angle blocks
Pin Gages3
Up to 1 in
7.8 μin
P&W SupermicrometerTM,
gage blocks
Master Plug Gages3
Up to 6 in
(8.6 + 2.8L) μin
P&W SupermicrometerTM,
gage blocks
Plain Ring Gages
(0.04 to 10) in
(8.6 + 2.8L) μin
Internal comparator, gage
blocks
Profilometers3 – Indirect
Verification of Ra
Measurement
120 μin @
0.03 in cut-off
2.0 Ra
Master specimens
Square and Angle Plates
Up to 15 in
57 μin
Cylindrical square
Surface Plates3 –
Flatness
Repeat Reading
(6 × 6) in to
(72 × 144) in
Up to 0.002 in
(30 + 10A) μin
28 µin
Autocollimator
Repeat-o-meter
Thread Wires
(4 to 80) pitch
8.2 μin
Measuring machine,
gage blocks | 4 to 80 pitch |
| 3 | 3-wire method | - | See scope document |
| 4 | ASTM E18 | - | - |
| 5 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Technical Maintenance, Inc. - ROCKFORDRockford, IL · ~451 kmA2LAShares 2 accredited test methodsANSI/NCSL Z540-1-1994ASTM E18
- Quality Calibration ServiceNew Berlin, WI · ~466 kmA2LAShares 2 accredited test methodsANSI/NCSL Z540-1-1994ASTM E18
- Trescal, Inc - Milwaukee, WIMilwaukee, WI · ~477 kmA2LAShares 2 accredited test methodsANSI/NCSL Z540-1-1994ASTM E18
- Mitutoyo America CorporationAurora, IL · ~530 kmA2LAShares 2 accredited test methodsANSI/NCSL Z540-1-1994ASTM E18
- International Certification Measurements, Inc. (subsidiary of Leader Corporation)Shelby Township, MI · ~573 kmA2LAShares 2 accredited test methodsANSI/NCSL Z540-1-1994ASTM E18
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.