SAFETECH CALIBRATION LAB - A DIVISION OF SAFETY INTERNATIONAL GENERAL TRADING AND CONTRACTING CO. W.L.L.

Safety International Building, block 9 Plot 15, Shuaiba Industrial Area (West), Shuaiba, Kuwait, Shuaiba, Kuwait

Visit website
A2LA 5265.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
14
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 14 scope lines.

A2LA certificate 5265.01 · 14 lines

LineMethodMatrixRange
1--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5265.01) 10/13/2025 Page 1 of 13 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 SAFETECH CALIBRATION LAB – A DIVISION OF SAFETY INTERNATIONAL GENERAL TRADING AND CONTRACTING CO. W.L.L. Safety International Building, Block 9 Plot 15 Shuaiba Industrial Area (West) KUWAIT Suraj James Phone: 00965 97285098 CALIBRATION Valid to: March 31, 2027 Certificate Number: 5265.01 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 6: I. Chemical Parameter/Equipment Range CMC2, 3 (±) Comments Conductivity Meters 100 µS/cm 1413 µS/cm 3.3 µS/cm 16 µS/cm Standard conductivity solution pH Meters 4 pH 7 pH 10 pH 0.02 pH 0.02 pH 0.02 pH Standard buffer solution II. Dimensional Parameter/Equipment Range CMC 2 (±) Comments Calipers Up to 250 mm 0.01 mm Resolution 0.02 mm Resolution 5.8 µm 12 µm Gage block set (Grade 0) Micrometers Up to 25 mm Up to 100 mm 0.61 µm 5.8 µm Gage block set (Grade 0)
to 250 mm
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5265.01) 10/13/2025 Page 2 of 13 Parameter/Equipment Range CMC2 (±) Comments Coating Thickness Gauge Up to 1500 µm 2.8 µm Standard foil set & micrometer Feeler Gauge (0.04 to 1.00) µm 1.8 µm Digital micrometer Dial Indicator Up to 25 mm 6.5 µm Calibration tester / indicator calibrator Dial Thickness Gauge Up to 25 mm 1.0 µm Gauge blocks III. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 4 (±) Comments DC Voltage – Generate (0 to 330) mV (0 to 3.3) V (0 to 33) V (30 to 330) V (100 to 1000) V 20 µV/V + 1 µV 10 µV/V + 7 µV 10 µV/V + 60 µV 20 µV/V + 0.4 mV 20 µV/V + 1.6 mV Fluke-5522A DC Voltage – Measure (0 to 200) mV 200 mV to 2 V (2 to 20) V (20 to 200) V (200 to 1000) V 6 µV/V + 0.1 µV 2 µV/V + 2 µV 3 µV/V + 10 µV 4 µV/V + 100 µV 5 µV/V + 200 µV 8.5-digit Multimeter (Fluke-8508A) DC High Voltage – Measure (2 to 40) kV 0.87 kV HV probe Fluke 80k-40
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5265.01) 10/13/2025 Page 3 of 13 Parameter/Equipment Range CMC2, 4 (±) Comments DC Current – Generate Clamp-On Meters (0 to 330) µA (0 to 3.3) mA (0 to 33) mA (0 to 330) mA (0 to 1.1) A (1.1 to 3) A (0 to 11) A (11 to 20.5) A Up to 10 A Up to 500 A Up to 1000 A 100 µA/A + 20 nA 90 µA/A + 90 nA 100 µA/A + 300 nA 100 µA/A + 3 µA 200 µA/A + 90 µA 400 µA/A + 40 µA 500 µA/A + 500 µA 1.4 mA/A + 9 mA 250 µA/A + 85 mA 3.5 mA/A + 0.5 A 3.6 mA/A + 0.8 A Fluke-5522A Fluke-5522 with 50 turn coil DC Current – Measure (0 to 200) µA 200 µA to 2 mA (2 to 20) mA (20 to 200) mA 200 mA to 2 A (2 to 20) A 10 µA/A + 0.7 nA 10 µA/A + 7 nA 10 µA/A + 70 nA 30 µA/A + 1 µA 200 µA/A + 20 µA 400 µA/A + 0.4 mA 8.5-digit Multimeter Capacitance – Generate (0.220 to 0.6) nF (0.6 to 1) nF (1 to 11) nF (11 to 110) nF 110 nF to 1.1 µF (1.1 to 11) µF (11 to 110) µF 110 µF to 1.1 mF (1.1 to 11) mF (11 to 100) mF 2.1 mF/F + 10 pF 4.5 mF/F + 10 pF 2.3 mF/F + 10 pF 3.5 mF/F + 0.2 pF 3.5 mF/F 3.5 mF/F 5.8 mF/F + 30nF 5.4 mF/F + 20 nF 5.5 mF/F + 20 nF 13 mF/F + 80 µF Fluke-5522A
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5265.01) 10/13/2025 Page 4 of 13 Parameter/Equipment Range CMC2, 4 (±) Comments Resistance – Generate (0 to 11) Ω (11 to 33) Ω (33 to 110) Ω (110 to 330) Ω 330Ω to 1.1 kΩ (1.1 to 3.3) kΩ (3.3 to 11) kΩ (11 to 33) kΩ (33 to 110) kΩ (110 to 330) kΩ 330 kΩ to 1.1 MΩ (1.1 to 3.3) MΩ (3.3 to 11) MΩ (11 to 33) MΩ (33 to 110) MΩ (110 to 330) MΩ (330 to 1100) MΩ 40 µΩ/Ω + 1 mΩ 30 µΩ/Ω + 1.1 mΩ 20 µΩ/Ω + 1.3 mΩ 30 µΩ/Ω + 1.2 mΩ 40 µΩ/Ω + 4.3 mΩ 20 µΩ/Ω + 15 mΩ 20 µΩ/Ω + 23 mΩ 30 µΩ/Ω + 76 mΩ 30 µΩ/Ω + 77 mΩ 30 µΩ/Ω + 0.8 Ω 30 µΩ/Ω + 2 Ω 20 µΩ/Ω + 160 Ω 600 µΩ/Ω + 1.5 kΩ 700 µΩ/Ω + 6 kΩ 700 µΩ/Ω + 14 kΩ 18 mΩ/Ω + 2 MΩ 6.9 mΩ/Ω + 3 MΩ Fluke-5522A Resistance – Measure (0 to 2) Ω (2 to 20) Ω (20 to 200) Ω (200 to 2) kΩ (2 to 20) kΩ (20 to 200) kΩ 200 kΩ to 2 MΩ (2 to 20) MΩ (20 to 200) MΩ 200 MΩ to 2 GΩ 3 µΩ/Ω + 60 µΩ 6 µΩ/Ω + 60 µΩ 7 µΩ/Ω + 0.1 mΩ 0.6 µΩ/Ω + 14 mΩ 8 µΩ/Ω + 15 mΩ 8 µΩ/Ω + 0.11 Ω 10 µΩ/Ω + 1.2 Ω 20 µΩ/Ω + 100 Ω 80 µΩ/Ω + 10 kΩ 500 µΩ/Ω + 1 MΩ 8.5-digit Multimeter (Fluke-8508A) Insulation Resistance – Generate (Up to 1 kV) Up to 1 MΩ (1 to 10) MΩ (10 to100) MΩ 100 MΩ to 1 GΩ (1 to 10) GΩ (10 to 20) GΩ (20 to 40) GΩ (40 to 60) GΩ (60 to 80) GΩ (80 to100) GΩ 0.8 kΩ 0.011 MΩ 0.79 MΩ 0.95 MΩ 0.039 GΩ 0.16 GΩ 0.62 GΩ 1.6 GΩ 2.6 GΩ 3.9 GΩ Insulation tester calibrator time electronics 5069
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5265.01) 10/13/2025 Page 5 of 13 Parameter/Equipment Range CMC2, 4 (±) Comments Insulation Resistance – Generate (cont) (Up to 10 kV) 100 MΩ to 1 GΩ (1 to 10) GΩ (10 to 20) GΩ (20 to 40) GΩ (40 to 60) GΩ (60 to 80) GΩ (80 to100) GΩ 0.95 MΩ 0.039 GΩ 0.16 GΩ 0.62 GΩ 1.6 GΩ 2.6 GΩ 3.9 GΩ Insulation tester calibrator time electronics 5069 Electrical Simulation of Temperature Instruments – Generate Pt 100 Type B Type C Type E Type J Type K Type L Type N Type R Type S Type T Type U (-200 to 0) °C (0 to 800) °C (600 to 1800) °C (0 to 2300) °C (-250 to 1000) °C (-200 to 1200) °C (-200 to 1350) °C (-200 to 900) °C (-200 to 1300) °C (0 to 1700) °C (0 to 1700) °C (-250 to 400) °C (-200 to 600) °C 0.0001 °C/°C + 0.07 °C 0.0002 °C/°C + 0.07 °C 0.45 °C 0.85 °C 0.51 °C 0.29 °C 0.42 °C 0.39 °C 0.42 °C 0.58 °C 0.48 °C 0.64 °C 0.57 °C Fluke-5522A Electrical Simulation of Temperature Instruments – Measure Pt 100 Type B Type C Type E Type J Type K Type L Type N Type R Type S Type T Type U (-200 to 0) °C (0 to 800) °C (600 to 1800) °C (0 to 2300) °C (-250 to 1000) °C (-200 to 1200) °C (-200 to 1350) °C (-200 to 900) °C (-200 to 1300) °C (0 to 1700) °C (0 to 1700) °C (0 to 400) °C (-200 to 600) °C 0.1 °C 0.24 °C 0.47 °C 0.86 °C 0.53 °C 0.32 °C 0.43 °C 0.41 °C 0.43 °C 0.59 °C 0.50 °C 0.65 °C 0.59 °C Fluke-5522A & 8.5- digital multimeter (Fluke-8508A) Fluke-5522A
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5265.01) 10/13/2025 Page 6 of 13 Parameter/Equipment Range CMC2, 4 (±) Comments AC Voltage – Generate (3 to 33) mV (33 to 330) mV (0.33 to 3.3) V (3.3 to 33) V (33 to 330) V (330 to 1020) V 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 450) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 450) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 90) kHz 45 Hz to 1 kHz (1 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 5) kHz (5 to 8) kHz 0.5 mV/V + 6 µV 0.6 mV/V + 6 µV 0.9 mV/V + 6 µV 1.8 mV/V + 9 µV 5.6 mV/V + 20 µV 0.2 mV/V + 30 µV 0.2 mV/V + 20 µV 0.1 mV/V + 20 µV 0.2 mV/V + 30 µV 0.1 mV/V + 70 µV 0.1 mV/V + 90 µV 0.2 mV/V + 100 µV 0.2 mV/V + 200 µV 0.2 mV/V + 200 µV 0.3 mV/V + 300 µV 0.5 mV/V + 700 µV 1.4 mV/V + 0.3 mV 0.1 mV/V + 400 µV 0.1 mV/V + 200 µV 0.2 mV/V + 30 µV 0.3 mV/V + 0.2 mV 0.5 mV/V + 0.4 mV 0.1 mV/V + 0.4 mV 0.2 mV/V + 0.8 mV 0.2 mV/V + 0.6 mV 0.2 mV/V + 0.9 mV 0.7 mV/V + 7.0 mV 0.3 mV/V + 66 mV 0.3 mV/V + 62 mV 0.4 mV/V + 68 mV Fluke-5522A
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5265.01) 10/13/2025 Page 7 of 13 Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage – Measure (100 to 200) mV 200 mV to 2 V (2 to 20) V (20 to 200) V (20 to 55) Hz (55 to 305) Hz 305 Hz to 1kHz (1 to 3) kHz (3 to 10) kHz (10 to 30) kHz (30 to 60) kHz (60 to 100) kHz (20 to 55) Hz (55 to 305) Hz 305 Hz to 1kHz (1 to 3) kHz (3 to 10) kHz (10 to 30) kHz (30 to 60) kHz (60 to 100) kHz (100 to 500) kHz 500 kHz to 1 MHz (20 to 55) Hz (55 to 305) Hz 305 Hz to 1kHz (1 to 3) kHz (3 to 10) kHz (10 to 30) kHz (30 to 60) kHz (60 to 100) kHz (100 to 500) kHz 500 kHz to 1 MHz 0.1 mV/V + 6 µV 0.1 mV/V + 5 µV 0.1 mV/V + 3 µV 0.1 mV/V + 3 µV 0.1 mV/V + 4 µV 0.2 mV/V + 7 µV 0.5 mV/V + 10 µV 0.7 mV/V + 20 µV 100 µV/V + 6 µV 80 µV/V + 7 µV 70 µV/V + 8 µV 90 µV/V + 6 µV 100 µV/V + 5 µV 200 µV/V + 10 µV 400 µV/V + 20 µV 700 µV/V + 30 µV 19 mV/V + 3.6 mV 30 mV/V 80 µV/V + 60 µV 50 µV/V + 10 µV 40 µV/V + 10 µV 90 µV/V + 70 µV 100 µV/V + 10 µV 200 µV/V + 60 µV 500 µV/V 700 µV/V 15 mV/V 30 mV/V Fluke-8508A
8--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5265.01) 10/13/2025 Page 8 of 13 Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage – Measure (cont.) (200 to 1000) V (55 to 305) Hz 305 Hz to 1kHz (1 to 3) kHz (3 to 10) kHz (10 to 30) kHz 100 µV/V + 17 mV 100 µV/V + 13 mV 100 µV/V + 15 mV 100 µV/V + 15 mV 200 µV/V + 40 mV Fluke-8508A AC High Voltage – Measure (2 to 28) kV 50 Hz 1.6 kV HV Probe (Fluke 80k-40) AC Current – Generate (29 to 330) µA (0.33 to 3.3) mA (3.3 to 33) mA (33 to 330) mA (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz 1.7 mA/A + 100 nA 1.4 mA/A + 100 nA 2.1 mA/A + 100 nA 5.5 mA/A + 200 nA 12 mA/A + 300 nA 16 mA/A + 400 nA 1.6 mA/A + 200 nA 1.0 mA/A + 200 nA 0.8 mA/A + 200 nA 1.2 mA/A + 400 nA 2.6 mA/A + 800 nA 5.6 mA/A + 2 µA 1.5 mA/A + 300 nA 0.4 mA/A + 2 µA 0.4 mA/A + 1 µA 0.5 mA/A + 2 µA 1.1 mA/A + 6 µA 2.1 mA/A + 10 µA 1.6 mA/A 0.8 mA/A + 7 µA 0.4 mA/A + 5 µA 2.1 mA/A + 100 µA 1.4 mA/A + 2 µA 2.9 mA/A + 10 µA Fluke-5522A
200 to 1000 V
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5265.01) 10/13/2025 Page 9 of 13 Parameter/Range Frequency CMC2, 4 (±) Comments AC Current – Generate (cont.) (0.33 to 1.1) A (1.1 to 3) A (3 to 11) A (11 to 20.5) A (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (45 to 100) Hz 100 Hz to 1 kHz (1 to 5) kHz (45 to 100) Hz 100 Hz to 1 kHz (1 to 5) kHz 1.1 mA/A + 20 µA 0.5 mA/A + 10 µA 4.2 mA/A + 1.2 mA 8.0 mA/A + 2.3 mA 1.1 mA/A + 70 µA 0.6 mA/A + 100 µA 2.8 mA/A + 400 µA 13 mA/A + 2.9 mA 0.8 mA/A + 0.7 mA 1.0 mA/A + 0.2 mA 18 mA/A + 49 mA 2.0 mA/A + 12 mA 2.1 mA/A + 12 mA 13 mA/A + 40 mA Fluke-5522A Clamp-On-Meters Up to 500 A Up to 1000 A 50 Hz 50 Hz 3.8 mA/A + 0.8 A 4.3 mA/A + 1.0 A Fluke-5522A with 50 turn coil AC Current – Measure (100 to 200) µA 200 µA to 2 mA (2 to 20) mA (20 to 200) mA (55 to 305) Hz 305 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (55 to 305) Hz 305 Hz to1 kHz (1 to 5) kHz (5 to 10) kHz (55 to 305) Hz 305 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (55 to 305) Hz 305 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 200 µA/A + 60 nA 200 µA/A + 40 nA 200 µA/A + 20 nA 200 µA/A + 80 nA 400 µA/A + 40 nA 400 µA/A + 20 nA 500 µA/A + 2 nA 400 µA/A + 9 nA 500 µA/A + 4 nA 500 µA/A + 3 nA 500 µA/A + 4 nA 500 µA/A + 15 nA 500 µA/A 500 µA/A 500 µA/A 500 µA/A 8.5-digit multimeter (Fluke-8508A)
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5265.01) 10/13/2025 Page 10 of 13 Parameter/Range Frequency CMC2, 4 (±) Comments AC Current – Measure (cont.) 200 mA to 2 A (2 to 20) A (55 to 305) Hz 305 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (55 to 305) Hz 305 Hz to 1 kHz (1 to 5 kHz (5 to 10) kHz 900 µA/A + 80 µA 900 µA/A + 80 µA 900 µA/A + 90 µA 1 mA/A + 100 µA 10 mA/A + 100 µA 10 mA/A + 100 µA 21 mA/A + 100 µA 29 mA/A + 100 µA 8.5-digit multimeter (Fluke-8508A) IV. Fluid Quantities Parameter/Equipment Range CMC2 (±) Comments Piston Operated Volumetric Apparatus 10 µl (>10 to 100) µl (>100 to 1000) µl (>1000 to 2000) µl (>2000 to 5000) µl 0.28 µl 0.31 µl 0.91 µl 1.8 µl 4.4 µl Analytical balance Laboratory Volumetric Apparatus (2 to10) ml (10 to 100) ml (100 to 200) ml 0.027 ml 0.39 ml 0.42 ml Analytical balance V. Mechanical Parameter/Equipment Range CMC2 (±) Comments Scales & Balances7 (2 to 20) mg (20 to 200) mg (200 to 500) mg 500 mg to 1 g (1 to 5) g (5 to 10) g (10 to 20) g 0.01 mg 0.02 mg 0.03 mg 0.05 mg 0.06 mg 0.07 mg 0.09 mg Standard weight set
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5265.01) 10/13/2025 Page 11 of 13 Parameter/Equipment Range CMC2, 3, 5 (±) Comments Scales & Balances7 (cont.) (20 to 50) g (50 to 100) g (100 to 200) g (200 to 500) g (500 g to 5) kg (5 to 10) kg 10 to 20) kg (20 to 100) kg 0.12 mg 0.20 mg 0.36 mg 58 mg 59 mg 61 mg 68 mg 0.58 g Standard weight set Compression & Tensile Measuring Equipment 7 Up to 50 Ton (Compression) Up to 50 Ton (Tension) 0.029 % 0.028 % Load cells with indicator Torque Tools (2.5 to 25) Nm (10 to 100) Nm (50 to 500) Nm (100 to 1000) Nm (300 to 3000) Nm 0.53 % 0.59 % 0.61 % 0.66 % 1.5 % Norbar torque tester with transducer Pressure – Measure & Measuring Equipment 7 (-1 to 0) Bar (0.03 to 2) Bar (2 to 70) Bar (20 to 1400) Bar (-0.95 to 0) Bar (0 to 200) Bar (0 to 2800) Bar 0.59 mBar 0.61 mBar 0.012 % 0.012 % 4.3 % 0.29 % 0.12 % Fluke dead weight testers Digital pressure gauge Pressure module & process calibrator Digital pressure gauge
12

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5265.01) 10/13/2025 Page 12 of 13 VI. Thermodynamics Parameter/Equipment Range CMC2, 3, 5 (±) Comments Temperature – Measuring Equipment (-40 to 150) °C (150 to 420) °C (420 to 660) °C 0.06 °C 0.07 °C 0.11 °C Temperature readout & RTD probe Temperature – Measure7 (-197 to -40) °C (-40 to 420) °C (420 to 660) °C (660 to 1000) °C 0.04 °C 0.03 °C 0.03 °C 8.7 °C Temperature readout & RTD probe Digital thermometer Temperature & Humidity – Measuring Equipment (7 to 95) % RH (10 to 50) °C 1.4 % RH 0.29 °C Humidity generator Temperature readout & RTD probe Infrared Thermometers (35 to 100) °C (100 to 350) °C (350 to 500) °C 0.95 °C 2.3 °C 3.0 °C IR calibrator VII. Time & Frequency Parameter/Equipment Range CMC 2, 5 (±) Comments Frequency – Measure 10 Hz to 350 MHz 0.08 Hz Frequency counter Timer & Stopwatch (10 to 36 000) s 0.06 s Frequency counter ____________________________ 1 This laboratory offers commercial calibration service and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration.
13

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5265.01) 10/13/2025 Page 13 of 13 3 In the statement of CMC, percentage refers to percent of reading. 4 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMC are expressed as either a specific value that covers the full range or as a fraction/percentage of the reading plus a fixed floor specification. 5 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 6 This scope meets A2LA’s P112 Flexible Scope Policy. 7 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC.
14ISO/IEC 17025:2017; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.