SAFETECH CALIBRATION LAB - A DIVISION OF SAFETY INTERNATIONAL GENERAL TRADING AND CONTRACTING CO. W.L.L.
Safety International Building, block 9 Plot 15, Shuaiba Industrial Area (West), Shuaiba, Kuwait, Shuaiba, Kuwait
Visit website- Scope lines
- 14
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 14 scope lines.
A2LA certificate 5265.01 · 14 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5265.01) 10/13/2025 Page 1 of 13
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
SAFETECH CALIBRATION LAB – A DIVISION OF SAFETY INTERNATIONAL
GENERAL TRADING AND CONTRACTING CO. W.L.L.
Safety International Building, Block 9 Plot 15
Shuaiba Industrial Area (West) KUWAIT
Suraj James Phone: 00965 97285098
CALIBRATION
Valid to: March 31, 2027 Certificate Number: 5265.01
In recognition of the successful completion of the A2LA evaluation process (including an assessment of
the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is
granted to this laboratory to perform the following calibrations
1, 6:
I. Chemical
Parameter/Equipment
Range CMC2, 3 (±) Comments
Conductivity Meters
100 µS/cm
1413 µS/cm
3.3 µS/cm
16 µS/cm
Standard conductivity
solution
pH Meters
4 pH
7 pH
10 pH
0.02 pH
0.02 pH
0.02 pH
Standard buffer
solution
II. Dimensional
Parameter/Equipment Range CMC
2 (±) Comments
Calipers
Up to 250 mm
0.01 mm Resolution
0.02 mm Resolution
5.8 µm
12 µm
Gage block set
(Grade 0)
Micrometers
Up to 25 mm
Up to 100 mm
0.61 µm
5.8 µm
Gage block set
(Grade 0) | to 250 mm |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5265.01) 10/13/2025 Page 2 of 13
Parameter/Equipment Range CMC2 (±)
Comments
Coating Thickness Gauge
Up to 1500 µm
2.8 µm
Standard foil set &
micrometer
Feeler Gauge
(0.04 to 1.00) µm
1.8 µm
Digital micrometer
Dial Indicator
Up to 25 mm
6.5 µm
Calibration tester /
indicator calibrator
Dial Thickness Gauge
Up to 25 mm
1.0 µm
Gauge blocks
III. Electrical – DC/Low Frequency
Parameter/Equipment Range CMC2, 4 (±) Comments
DC Voltage – Generate
(0 to 330) mV
(0 to 3.3) V
(0 to 33) V
(30 to 330) V
(100 to 1000) V
20 µV/V + 1 µV
10 µV/V + 7 µV
10 µV/V + 60 µV
20 µV/V + 0.4 mV
20 µV/V + 1.6 mV
Fluke-5522A
DC Voltage – Measure
(0 to 200) mV
200 mV to 2 V
(2 to 20) V
(20 to 200) V
(200 to 1000) V
6 µV/V + 0.1 µV
2 µV/V + 2 µV
3 µV/V + 10 µV
4 µV/V + 100 µV
5 µV/V + 200 µV
8.5-digit Multimeter
(Fluke-8508A)
DC High Voltage –
Measure
(2 to 40) kV
0.87 kV
HV probe Fluke 80k-40 | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5265.01) 10/13/2025 Page 3 of 13
Parameter/Equipment Range CMC2, 4 (±) Comments
DC Current – Generate
Clamp-On Meters
(0 to 330) µA
(0 to 3.3) mA
(0 to 33) mA
(0 to 330) mA
(0 to 1.1) A
(1.1 to 3) A
(0 to 11) A
(11 to 20.5) A
Up to 10 A
Up to 500 A
Up to 1000 A
100 µA/A + 20 nA
90 µA/A + 90 nA
100 µA/A + 300 nA
100 µA/A + 3 µA
200 µA/A + 90 µA
400 µA/A + 40 µA
500 µA/A + 500 µA
1.4 mA/A + 9 mA
250 µA/A + 85 mA
3.5 mA/A + 0.5 A
3.6 mA/A + 0.8 A
Fluke-5522A
Fluke-5522 with 50
turn coil
DC Current – Measure
(0 to 200) µA
200 µA to 2 mA
(2 to 20) mA
(20 to 200) mA
200 mA to 2 A
(2 to 20) A
10 µA/A + 0.7 nA
10 µA/A + 7 nA
10 µA/A + 70 nA
30 µA/A + 1 µA
200 µA/A + 20 µA
400 µA/A + 0.4 mA
8.5-digit Multimeter
Capacitance – Generate
(0.220 to 0.6) nF
(0.6 to 1) nF
(1 to 11) nF
(11 to 110) nF
110 nF to 1.1 µF
(1.1 to 11) µF
(11 to 110) µF
110 µF to 1.1 mF
(1.1 to 11) mF
(11 to 100) mF
2.1 mF/F + 10 pF
4.5 mF/F + 10 pF
2.3 mF/F + 10 pF
3.5 mF/F + 0.2 pF
3.5 mF/F
3.5 mF/F
5.8 mF/F + 30nF
5.4 mF/F + 20 nF
5.5 mF/F + 20 nF
13 mF/F + 80 µF
Fluke-5522A | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5265.01) 10/13/2025 Page 4 of 13
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Resistance – Generate
(0 to 11) Ω
(11 to 33) Ω
(33 to 110) Ω
(110 to 330) Ω
330Ω to 1.1 kΩ
(1.1 to 3.3) kΩ
(3.3 to 11) kΩ
(11 to 33) kΩ
(33 to 110) kΩ
(110 to 330) kΩ
330 kΩ to 1.1 MΩ
(1.1 to 3.3) MΩ
(3.3 to 11) MΩ
(11 to 33) MΩ
(33 to 110) MΩ
(110 to 330) MΩ
(330 to 1100) MΩ
40 µΩ/Ω + 1 mΩ
30 µΩ/Ω + 1.1 mΩ
20 µΩ/Ω + 1.3 mΩ
30 µΩ/Ω + 1.2 mΩ
40 µΩ/Ω + 4.3 mΩ
20 µΩ/Ω + 15 mΩ
20 µΩ/Ω + 23 mΩ
30 µΩ/Ω + 76 mΩ
30 µΩ/Ω + 77 mΩ
30 µΩ/Ω + 0.8 Ω
30 µΩ/Ω + 2 Ω
20 µΩ/Ω + 160 Ω
600 µΩ/Ω + 1.5 kΩ
700 µΩ/Ω + 6 kΩ
700 µΩ/Ω + 14 kΩ
18 mΩ/Ω + 2 MΩ
6.9 mΩ/Ω + 3 MΩ
Fluke-5522A
Resistance – Measure
(0 to 2) Ω
(2 to 20) Ω
(20 to 200) Ω
(200 to 2) kΩ
(2 to 20) kΩ
(20 to 200) kΩ
200 kΩ to 2 MΩ
(2 to 20) MΩ
(20 to 200) MΩ
200 MΩ to 2 GΩ
3 µΩ/Ω + 60 µΩ
6 µΩ/Ω + 60 µΩ
7 µΩ/Ω + 0.1 mΩ
0.6 µΩ/Ω + 14 mΩ
8 µΩ/Ω + 15 mΩ
8 µΩ/Ω + 0.11 Ω
10 µΩ/Ω + 1.2 Ω
20 µΩ/Ω + 100 Ω
80 µΩ/Ω + 10 kΩ
500 µΩ/Ω + 1 MΩ
8.5-digit Multimeter
(Fluke-8508A)
Insulation Resistance –
Generate
(Up to 1 kV)
Up to 1 MΩ
(1 to 10) MΩ
(10 to100) MΩ
100 MΩ to 1 GΩ
(1 to 10) GΩ
(10 to 20) GΩ
(20 to 40) GΩ
(40 to 60) GΩ
(60 to 80) GΩ
(80 to100) GΩ
0.8 kΩ
0.011 MΩ
0.79 MΩ
0.95 MΩ
0.039 GΩ
0.16 GΩ
0.62 GΩ
1.6 GΩ
2.6 GΩ
3.9 GΩ
Insulation tester
calibrator time
electronics 5069 | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5265.01) 10/13/2025 Page 5 of 13
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Insulation Resistance –
Generate (cont)
(Up to 10 kV)
100 MΩ to 1 GΩ
(1 to 10) GΩ
(10 to 20) GΩ
(20 to 40) GΩ
(40 to 60) GΩ
(60 to 80) GΩ
(80 to100) GΩ
0.95 MΩ
0.039 GΩ
0.16 GΩ
0.62 GΩ
1.6 GΩ
2.6 GΩ
3.9 GΩ
Insulation tester
calibrator time
electronics 5069
Electrical Simulation of
Temperature Instruments
– Generate
Pt 100
Type B
Type C
Type E
Type J
Type K
Type L
Type N
Type R
Type S
Type T
Type U
(-200 to 0) °C
(0 to 800) °C
(600 to 1800) °C
(0 to 2300) °C
(-250 to 1000) °C
(-200 to 1200) °C
(-200 to 1350) °C
(-200 to 900) °C
(-200 to 1300) °C
(0 to 1700) °C
(0 to 1700) °C
(-250 to 400) °C
(-200 to 600) °C
0.0001 °C/°C + 0.07 °C
0.0002 °C/°C + 0.07 °C
0.45 °C
0.85 °C
0.51 °C
0.29 °C
0.42 °C
0.39 °C
0.42 °C
0.58 °C
0.48 °C
0.64 °C
0.57 °C
Fluke-5522A
Electrical Simulation of
Temperature Instruments
– Measure
Pt 100
Type B
Type C
Type E
Type J
Type K
Type L
Type N
Type R
Type S
Type T
Type U
(-200 to 0) °C
(0 to 800) °C
(600 to 1800) °C
(0 to 2300) °C
(-250 to 1000) °C
(-200 to 1200) °C
(-200 to 1350) °C
(-200 to 900) °C
(-200 to 1300) °C
(0 to 1700) °C
(0 to 1700) °C
(0 to 400) °C
(-200 to 600) °C
0.1 °C
0.24 °C
0.47 °C
0.86 °C
0.53 °C
0.32 °C
0.43 °C
0.41 °C
0.43 °C
0.59 °C
0.50 °C
0.65 °C
0.59 °C
Fluke-5522A & 8.5-
digital multimeter
(Fluke-8508A)
Fluke-5522A | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5265.01) 10/13/2025 Page 6 of 13
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
AC Voltage – Generate
(3 to 33) mV
(33 to 330) mV
(0.33 to 3.3) V
(3.3 to 33) V
(33 to 330) V
(330 to 1020) V
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 450) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 450) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 90) kHz
45 Hz to 1 kHz
(1 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 8) kHz
0.5 mV/V + 6 µV
0.6 mV/V + 6 µV
0.9 mV/V + 6 µV
1.8 mV/V + 9 µV
5.6 mV/V + 20 µV
0.2 mV/V + 30 µV
0.2 mV/V + 20 µV
0.1 mV/V + 20 µV
0.2 mV/V + 30 µV
0.1 mV/V + 70 µV
0.1 mV/V + 90 µV
0.2 mV/V + 100 µV
0.2 mV/V + 200 µV
0.2 mV/V + 200 µV
0.3 mV/V + 300 µV
0.5 mV/V + 700 µV
1.4 mV/V + 0.3 mV
0.1 mV/V + 400 µV
0.1 mV/V + 200 µV
0.2 mV/V + 30 µV
0.3 mV/V + 0.2 mV
0.5 mV/V + 0.4 mV
0.1 mV/V + 0.4 mV
0.2 mV/V + 0.8 mV
0.2 mV/V + 0.6 mV
0.2 mV/V + 0.9 mV
0.7 mV/V + 7.0 mV
0.3 mV/V + 66 mV
0.3 mV/V + 62 mV
0.4 mV/V + 68 mV
Fluke-5522A | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5265.01) 10/13/2025 Page 7 of 13
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Voltage – Measure
(100 to 200) mV
200 mV to 2 V
(2 to 20) V
(20 to 200) V
(20 to 55) Hz
(55 to 305) Hz
305 Hz to 1kHz
(1 to 3) kHz
(3 to 10) kHz
(10 to 30) kHz
(30 to 60) kHz
(60 to 100) kHz
(20 to 55) Hz
(55 to 305) Hz
305 Hz to 1kHz
(1 to 3) kHz
(3 to 10) kHz
(10 to 30) kHz
(30 to 60) kHz
(60 to 100) kHz
(100 to 500) kHz
500 kHz to 1 MHz
(20 to 55) Hz
(55 to 305) Hz
305 Hz to 1kHz
(1 to 3) kHz
(3 to 10) kHz
(10 to 30) kHz
(30 to 60) kHz
(60 to 100) kHz
(100 to 500) kHz
500 kHz to 1 MHz
0.1 mV/V + 6 µV
0.1 mV/V + 5 µV
0.1 mV/V + 3 µV
0.1 mV/V + 3 µV
0.1 mV/V + 4 µV
0.2 mV/V + 7 µV
0.5 mV/V + 10 µV
0.7 mV/V + 20 µV
100 µV/V + 6 µV
80 µV/V + 7 µV
70 µV/V + 8 µV
90 µV/V + 6 µV
100 µV/V + 5 µV
200 µV/V + 10 µV
400 µV/V + 20 µV
700 µV/V + 30 µV
19 mV/V + 3.6 mV
30 mV/V
80 µV/V + 60 µV
50 µV/V + 10 µV
40 µV/V + 10 µV
90 µV/V + 70 µV
100 µV/V + 10 µV
200 µV/V + 60 µV
500 µV/V
700 µV/V
15 mV/V
30 mV/V
Fluke-8508A | ||
| 8 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5265.01) 10/13/2025 Page 8 of 13
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Voltage – Measure (cont.)
(200 to 1000) V
(55 to 305) Hz
305 Hz to 1kHz
(1 to 3) kHz
(3 to 10) kHz
(10 to 30) kHz
100 µV/V + 17 mV
100 µV/V + 13 mV
100 µV/V + 15 mV
100 µV/V + 15 mV
200 µV/V + 40 mV
Fluke-8508A
AC High Voltage – Measure
(2 to 28) kV
50 Hz
1.6 kV
HV Probe (Fluke
80k-40)
AC Current – Generate
(29 to 330) µA
(0.33 to 3.3) mA
(3.3 to 33) mA
(33 to 330) mA
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
1.7 mA/A + 100 nA
1.4 mA/A + 100 nA
2.1 mA/A + 100 nA
5.5 mA/A + 200 nA
12 mA/A + 300 nA
16 mA/A + 400 nA
1.6 mA/A + 200 nA
1.0 mA/A + 200 nA
0.8 mA/A + 200 nA
1.2 mA/A + 400 nA
2.6 mA/A + 800 nA
5.6 mA/A + 2 µA
1.5 mA/A + 300 nA
0.4 mA/A + 2 µA
0.4 mA/A + 1 µA
0.5 mA/A + 2 µA
1.1 mA/A + 6 µA
2.1 mA/A + 10 µA
1.6 mA/A
0.8 mA/A + 7 µA
0.4 mA/A + 5 µA
2.1 mA/A + 100 µA
1.4 mA/A + 2 µA
2.9 mA/A + 10 µA
Fluke-5522A | 200 to 1000 V |
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5265.01) 10/13/2025 Page 9 of 13
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Current – Generate (cont.)
(0.33 to 1.1) A
(1.1 to 3) A
(3 to 11) A
(11 to 20.5) A
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
1.1 mA/A + 20 µA
0.5 mA/A + 10 µA
4.2 mA/A + 1.2 mA
8.0 mA/A + 2.3 mA
1.1 mA/A + 70 µA
0.6 mA/A + 100 µA
2.8 mA/A + 400 µA
13 mA/A + 2.9 mA
0.8 mA/A + 0.7 mA
1.0 mA/A + 0.2 mA
18 mA/A + 49 mA
2.0 mA/A + 12 mA
2.1 mA/A + 12 mA
13 mA/A + 40 mA
Fluke-5522A
Clamp-On-Meters
Up to 500 A
Up to 1000 A
50 Hz
50 Hz
3.8 mA/A + 0.8 A
4.3 mA/A + 1.0 A
Fluke-5522A with
50 turn coil
AC Current – Measure
(100 to 200) µA
200 µA to 2 mA
(2 to 20) mA
(20 to 200) mA
(55 to 305) Hz
305 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(55 to 305) Hz
305 Hz to1 kHz
(1 to 5) kHz
(5 to 10) kHz
(55 to 305) Hz
305 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(55 to 305) Hz
305 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
200 µA/A + 60 nA
200 µA/A + 40 nA
200 µA/A + 20 nA
200 µA/A + 80 nA
400 µA/A + 40 nA
400 µA/A + 20 nA
500 µA/A + 2 nA
400 µA/A + 9 nA
500 µA/A + 4 nA
500 µA/A + 3 nA
500 µA/A + 4 nA
500 µA/A + 15 nA
500 µA/A
500 µA/A
500 µA/A
500 µA/A
8.5-digit multimeter
(Fluke-8508A) | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5265.01) 10/13/2025 Page 10 of 13
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Current – Measure
(cont.)
200 mA to 2 A
(2 to 20) A
(55 to 305) Hz
305 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(55 to 305) Hz
305 Hz to 1 kHz
(1 to 5 kHz
(5 to 10) kHz
900 µA/A + 80 µA
900 µA/A + 80 µA
900 µA/A + 90 µA
1 mA/A + 100 µA
10 mA/A + 100 µA
10 mA/A + 100 µA
21 mA/A + 100 µA
29 mA/A + 100 µA
8.5-digit multimeter
(Fluke-8508A)
IV. Fluid Quantities
Parameter/Equipment
Range CMC2 (±) Comments
Piston Operated
Volumetric Apparatus
10 µl
(>10 to 100) µl
(>100 to 1000) µl
(>1000 to 2000) µl
(>2000 to 5000) µl
0.28 µl
0.31 µl
0.91 µl
1.8 µl
4.4 µl
Analytical balance
Laboratory Volumetric
Apparatus
(2 to10) ml
(10 to 100) ml
(100 to 200) ml
0.027 ml
0.39 ml
0.42 ml
Analytical balance
V. Mechanical
Parameter/Equipment
Range CMC2 (±) Comments
Scales & Balances7
(2 to 20) mg
(20 to 200) mg
(200 to 500) mg
500 mg to 1 g
(1 to 5) g
(5 to 10) g
(10 to 20) g
0.01 mg
0.02 mg
0.03 mg
0.05 mg
0.06 mg
0.07 mg
0.09 mg
Standard weight set | ||
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5265.01) 10/13/2025 Page 11 of 13
Parameter/Equipment
Range CMC2, 3, 5 (±) Comments
Scales & Balances7
(cont.)
(20 to 50) g
(50 to 100) g
(100 to 200) g
(200 to 500) g
(500 g to 5) kg
(5 to 10) kg
10 to 20) kg
(20 to 100) kg
0.12 mg
0.20 mg
0.36 mg
58 mg
59 mg
61 mg
68 mg
0.58 g
Standard weight set
Compression & Tensile
Measuring Equipment 7
Up to 50 Ton
(Compression)
Up to 50 Ton (Tension)
0.029 %
0.028 %
Load cells with
indicator
Torque Tools
(2.5 to 25) Nm
(10 to 100) Nm
(50 to 500) Nm
(100 to 1000) Nm
(300 to 3000) Nm
0.53 %
0.59 %
0.61 %
0.66 %
1.5 %
Norbar torque tester
with transducer
Pressure – Measure &
Measuring Equipment 7
(-1 to 0) Bar
(0.03 to 2) Bar
(2 to 70) Bar
(20 to 1400) Bar
(-0.95 to 0) Bar
(0 to 200) Bar
(0 to 2800) Bar
0.59 mBar
0.61 mBar
0.012 %
0.012 %
4.3 %
0.29 %
0.12 %
Fluke dead weight
testers
Digital pressure gauge
Pressure module &
process calibrator
Digital pressure gauge | ||
| 12 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5265.01) 10/13/2025 Page 12 of 13
VI. Thermodynamics
Parameter/Equipment
Range CMC2, 3, 5 (±) Comments
Temperature – Measuring
Equipment
(-40 to 150) °C
(150 to 420) °C
(420 to 660) °C
0.06 °C
0.07 °C
0.11 °C
Temperature readout & RTD
probe
Temperature – Measure7
(-197 to -40) °C
(-40 to 420) °C
(420 to 660) °C
(660 to 1000) °C
0.04 °C
0.03 °C
0.03 °C
8.7 °C
Temperature readout & RTD
probe
Digital thermometer
Temperature & Humidity
– Measuring Equipment
(7 to 95) % RH
(10 to 50) °C
1.4 % RH
0.29 °C
Humidity generator
Temperature readout & RTD
probe
Infrared Thermometers
(35 to 100) °C
(100 to 350) °C
(350 to 500) °C
0.95 °C
2.3 °C
3.0 °C
IR calibrator
VII. Time & Frequency
Parameter/Equipment Range CMC
2, 5 (±) Comments
Frequency – Measure
10 Hz to 350 MHz
0.08 Hz
Frequency counter
Timer & Stopwatch
(10 to 36 000) s
0.06 s
Frequency counter
____________________________
1 This laboratory offers commercial calibration service and field calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration. | ||
| 13 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 5265.01) 10/13/2025 Page 13 of 13
3 In the statement of CMC, percentage refers to percent of reading.
4 The stated measured values are determined using the indicated instrument (see Comments). This capability
is suitable for the calibration of the devices intended to measure or generate the measured value in the
ranges indicated. CMC are expressed as either a specific value that covers the full range or as a
fraction/percentage of the reading plus a fixed floor specification.
5 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
6 This scope meets A2LA’s P112 Flexible Scope Policy.
7 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC. | ||
| 14 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.