Hunter Associates Laboratory,

11491 Sunset HIlls Road, 20190, Reston, VA, United States

Visit website
A2LA 6005.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
3
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 3 scope lines.

A2LA certificate 6005.01 · 3 lines

LineMethodMatrixRange
1--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6005.01) 02/20/2025 Page 1 of 2 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 HUNTER ASSOCIATES LABORATORY, INC. 11491 Sunset Hills Rd Reston, VA 20190 Bill Babiarz Phone: 703 471 6870 CALIBRATION Valid To: April 30, 2027 Certificate Number: 6005.01 In recognition of the successful co mpletion of the A2LA evaluation process (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 5: I. Optical Quantities Parameter/Equipment Range6 CMC2, 4, 7 (±) Comments di:8 RSIN Spectral Reflectance Factor3 – Measuring Equipment, Xenon Illumination (80 to 100) % R (350 to 375) nm (380 to 400) nm (405 to 460) nm (465 to 795) nm (800 to 1000) nm 2.8 % 1.5 % 0.65 % 0.46 % 1.6 % Reflectance standard white tile de:8 RSEX Spectral Reflectance Factor 3 – Measuring Equipment, Xenon Illumination (80 to 100) % R (350 to 375) nm (380 to 400) nm (405 to 460) nm (765 to 795) nm (800 to 1000) nm 2.8 % 1.5 % 0.65 % 0.46 % 1.6 % Reflectance standard white tile 0:45 Spectral Reflectance Factor 3 – Measuring Equipment, LED Illumination (80 to 100) % R (400) nm (410 to 460) nm (470 to 700) nm 1.4 % 0.75 % 0.75 % Reflectance standard white tile 45:0 Spectral Reflectance Factor3 – Measuring Equipment, Xenon Illumination (80 to 100) % R (400 to 420) nm (430 to 680) nm (690 to 700) nm 1.4 % 0.75 % 0.75 % Reflectance standard white tile
80 to 100 % R
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 6005.01) 02/20/2025 Page 2 of 2 Parameter/Equipment Range6 CMC2, 4, 7 (±) Comments 8:T Spectral Transmittance Factor3 – Measuring Equipment, Xenon Illumination (60 to 100) % T (350 to 385) nm (390 to 800) nm (805 to 840) nm (845 to 1000) nm 0.31 % 0.32 % 0.28 % 1.2 % Neutral density filter NG11 0:T Spectral Transmittance Factor 3 – Measuring Equipment, LED Illumination 100 % T (400 to 420) nm (430 to 680) nm (690 to 700) nm 0.85 % 0.58 % 0.78 % Diffuse illumination sphere _________________________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (C MC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be e xpected to be larger than the Calibration and Measurement Capability Uncertainty (CMC) found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equi pment. The usual allowance for the uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty ach ievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, percentages are percentage of reading, unless otherwise indicated. 5 This scope meets A2LA’s P112 Flexible Scope Policy. 6 In the statement of range, R is defined as reflectance and T is defined as transmittance. 7 The type of instrument or material being calibrate d is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter.
3

Extracted from the scope document; tables may not line up. View scope for the original.

For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation. Accredited Laboratory A2LA has accredited HUNTER ASSOCIATES LABORATORY, INC Reston, VA for technical competence in the field of Calibration This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This laboratory also meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 20th day of February 2025. __ _____________________ Mr. Trace McIntruff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 6005.01 Valid to April 30, 2027

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

11491 Sunset HIlls Road, Reston, VA, 20190, US

38.95328, -77.34645

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.