United States

API Services

750 City Center Blvd., 23606, Newport News, VA, United States

Visit website
A2LA 2229.02ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
4
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 4 scope lines.

A2LA certificate 2229.02 · 4 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017-See scope document
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2229.02) 09/10/2025 Page 2 of 3 Parameter/Equipment Range CMC2 (±) Comments Squareness3 90° ± 600 arc secs 0.22 arc secs Pentaprism Volumetric Machine Mapping3 – Centering ADM Offset Up to 1 mm Up to 100 mm 0.23 µm 2.1 µm Active target Volumetric Machine Mapping3 Up to 80 m 0.87 µm/m IFM based laser tracking system (Radian T3/T3+, T2/T2+) Volumetric Machine Mapping 3 Up to 100 m 0.97 µm/m ADM based laser tracking system (OT2/OT) Rotational Positioning3 (-360 to 360)° (2.2 + [0.006A + 0.1]) arc secs Swivel check A = area Circular Interpolation Volume3 Up to 6 mm 0.06 µm Telescoping ball bar Laser Interferometer Measuring System with Weather Station (1D, 3D, 5D, and 6D) – Displacement Angle Straightness Wavelength Up to 80 m Up to 1000 arc seconds Up to 3 mm 633 nm 0.1 μm/m 0.07 arc seconds 0.04 μm 0.02 ppm 1st ref. laser, frequency counter, 1st ref. thermometer 1st ref. pressure sensor, trans. ref. laser, weather station frequency counter / XD laser Scale Bar 800 mm 0.15 μm/m Trans. ref laser, weather station Straightness Sensor Up to 3 mm 0.04 μm/m Trans. ref. laser
3-Air
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2229.02) 09/10/2025 Page 3 of 3 Parameter/Equipment Range CMC2 (±) Comments Angle Sensor Up to 800 arc seconds 0.07 arc seconds Trans. ref. laser XD Level Reference Up to 1° 0.07 arc seconds Trans. ref. laser vProbe (50mm / 100mm) Pitch: 80° Yaw: 80° Roll: 60° 0.94 µm/m 0.94 µm/m 1.1 µm/m Laser tracking system, angle encoder II. Thermodynamics Parameter/Equipment Range CMC2 (±) Comments Weather Station – Temperature Air Pressure (-10 to 60) °C (375 to 825) mmHg 0.07 °C 0.1 mmHg 1 st ref. thermometer 1 st ref. pressure sensor ________________________________________ 1 This laboratory offers commercial calibration service and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 Instrument is calibrated by a laboratory accredited to ISO/IEC 17025 by an accreditation body that is a signatory of the ILAC Mutual Recognition Arrangement or by a National Metrology Institute. (e.g. NIST and NIM). 5 This scope meets A2LA’s P112 Flexible Scope Policy.
to 800 arc seconds
4ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.