Laboratorio SVEPPI di Siemens Energy
Via Cornarotta 65 (ingresso da Via Alessandro Volta 34/A), 30030, Salzano, Italy
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at Laboratorio SVEPPI di Siemens Energy?
Claim this profile to keep it accurate.
Register record
- ACCREDIARefreshed
- 00721Active
Certificates and scope
1ISO/IEC 17025
Active00721
Accredited scope, certificate 00721
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | electrical | CEI EN 61442:2006; EN 61442:2005; IEC 61442:2023; CEI EN 62271-1:2019/A1:2022; EN 62271-1:2017/A1:2021; IEC 62271-1:2017/Amd1:2021; CEI EN 62271-100:2013/A1:2014/A2:2018/EC:2018 | Accessories for power cables with rated voltages from 6 kV (Um = 7,2 kV) up to 36 kV (Um = 42 kV); Apparecchiatura di manovra e di comando ad alta tensione in corrente alternata; Apparecchiatura di manovra e di comando ad alta tensione: interruttori a corrente alternata | 6 to 42 kV |
| 2 | electrical | IEC 62271-100:2021/COR1:2021/COR2:2022/COR3:2024; CEI EN IEC 62271-103:2024; IEC 62271-103:2021 | Apparecchiatura di manovra e di comando ad alta tensione: interruttori di manovra e interruttori di manovra sezionatori per tensioni nominali superiori a 1 kV fino a 52 kV compreso/High-voltage switchgear and controlgear: switches and switch-disconnectors for rated voltages above 1 kV up to and including 52 kVV; Apparecchiatura di manovra e di comando ad alta tensione: per tensioni nominali comprese tra 1 kV e 52 kV inclusi/High-voltage switchgear and controlgear: for rated voltages above 1 kV and up to and including 52 kV | 1 to 52 kV |
| 3 | electrical | CEI EN IEC 62271-102:2019; IEC 62271-102:2018/AMD1:2022; CEI EN 61439-6:2013; IEC 61439-6:2012; CEI EN IEC 61439-2:2021; IEC 61439-2:2020; CEI EN IEC 61439-1:2022; IEC 61439-1:2020/COR1:2021; ENEL DY 1100 (2002) | Apparecchiature assiemate di protezione e di manovra per bassa tensione (quadri BT): Condotti sbarre/Low-voltage switchgear and controlgear assemblies: Busbar trunking systems (busways); Apparecchiature assiemate di protezione e di manovra per bassa tensione (quadri BT): Quadri di potenza/Low-voltage switchgear and controlgear assemblies: Power switchgear and controlgear assemblies; Apparecchiature assiemate di protezione e di manovra per bassa tensione (quadri BT)/Low-voltage switchgear and controlgear assemblies; Apparecchiature prefabbricate a 24 kV con involucro metallico per cabine secondarie/24 kV prefabricated equipment with metal casing for secondary substations; Cavi isolati e loro accessori per sistemi di potenza – Giunti rettilinei prefabbricati unipolari, giunti di derivazione e terminali di chiusura per cavi con isolamento sintetico con tensioni nominali da 6/10(12) kV a 18/30(36) kV/lnsulated cables and their accessories for pow | 0 to 10000 cicli |
| 4 | electrical | CEI EN 62231:2007; IEC 62231:2006; CEI EN 60660:2000; IEC 60660:1999; IEC 60099-4:2014; ENEL DY 1000 (2002); Specifica Tecnica TERNA INS AA S 01 (2016); CEI EN 61869-2:2014; IEC 61869-2:2012 | Isolatori portanti compositi per stazioni per tensioni alternate superiori a 1000 V e fino a 245 kV/Composite station post insulators for substations with a.c. voltages greater than 1 000 V up to 245 kV; Isolatori portanti per interno di materiale organico destinati ad impianti con tensione superiore a 1000 V e inferiore a 300 kV/Indoor post insulators of organic material for systems with nominal voltages greater than 1 kV up to but not including 300 kV; Scaricatori ad ossido metallico senza spinterometri per reti elettriche a corrente alternata/Metal-oxide surge arresters without gaps for a.c. systems; Sezionatori di media tensione per interno isolati in aria e in contenitori isolati in SF6 per quadri per cabine secondarie e apparecchi da palo/ Indoor medium voltage disconnectors insulated in air and in SF6 insulated containers for switchboards for secondary substations and pole-mounted luminaires; Trasformatori di corrente ad alta tensione ad affidabilità incrementata/High voltage current transformers with increased reliability; Trasformatori di corrente/Current transformers; Trasformatori di potenza di tipo a secco/Dry-type power transformers | to 245 kV |
| 5 | electrical | CEI EN 60076-1:2015; IEC 60076-1:2011; CEI EN 60076-5:2007; EN 60076-5:2006; IEC 60076-5:2000; CEI EN 60076-2:2015; IEC 60076-2:2011 | Trasformatori sino a 5 kVA; trasformatori immersi in liquidi | to 5 kVA |
| 6 | electrical | UNI CEI EN ISO/IEC 17025:2018; CEI EN 62271-200:2013/EC:2015; CEI EN IEC 62271-200:2022; IEC 62271-200:2021; CEI EN 61439-6:2013; IEC 61439-6:2012; CEI EN IEC 61439-1:2022; IEC 61439-1:2020/COR1:2021; CEI EN IEC 60076-11:2019; IEC 60076-11:2018 RLV; CEI EN 60076-5:2007; EN 60076-5:2006; IEC 60076-5:2000; CEI EN 60076-2:2015; IEC 60076-2:2011 | Apparecchiatura di manovra e di comando ad alta tensione; Apparecchiature assiemate di protezione e di manovra per bassa tensione (quadri BT); Trasformatori di potenza di tipo a secco; Trasformatori di potenza; Sovratemperature in trasformatori immersi in liquidi | 1 to 52 kV |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Via Cornarotta 65 (ingresso da Via Alessandro Volta 34/A), Salzano, 30030, IT
45.52134, 12.10637
Open in MapsAccreditation data refreshed from the ACCREDIA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ACCREDIA entry linked above.