Shenzhen BANTEK Testing Co.,
A5&A6, Building B1&B2, No.45 Gangtou Road, Bogang Community, Shajing Street, Bao'an District, Shenzhen, 518104, People's Republic of China, Shenzhen, China
Visit website- Accredited standards
- 16
- A2LA certificate
- 1
- Sites in our directory
- 2
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 16 standard numbers and the 13 official names we hold. When no standard matches, it searches the method text of every scope line.
IEC 61000 series7
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
CISPR4
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement+1 national
National versions in the same scope
AS CISPR 11national version with changes
CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission+2 national
National versions in the same scope
AS CISPR 14.1national version with changes
AS/NZS CISPR 14.1national version with changes
CISPR 15Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment+2 national
National versions in the same scope
AS CISPR 15national version with changes
AS/NZS CISPR 15national version with changes
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+1 national
National versions in the same scope
AS/NZS CISPR 32identical to it
Other standards5
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
ANSI C63.10
EN 50563
EN 50564
FCC PART 15Radio Frequency Devices
ISO/IEC 17025:2017; CFR 47; FCC Part 15; Subpart B (using ANSI C63.4:2014); CFR 47; FCC Part 18 (using FCC MP-5:1986); CAN/CSA-CEI/IEC CISPR 11; CSA-CISPR 11; AS CISPR 11; BS EN 55011; EN 55011; CISPR 11; ICES-001; ICES-003; ICES-005; BS EN IEC 55014-1; EN IEC 55014-1; CISPR 14-1; AS/NZS CISPR 14.1; AS CISPR 14.1; BS EN 55015; BS EN IEC 55015; EN 55015; EN IEC 55015; CISPR 15; AS/NZS CISPR 15; AS CISPR 15; BS EN 55032; EN 55032; CISPR 32; AS/NZS CISPR 32; BS EN 61000-3-2; BS EN IEC 61000-3-2; EN 61000-3-2; EN IEC 61000-3-2; IEC 61000-3-2; BS EN IEC 61000-3-3; IEC 61000-3-3; EN 61000-3-3; BS EN 61000-4-2; IEC 61000-4-2; EN 61000-4-2; BS EN 61000-4-3; BS EN IEC 61000-4-3; IEC 61000-4-3; EN 61000-4-3; EN IEC 61000-4-3; BS EN 61000-4-4; IEC 61000-4-4; EN 61000-4-4; BS EN 61000-4-5; IEC 61000-4-5; EN 61000-4-5; BS EN 61000-4-6; IEC 61000-4-6; EN 61000-4-6
EN 50563; BS EN 50563; EN 50564; BS EN 50564; AS/NZS 4665.1; AS/NZS 4665.2; 10 C.F.R. section 430.23(bb); 10 C.F.R. Section 430.23(aa); 10 C.F.R. section 430.23(h); ANSI C63.4:2014; FCC MP-5 (February 1986); ANSI C63.10:2013; ANSI C63.10:2020; FCC KDB 905462 D02 (v02)
ANSI C63.10:2013; ANSI C63.10:2020; ANSI/TIA-603-E; TIA-102.CAAA-E; ANSI C63.26:2015; ANSI/TIA-603-E; ANSI/TIA-603-E
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
6 lines
ISO/IEC 17025
Active6798.01
The scope document we hold says it is valid until 2027-04-30.
Accredited scope, certificate 6798.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; CFR 47; FCC Part 15; Subpart B (using ANSI C63.4:2014); CFR 47; FCC Part 18 (using FCC MP-5:1986); CAN/CSA-CEI/IEC CISPR 11; CSA-CISPR 11; AS CISPR 11; BS EN 55011; EN 55011; CISPR 11; ICES-001; ICES-003; ICES-005; BS EN IEC 55014-1; EN IEC 55014-1; CISPR 14-1; AS/NZS CISPR 14.1; AS CISPR 14.1; BS EN 55015; BS EN IEC 55015; EN 55015; EN IEC 55015; CISPR 15; AS/NZS CISPR 15; AS CISPR 15; BS EN 55032; EN 55032; CISPR 32; AS/NZS CISPR 32; BS EN 61000-3-2; BS EN IEC 61000-3-2; EN 61000-3-2; EN IEC 61000-3-2; IEC 61000-3-2; BS EN IEC 61000-3-3; IEC 61000-3-3; EN 61000-3-3; BS EN 61000-4-2; IEC 61000-4-2; EN 61000-4-2; BS EN 61000-4-3; BS EN IEC 61000-4-3; IEC 61000-4-3; EN 61000-4-3; EN IEC 61000-4-3; BS EN 61000-4-4; IEC 61000-4-4; EN 61000-4-4; BS EN 61000-4-5; IEC 61000-4-5; EN 61000-4-5; BS EN 61000-4-6; IEC 61000-4-6; EN 61000-4-6 | - | to 40 GHz |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6798.01) Revised 05/29/2025 Page 2 of 5
Test Technology: Test Method(s):
Power frequency magnetic field
immunity (PFMF)
BS EN 61000-4-8; EN 61000-4-8; IEC 61000-4-8
Voltage Dips,
Short Interruptions,
and Voltage Variations (VDI)
(*see Table #1 limitation list below)
BS EN 61000-4-11; BS EN IEC 61000-4-11; IEC 61000-4-11;
EN 61000-4-11; EN IEC 61000-4-11
Generic and Product Specific EMC BS EN 55014-2; EN 55014-2; CISPR 14-2;
AS/NZS CISPR 14.2; EN 62040-2;
BS EN 61547; IEC 61547; EN 61547;
BS EN 55035; EN 55035; CISPR 35;
BS EN 61000-6-1; BS EN IEC 61000-6-1; IEC 61000-6-1;
EN 61000-6-1; EN IEC 61000-6-1;
BS EN 61000-6-2; BS EN IEC 61000-6-2; IEC 61000-6-2;
EN 61000-6-2; EN IEC 61000-6-2;
BS EN 61000-6-3; IEC 61000-6-3; EN 61000-6-3;
AS/NZS 61000.6.3;
BS EN 61000-6-4; BS EN IEC 61000-6-4; IEC 61000-6-4;
EN 61000-6-4; EN IEC 61000-6-4; AS/NZS 61000.6.4;
EN 301 489-1; EN 301 489-3; EN 301 489-9;
EN 301 489-17; EN 301 489-19; EN 301 489-52;
AS/NZS 60669.2.1; IEC 60669-2-1; EN 60669-2-1;
BS EN 60669-2-1; SANS 60669-2-1; AS/NZS 61058.1;
IEC61058-1; EN 61058-1; BS EN 61058-1; SANS 61058-1;
IEC 60730-1; EN 60730-1; BS EN 60730-1; SANS 60730-1;
UL 60730-1
Radio Communications
Intentional and Unintentional
Radiators
47 CFR Part 15C (using ANSI C63.10:2013, ANSI
C63.10:2020);
47 CFR Part 15E (using ANSI C63.10:2013, ANSI
C63.10:2020);
47 CFR Part 15F (using ANSI C63.10:2013, ANSI
C63.10:2020); and FCC KDB 905462 D02 (v02));
AS/NZS 4268;
RSS-130; RSS-132; RSS-133; RSS-139; RSS-195;
RSS-199; RSS-210 (Up to 40 GHz); RSS-216 (Up to 40 GHz);
RSS-247; RSS-248; RSS-GEN;
47 CFR Parts 22, 24, 25, 90, 95, 96, 97, 27, and 101
(using ANSI/TIA-603-E; TIA-102.CAAA-E; or ANSI
C63.26:2015);
ANSI C63.4; ANSI C63.10; ANSI C63.26;
ANSI/TIA 603-E; TIA-102.CAAA-E;
EN 300 328; EN 301 893; EN 300 220-1; EN 300 220-2;
EN 300 220-3-1; EN 300 220-3-2; EN 300220-4;
EN 300 440; EN 302 502; EN 300 330; EN 300 422-1;
EN 300 422-2; EN 300 422-3; EN 300 422-4; EN 303 413;
EN 301 357; EN 303 345-1; EN 303 345-2; EN 303 345-3;
EN 303 345-4; EN 303 345-5; EN 301 511; ETSI EN 301 908-1;
EN 301 908-2; EN 301 908-13; EN 303 417 | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6798.01) Revised 05/29/2025 Page 3 of 5
Test Technology: Test Method(s):
RF Exposure BS EN 62311; IEC 62311; EN 62311; EN IEC 62311;
BS EN 62479; IEC 62479; EN 62479; AS/NZS 2772.2
Household Appliances
IEC 60335-1; EN 60335-1; AS/NZS 60335.1;
IEC 60335-2-14; EN 60335-2-14; AS/NZS 60335.2.14;
IEC60335-2-23; EN60335-2-23; EN IEC 60335-2-23;
AS/NZS 60335.2.23;
IEC 60335-2-15; EN 60335-2-15; AS/NZS 60335.2.15;
IEC 60335-2-29; EN IEC 60335-2-29; AS/NZS 60335.2.29;
IEC 60335-2-41; EN 60335-2-41; AS/NZS 60335.2.41;
IEC 60335-2-43; EN 60335-2-43; AS/NZS 60335.2.43; UL 499;
UL 141; UL 507; UL 859; UL982; UL 998; UL1278; UL1746;
UL130
Audio/video; information and
communication technology
equipment
IEC 62368-1; EN 62368-1; BS EN 62368-1; AS/NZS 62368.1;
UL 62368-1; CAN/CSA-C22.2 No.62368-1; EN 62040-1;
IEC62040-1; BS EN IEC62040-1; AS 62040.1; UL1778;
EN 62040-3; IEC 62680-1-1; EN 62680-1-1; IEC 62680-1-2;
EN 62680-1-2; IEC 62680-1-3; EN 62680-1-3;
EN IEC 62680-1-1; IEC 62680-1-1; EN62680-1-2;
IEC 62680-1-2; EN62680-1-3; IEC 62680-1-3
Inverter UL458; UL1741; EN/IEC 62109-1; EN/IEC 62109-2;
EN/IEC 61683; EN/IEC 62477-1; IEEE1547
Luminaires IEC 60598-1; EN 60598-1; AS/NZS 60598.1;
IEC 60598-2-1; EN 60598-2-1; AS/NZS 60598.2.1;
IEC 60598-2-2; EN 60598-2-2; AS/NZS 60598.2.2;
IEC 60598-2-3; EN 60598-2-3; AS/NZS 60598.2.3;
IEC 60598-2-4; EN 60598-2-4; AS/NZS 60598.2.4;
IEC 60598-2-5; EN 60598-2-5; AS/NZS 60598.2.5;
IEC 62560; EN 62560; BS EN 62560; AS/NZS 62560;
UL 588; UL153; UL 1576
Power Supply IEC 61347-1; EN 61347-1; BS EN 61347-1; AS/NZS 61347.1;
IEC 61347-2-13; EN 61347-2-13; BS EN 61347-2-13;
AS/NZS 61347.2.13; UL 2738; UL 2089
Electrical accessories
UL1363; UL 498A; UL498; UL60730-1; UL817; NEK 502;
SFS 5610; SS 428 08 34; DS 60884-2-D1; IS 1293;
UNE 20315-1; UNE 20316-2; OVE/ONORM E 8684-1;
NEN 1020; AS/NZS 3190; IEC 61984; EN 61984; IEC 60669-1;
EN 60669-1; AS/NZS 60669.1;
IEC 60669-2-1; EN 60669-2-1; AS/NZS 60669.2.1;
IEC 61058-1; EN 61058-1; AS/NS 61058.1; IEC 61058-1-2;
EN 61058-1-2; AS/NS 61058.1.2; IEC 60730-1; EN 60730-1;
AS/NZS 3190; EN 61984; IEC 61984 | ||
| 4 | EN 50563; BS EN 50563; EN 50564; BS EN 50564; AS/NZS 4665.1; AS/NZS 4665.2; 10 C.F.R. section 430.23(bb); 10 C.F.R. Section 430.23(aa); 10 C.F.R. section 430.23(h); ANSI C63.4:2014; FCC MP-5 (February 1986); ANSI C63.10:2013; ANSI C63.10:2020; FCC KDB 905462 D02 (v02) | - | to 40000 MHz |
| 5 | ANSI C63.10:2013; ANSI C63.10:2020; ANSI/TIA-603-E; TIA-102.CAAA-E; ANSI C63.26:2015; ANSI/TIA-603-E; ANSI/TIA-603-E | - | to 40000 MHz |
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
SHENZHEN BANTEK TESTING CO., LTD.
Shenzhen, People’s Republic of China
for technical competence in the field of
Electrical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 27th day of May 2025.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 6798.01
Valid to April 30, 2027 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Other Locations
1 other site in this organization
Labs with overlapping accredited scope in China
- WALTEK TESTING GROUP CO.,DongguanA2LAShares 3 accredited test methodsANSI C63.10:2013ANSI C63.4:2014AS CISPR 11
- DEKRA Testing and Certification (Shanghai)ShanghaiA2LAShares 2 accredited test methodsANSI C63.10:2013ANSI C63.4:2014
- EMTEK (Shenzhen) Co.,Shenzhen, GuangdongA2LAShares 2 accredited test methodsANSI C63.10:2013ANSI C63.4:2014
- Intertek Testing Services Shenzhen Ltd., Guangzhou BranchGuangzhou, GuangdongA2LAShares 2 accredited test methodsANSI C63.10:2013ANSI C63.4:2014
- MRT Technology (Suzhou) Co.,Suzhou, JiangsuA2LAShares 2 accredited test methodsANSI C63.10:2013ANSI C63.4:2014
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.