What this lab is accredited for
Our reading of the DAKKS scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 9 standard numbers and the 9 official names we hold. When no standard matches, it searches the method text of every scope line.
EN 27888Water quality - Determination of electrical conductivity
ISO 5667-3Water quality - Sampling - Part 3: Preservation and handling of water samples
ISO 5667-5Water quality - Sampling - Part 5: Guidance on sampling of drinking water from treatment works and piped distribution systems
ISO 7899-2Water quality - Detection and enumeration of intestinal enterococci - Part 2: Membrane filtration method
ISO 9308-1Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 1: Membrane filtration method for waters with low bacterial background flora
ISO 10523Water quality - Determination of pH
ISO 11731Water quality - Enumeration of Legionella
ISO 16266Water quality - Detection and enumeration of Pseudomonas aeruginosa - Method by membrane filtration
ISO 19458Water quality - Sampling for microbiological analysis
DIN EN ISO 9308 -1 2017 -09; DIN EN 27888 1993 -11; TrinkwV §43 Absatz (3); DIN EN ISO 10523 (C5) 2012 -04; DIN EN ISO 11731 2019 -03; UBA Empfehlung 18. Dezember 2018 Aktualisierung Dezember 2022 (Bundesgesundheitsblatt 2023 S. 224)
DIN EN ISO 9308 -1 2017 -09 Eisen nicht belegt Elektrische Leitfähigkeit DIN EN 27888 1993 -11 Färbung nicht belegt Geruch nicht belegt Geschmack nicht belegt Koloniezahl bei 22; DIN EN ISO 10523; DIN EN ISO 11731 2019 -03 UBA Empfehlung 18; ISO 9308 -1 2017 -09 Eisen nicht belegt Elektrische Leitfähigkeit DIN EN 27888 1993 -11 Färbung nicht belegt Geruch nicht belegt Geschmack nicht belegt Koloniezahl bei 22; ISO 10523
DIN EN ISO 5667 -3; DIN EN ISO 19458 2006-12 Wasserbeschaffenheit - Probenahme für mikrobiologische Untersuchungen UBA Empfehlung 18; DIN EN ISO 9308 -1 2017 -09 Intestinale Enterokokken DIN EN ISO 7899 -2 2000 -11; DIN EN ISO 9308 -1 2017 -09 Intestinale Enterokokken DIN EN ISO 7899 -2 2000 -11 Pseudomonas aeruginosa DIN EN ISO 16266 2008 -05; ISO 5667 -3
DIN ISO 5667-5; DIN EN ISO 19458; DIN EN ISO 9308-1; DIN EN ISO 7899-2; DIN EN ISO 16266
Read from the scope as published by DAKKS. Register refreshed 2026-11-06.
Scope as published by DAKKS
8 lines
ISO/IEC 17025
ActiveD-PL-13452-02-00
Accredited scope, certificate D-PL-13452-02-00
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | DIN EN ISO/IEC 17025:2018 | Water | - |
| 2 | DIN EN ISO 5667 -3; DIN EN ISO 19458 2006-12 Wasserbeschaffenheit - Probenahme für mikrobiologische Untersuchungen UBA Empfehlung 18; DIN EN ISO 9308 -1 2017 -09 Intestinale Enterokokken DIN EN ISO 7899 -2 2000 -11; DIN EN ISO 9308 -1 2017 -09 Intestinale Enterokokken DIN EN ISO 7899 -2 2000 -11 Pseudomonas aeruginosa DIN EN ISO 16266 2008 -05; ISO 5667 -3 | Water | - |
| 3 | DIN EN ISO 9308 -1 2017 -09 Eisen nicht belegt Elektrische Leitfähigkeit DIN EN 27888 1993 -11 Färbung nicht belegt Geruch nicht belegt Geschmack nicht belegt Koloniezahl bei 22; DIN EN ISO 10523; DIN EN ISO 11731 2019 -03 UBA Empfehlung 18; ISO 9308 -1 2017 -09 Eisen nicht belegt Elektrische Leitfähigkeit DIN EN 27888 1993 -11 Färbung nicht belegt Geruch nicht belegt Geschmack nicht belegt Koloniezahl bei 22; ISO 10523 | - | - |
| 4 | EN 1 | Water | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
ISO/IEC 17025
ActiveD-PL-13452-02-01
Accredited scope, certificate D-PL-13452-02-01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | DIN EN ISO/IEC 17025:2018 | Roh- und Trinkwasser | - |
| 2 | DIN ISO 5667-5; DIN EN ISO 19458; DIN EN ISO 9308-1; DIN EN ISO 7899-2; DIN EN ISO 16266 | Trinkwasser | - |
| 3 | DIN EN ISO 9308 -1 2017 -09; DIN EN 27888 1993 -11; TrinkwV §43 Absatz (3); DIN EN ISO 10523 (C5) 2012 -04; DIN EN ISO 11731 2019 -03; UBA Empfehlung 18. Dezember 2018 Aktualisierung Dezember 2022 (Bundesgesundheitsblatt 2023 S. 224) | Trinkwasser | - |
| 4 | - | TrinkwasserShow page textExtracted from the scope document; tables may not line up. View scope for the original. Anlage zur Akkreditierungsurkunde D-PL-13452-02-01
Gültig ab: 30.12.2025
Ausstellungsdatum: 30.12.2025 Seite 4 von 4
ANLAGE 4: ANFORDERUNGEN AN TRINKWASSER IN BEZUG AUF RADIOAKTIVE STOFFE
nicht belegt
PARAMETER, DIE NICHT IN DEN ANLAGEN 1 BIS 4 DER TRINKWASSERVERORDNUNG ENTHALTEN SIND
Weitere periodische Untersuchungen
nicht belegt
Die Akkreditierung ersetzt nicht das Anerkennungs- oder Zulassungsverfahren der zuständigen
Behörde nach § 40 Absatz (2) TrinkwV.
Verwendete Abkürzungen:
DIN Deutsches Institut für Normung e.V.
EN Europäische Norm
IEC International Electrotechnical Commission – Internationale Elektrotechnische Kommission
ISO International Organization for Standardization – Internationale Organisation für Normung
UBA Umweltbundesamt | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Germany
- Chemisches und mikrobiologisches Institut UEGWetzlar · ~396 kmDAKKSShares 4 accredited methods and materialsEN ISO 10523EN ISO 5667-3en 1
- SGS Analytics GermanyFellbach · ~501 kmDAKKSShares 4 accredited methods and materialsEN ISO 10523EN ISO 5667-3en 1
- Institut Kirchhoff BerlinBerlin · ~6 kmDAKKSShares 3 accredited methods and materialsEN ISO 10523en 1Water
- IfP Privates Institut für ProduktqualitätBerlin · ~21 kmDAKKSShares 3 accredited methods and materialsEN ISO 10523EN ISO 5667-3Water
- IHU Geologie und Analytik Gesellschaft für Ingenieur-, Hydro- und Umweltgeologie mbHStendal · ~98 kmDAKKSShares 3 accredited methods and materialsEN ISO 10523en 1Water
Accreditation data refreshed from the DAKKS register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.