Edmunds Gages
45 Spring Lane, 06032, Farmington, CT, United States
Visit website- Scope lines
- 3
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 3 scope lines.
A2LA certificate 1198.01 · 3 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1198.01) 9/27/2024 Page 1 of 2
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
EDMUNDS GAGES
45 Spring Lane
Farmington, CT 06032
John Wilkie Phone: 860 677 2813
CALIBRATION
Valid To: December 31, 2026 Certificate Number: 1198.01
In recognition of the successful completion of the A2LA evaluation process (including an assessment of
the organization’s compliance with A2LA’s Calibration Program Requirements), accreditation is granted
to this laboratory to perform the following calibrations
1, 5:
I. Dimensional
Parameter
Range3
CMC2, 3, 4 (±)
Comments
Length 1D (Custom
Reference Masters)
Up to 12 in
(25 + 1.3L) µin
(28 + 1.0L) µin
Surface plate, gage
blocks, gage
amplifier
Surface plate,
height master, gage
amplifier
Ring Gages (Cylindrical
Measure of Diameters)
(0.040 to 18) in
(0.040 to 13) in
(9 + 1.3D) µin
(14 + 1.6D) µin
Mechanical
comparison to
master gage blocks
ULM (universal
length measuring)
comparator
Master Discs and Plug
Gages (Cylindrical
Measure of Diameters)
(0.040 to 18) in
(0.040 to 13) in
(9 + 1.3D) µin
(14 + 1.6D) µin
Mechanical
comparison to
master gage blocks
ULM (universal
length measuring)
comparator | 0.04 to 18 in |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1198.01) 9/27/2024 Page 2 of 2
Parameter
Range3
CMC2, 3, 4 (±)
Comments
Ring Gages (Cylindrical
Measure of Taper)
(0.50 to 5) in
(21 + 6.0D) µin
Mechanical
comparison to
master gage blocks
Master Discs and Plug
Gages (Cylindrical
Measure of Taper)
(0.50 to 5) in
(21 + 6.0D) µin
Mechanical
comparison to
master gage blocks
Gage Blocks
Up to 20 in
(4 + 1.0L) µin
Mechanical
comparison to
master gage blocks
_______________________________________________________________________
1 This laboratory offers commercial calibration services.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
measurements of nearly ideal measurement standards or n early ideal measuring equipment. CMCs
represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using
a coverage factor of k = 2. The actual measurement uncertainty of a specific measurement performed by
the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences
from the circumstances of the specific calibration.
3 Arithmetic conversion to metric units (1 inch to 25.4 millimeter) performed when appropriate.
4 In the statement of CMC, L is the numerical value of the nominal length of the device expressed in inches;
D is the numerical value of the nominal diameter of the device in inches.
5 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
EDMUNDS GAGES
Farmington, CT
for technical competence in the field of
Calibration
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements
for the competence of testing and calibration laboratories. This laboratory also meets R205 – Specific Requirements: Calibration
Laboratory Accreditation Program. This accreditation demonstrates technical competence for a defined scope and the
operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 27th day of September 2024.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 1198.01
Valid to December 31, 2026 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.