Registers refreshed 2026-11-20.See refresh dates
United States

Edmunds Gages

45 Spring Lane, 06032, Farmington, CT, United States

Visit website
A2LA 1198.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
3
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 3 scope lines.

A2LA certificate 1198.01 · 3 lines

LineMethodMatrixRange
1--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1198.01) 9/27/2024 Page 1 of 2 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 EDMUNDS GAGES 45 Spring Lane Farmington, CT 06032 John Wilkie Phone: 860 677 2813 CALIBRATION Valid To: December 31, 2026 Certificate Number: 1198.01 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 5: I. Dimensional Parameter Range3 CMC2, 3, 4 (±) Comments Length 1D (Custom Reference Masters) Up to 12 in (25 + 1.3L) µin (28 + 1.0L) µin Surface plate, gage blocks, gage amplifier Surface plate, height master, gage amplifier Ring Gages (Cylindrical Measure of Diameters) (0.040 to 18) in (0.040 to 13) in (9 + 1.3D) µin (14 + 1.6D) µin Mechanical comparison to master gage blocks ULM (universal length measuring) comparator Master Discs and Plug Gages (Cylindrical Measure of Diameters) (0.040 to 18) in (0.040 to 13) in (9 + 1.3D) µin (14 + 1.6D) µin Mechanical comparison to master gage blocks ULM (universal length measuring) comparator
0.04 to 18 in
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1198.01) 9/27/2024 Page 2 of 2 Parameter Range3 CMC2, 3, 4 (±) Comments Ring Gages (Cylindrical Measure of Taper) (0.50 to 5) in (21 + 6.0D) µin Mechanical comparison to master gage blocks Master Discs and Plug Gages (Cylindrical Measure of Taper) (0.50 to 5) in (21 + 6.0D) µin Mechanical comparison to master gage blocks Gage Blocks Up to 20 in (4 + 1.0L) µin Mechanical comparison to master gage blocks _______________________________________________________________________ 1 This laboratory offers commercial calibration services. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine measurements of nearly ideal measurement standards or n early ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific measurement performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Arithmetic conversion to metric units (1 inch to 25.4 millimeter) performed when appropriate. 4 In the statement of CMC, L is the numerical value of the nominal length of the device expressed in inches; D is the numerical value of the nominal diameter of the device in inches. 5 This scope meets A2LA’s P112 Flexible Scope Policy.
3

Extracted from the scope document; tables may not line up. View scope for the original.

For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation. Accredited Laboratory A2LA has accredited EDMUNDS GAGES Farmington, CT for technical competence in the field of Calibration This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This laboratory also meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 27th day of September 2024. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 1198.01 Valid to December 31, 2026

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

45 Spring Lane, Farmington, CT, 06032, US

41.71982, -72.83204

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.