TECNOLAB della Dott.ssa Serino Caterina
Via delle Lenticchie, 20/22, 70022, Altamura, Italy
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at TECNOLAB della Dott.ssa Serino Caterina?
Claim this profile to keep it accurate.
Register record
- ACCREDIARefreshed
- 00533Active
Certificates and scope
1ISO/IEC 17025
Active00533
Accredited scope, certificate 00533
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | chemical | ISO 11731:2017; APAT CNR IRSA 3020 Man 29 2003; UNI EN ISO 6222:2001; UNI EN ISO 9308-1:2017; ISO 14189:2013; UNI EN ISO 7899-2:2003; UNI EN ISO 16266:2008; EPA 5030C 2003; EPA 8260D 2018 | Drinking water | - |
| 2 | chemical | EPA 5030C 2003; EPA 8260D 2018; UNI EN ISO 10304-1:2009; APAT CNR IRSA 4030 A2 Man 29 2003; APAT CNR IRSA 5170 Man 29 2003; UNI EN ISO 15587-2:2002; UNI EN ISO 11885:2009; UNI EN ISO 15587-1:2002; UNI EN ISO 17294-2:2023; ISO 15705:2002; UNI EN ISO 20236:2025; UNI EN 1484:1999 | Drinking water | - |
| 3 | chemical | EPA 3510C 1996; EPA 8270E 2018; ISO 21527-2:2008; UNI EN 13805:2014 + UNI EN ISO 17294-2:2023; UNI EN ISO 7932:2020; ISO 4832:2006; ISO 21528-2:2017; ISO 16649-2:2001; UNI EN ISO 4833-1:2022; UNI EN ISO 6579-1:2020; UNI EN ISO 6888-2:2023; UNI EN 13650:2002 + UNI EN ISO 11885:2009; MPI-01 rev. 6 2021; MPI-02 rev. 4 2025 | Soil | to 0.95 |
| 4 | chemical | EPA 3546 2007; EPA 8270E 2018 | Soil | - |
| 5 | chemical | EPA 5035A 2002; EPA 8260D 2018; UNI EN 12457-2:2004; UNI EN 15216:2021 | Soil | to 500 mg/L |
| 6 | - | APAT CNR IRSA 1030 Man 29 2003; ANPA RTI CTN_RIF 1/2000 Met 3; ANPA RTI CTN_RIF 1/2000 Met 2.2; UNI 10802:2023; ISO 18593:2018 | Waste water | - |
| 7 | chemical | - | Food products | - |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Italy
- BIOCHEMIE LAB S.r.l.Campi Bisenzio · ~554 kmACCREDIAShares 8 accredited methods and materialsAPAT CNR IRSA 1030 Man 29 2003EPA 3510C 1996EPA 5030C 2003
- INDAM LABORATORI SrL a socio unicoCastel Mella · ~733 kmACCREDIAShares 8 accredited methods and materialsAPAT CNR IRSA 1030 Man 29 2003EPA 3510C 1996EPA 5030C 2003
- S.C.A SERVIZI CONSULENZA ANALISI AMBIENTALIPisticci · ~48 kmACCREDIAShares 7 accredited methods and materialsAPAT CNR IRSA 1030 Man 29 2003EPA 3510C 1996EPA 5030C 2003
- CHIMILABRuffano · ~175 kmACCREDIAShares 7 accredited methods and materialsAPAT CNR IRSA 1030 Man 29 2003APAT CNR IRSA 3020 Man 29 2003EPA 3510C 1996
- LABORATORIO ANALISI DOTTOR VINCENZO SORCEMazzarino · ~439 kmACCREDIAShares 7 accredited methods and materialsAPAT CNR IRSA 1030 Man 29 2003EPA 3510C 1996EPA 5030C 2003
Accreditation data refreshed from the ACCREDIA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ACCREDIA entry linked above.